Evaluation of inter- and intrafraction organ motion during intensity modulated radiation therapy (IMRT) for localized prostate cancer measured by a newly developed on-board image-guided system.

PURPOSE To investigate prostatic organ motion at both setup and intrafraction using an onboard image-guided system. An intrafraction field-based repositioning method also was evaluated. MATERIALS AND METHODS A dual fluoroscopy with amorphous-silicon flat panel (DFFP) system was used for the three-dimensional registration of implanted markers in the prostate of eight organ-confined cancer patients planned for treatment with intensity modulated radiation therapy (IMRT). Day-to-day motion errors were quantified and intrafraction displacements of more than +/-1 mm were corrected. RESULTS Among 214 fractions and 565 system views, day-to-day mean magnitude of marker discrepancy +/- standard deviation (SD) was 1.76 +/- 1.4 mm, 3.14 +/- 1.6 mm, and 3.78 +/- 2.4 mm in the right-left, cranial-caudal, and anterior-posterior directions, respectively. The intrafractional mean magnitude +/- SD of marker displacement was 0.45 +/- 0.7 mm, 1.08 +/- 1.38 mm and 1.45 +/- 1.70 mm in the right-left, cranial-caudal, and anterior-posterior directions, respectively. Intrafraction corrected sessions (84/214) showed a median (range) of motion of 0.1 mm (-1.2 to 0.7 mm), -0.2 mm (-2.1 to 1.1 mm), and -0.2 mm (-1.7 to 2.0 mm) in the right-left, cranial-caudal, and anterior-posterior directions, respectively. CONCLUSION Motion uncertainty can be considerably decreased with daily use of the DFFP system. Reduced intrafraction organ motion clearly endorsed the value of the repositioning approach, allowing a safer dose escalation protocol.

[1]  Benjamin Movsas,et al.  Measurement of intrafractional prostate motion using magnetic resonance imaging. , 2002, International journal of radiation oncology, biology, physics.

[2]  C. Perez,et al.  Tumor control in definitive irradiation of localized carcinoma of the prostate. , 1986, International journal of radiation oncology, biology, physics.

[3]  Jan J W Lagendijk,et al.  Measurements and clinical consequences of prostate motion during a radiotherapy fraction. , 2002, International journal of radiation oncology, biology, physics.

[4]  G J Kutcher,et al.  Variation in prostate position quantitation and implications for three-dimensional conformal treatment planning. , 1997, International journal of radiation oncology, biology, physics.

[5]  H. Mostafavi,et al.  Development of real-time tumor tracking system with dmlc with dual X-ray fluoroscopy and amorphous silicon flat panel on the gantry of linear accelerator , 2002 .

[6]  J C Stroom,et al.  Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability. , 1999, International journal of radiation oncology, biology, physics.

[7]  D A Jaffray,et al.  A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets. , 1999, International journal of radiation oncology, biology, physics.

[8]  M. Zelefsky,et al.  Neoadjuvant androgen ablation prior to radiotherapy for prostate cancer: reducing the potential morbidity of therapy. , 1997, Urology.

[9]  D A Low,et al.  The influence of angular misalignment on fixed-portal intensity modulated radiation therapy. , 1997, Medical physics.

[10]  J H Siewerdsen,et al.  A performance comparison of flat-panel imager-based MV and kV cone-beam CT. , 2002, Medical physics.

[11]  Frieda Trichter,et al.  Prostate localization using transabdominal ultrasound imaging. , 2003, International journal of radiation oncology, biology, physics.

[12]  J A Antolak,et al.  Planning target volumes for radiotherapy: how much margin is needed? , 1999, International journal of radiation oncology, biology, physics.

[13]  G. Tsumatori,et al.  Focal, high dose, and fractionated modified stereotactic radiation therapy for lung carcinoma patients , 1998, Cancer.

[14]  M. Zelefsky,et al.  Neoadjuvant hormonal therapy improves the therapeutic ratio in patients with bulky prostatic cancer treated with three-dimensional conformal radiation therapy. , 1994, International journal of radiation oncology, biology, physics.

