Interaction between phase shifting transformers installed in the tie-lines of interconnected power systems and automatic frequency controllers

FACTS devices like TCPAR can be used to regulate the power flow in tie-lines of interconnected power system. The transient state power flow occurring after power disturbances can be influenced by using TCPAR equipped with power regulator and frequency-based stabilizer. The analysis of a simple interconnected power system consisting of two power systems has shown that the control of TCPAR can force a good damping of both power swings and oscillations of local frequency. In the case of a larger interconnected power system consisting of more than two power systems, the influence of the control of TCPAR on damping can be more complicated. Strong damping of local frequency oscillations and power swings in one tie-line may cause larger oscillations in remote tie-lines and other systems. Hence the use of devices like TCPAR as tools for damping power swings and frequency oscillations in a large interconnected power system must be justified by detailed analysis of power system dynamics. In this paper, some results of time-domain simulations of a three-system area are presented. These results have proven that it is possible to obtain a good damping of tie-line power and frequency swings by optimizing the main parameters of TCPAR installed in tie-lines. The results have been confirmed by an eigenvalue analysis of linearized model of interconnected system consisting of three subsystems.

[1]  Peter W. Sauer,et al.  Power System Dynamics and Stability , 1997 .

[2]  Charles E. Fosha,et al.  Optimum Megawatt-Frequency Control of Multiarea Electric Energy Systems , 1970 .

[3]  D. Das,et al.  AGC of a hydrothermal system with thyristor controlled phase shifter in the tie-line , 2006, 2006 IEEE Power India Conference.

[4]  T. Mexia,et al.  Author ' s personal copy , 2009 .

[5]  Desire Rasolomampionona AGC and FACTS stabilization device coordination in interconnected power system control , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[6]  S. C. Tripathy,et al.  Effect of superconducting magnetic energy storage on automatic generation control considering governor deadband and boiler dynamics , 1992 .

[7]  Charles E. Fosha,et al.  The Megawatt-Frequency Control Problem: A New Approach Via Optimal Control Theory , 1970 .

[8]  S. C. Tripathy,et al.  Application of magnetic energy storage unit as load-frequency stabilizer , 1990 .

[9]  C. T. Pan,et al.  An Adaptive Controller for Power System Load-Frequency Control , 1989, IEEE Power Engineering Review.

[10]  R. R. Shoults,et al.  Multi-area adaptive LFC developed for a comprehensive AGC simulator , 1993 .

[11]  B. Bak-Jensen,et al.  Automatic generation control of multi-area power system with superconducting magnetic storage unit , 2001, 2001 IEEE Porto Power Tech Proceedings (Cat. No.01EX502).

[12]  D.D. Rasolomampionona,et al.  A modified power system model for AGC analysis , 2009, 2009 IEEE Bucharest PowerTech.

[13]  Ralph K. Cavin,et al.  An Optimal Linear Systems Approach to Load-Frequency Control , 1971 .

[14]  L. H. Fink,et al.  Understanding automatic generation control , 1992 .

[15]  Aysen Demiroren,et al.  Automatic Generation Control Using ANN Technique for Multi-Area Power System with SMES Units , 2004 .

[16]  Waree Kongprawechnon,et al.  A robust controller design of SSSC for stabilization of frequency oscillations in interconnected power systems , 2003 .

[17]  Om P. Malik,et al.  Variable-structure-system control applied to AGC of an interconnected power system , 1985 .

[18]  Om P. Malik,et al.  Automatic generation control of interconnected power systems using variable-structure controllers , 1983 .

[19]  S. Robak,et al.  Advanced modelling of generator - infinite busbar system including thyristor controlled phase shift transformer , 2003 .

[20]  L. K. Kirchmayer,et al.  Economic control of interconnected systems , 1959 .

[21]  Y. Mitani,et al.  Application of SMES coordinated with solid-state phase shifter to load frequency control , 1999, IEEE Transactions on Applied Superconductivity.

[22]  I. Ngamroo An optimization technique of robust load frequency stabilizer for superconducting magnetic energy storage , 2005 .

[23]  J. Carpentier,et al.  ‘To be or not to be modern’ that is the question for automatic generation control (point of view of a utility engineer) , 1985 .

[24]  Amit Patra,et al.  Effect of TCPS on oscillations in tie-power and area frequencies in an interconnected hydrothermal power system , 2007 .

[25]  S. C. Tripathy,et al.  Adaptive automatic generation control with superconducting magnetic energy storage in power systems , 1992 .