[15]  H Alasti,et al.  Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate. , 2001, International journal of radiation oncology, biology, physics.

[16]  M. V. van Herk,et al.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[17]  T Falco,et al.  Ultrasound imaging for external-beam prostate treatment setup and dosimetric verification. , 2002, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[18]  H Shirato,et al.  Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers. , 2000, International journal of radiation oncology, biology, physics.

[19]  H M Sandler,et al.  Localization of the prostatic apex for radiation therapy using implanted markers. , 1993, International journal of radiation oncology, biology, physics.

[20]  Hassan Mostafavi,et al.  Development of a new linear accelerator mounted with dual X-Ray fluoroscopy using amorphous silicon flat panel X-Ray sensors to detect a gold seed in a tumor at real treatment position , 2001 .

[21]  K L Lam,et al.  Automated localization of the prostate at the time of treatment using implanted radiopaque markers: technical feasibility. , 1995, International journal of radiation oncology, biology, physics.

[22]  P. Bergström,et al.  High-precision conformal radiotherapy (HPCRT) of prostate cancer--a new technique for exact positioning of the prostate at the time of treatment. , 1998, International journal of radiation oncology, biology, physics.

[23]  J Dudson,et al.  A feasibility study for megavoltage cone beam CT using a commercial EPID. , 1998, Physics in medicine and biology.

[24]  D. Gleason,et al.  Histologic Grading and Staging of Prostatic Carcinoma , 1981 .

[25]  G T Chen,et al.  Implications of 3-dimensional target shape and motion in aperture design. , 1996, Medical physics.

[26]  Lei Dong,et al.  Intrafraction prostate motion during IMRT for prostate cancer. , 2001, International journal of radiation oncology, biology, physics.

[27]  A. Porter,et al.  Prostate localization for the treatment planning of prostate cancer: a comparison of two techniques. , 1988, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[28]  W. Shipley The advantage of an X-ray visible marker of the prostatic apex. , 1993, International journal of radiation oncology, biology, physics.

[29]  T E Schultheiss,et al.  A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer. , 1999, International journal of radiation oncology, biology, physics.

[30]  A Brahme,et al.  Radiotherapeutic computed tomography with scanned photon beams. , 1987, International journal of radiation oncology, biology, physics.

[31]  R. Fraser,et al.  Chronic effects of therapeutic irradiation for localized prostatic carcinoma on anorectal function. , 2000, International journal of radiation oncology, biology, physics.

[32]  M. Zelefsky,et al.  Long term tolerance of high dose three‐dimensional conformal radiotherapy in patients with localized prostate carcinoma , 1999, Cancer.

[33]  D. Spelbring,et al.  The potential for normal tissue dose reduction with neoadjuvant hormonal therapy in conformal treatment planning for stage C prostate cancer. , 1995, International journal of radiation oncology, biology, physics.

[34]  M. V. van Herk,et al.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[35]  Jatinder R. Palta,et al.  Intensity-Modulated Radiation Therapy: The State of the Art , 2003 .

[36]  G J Kutcher,et al.  Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate. , 1997, International journal of radiation oncology, biology, physics.

[37]  T E Schultheiss,et al.  Daily CT localization for correcting portal errors in the treatment of prostate cancer. , 1998, International journal of radiation oncology, biology, physics.

[38]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[39]  J. Tsai,et al.  Implementation and utility of a daily ultrasound-based localization system with intensity-modulated radiotherapy for prostate cancer. , 2002, International journal of radiation oncology, biology, physics.

[40]  T. Mackie,et al.  Megavoltage CT on a tomotherapy system. , 1999, Physics in medicine and biology.

[41]  S L Schoeppel,et al.  Treatment planning issues related to prostate movement in response to differential filling of the rectum and bladder. , 1991, International journal of radiation oncology, biology, physics.

[42]  M van Herk,et al.  Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration. , 1995, International journal of radiation oncology, biology, physics.

[43]  M Goitein,et al.  Strategies for treating possible tumor extension: some theoretical considerations. , 1985, International journal of radiation oncology, biology, physics.

[44]  C. Pelizzari,et al.  Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy. , 1995, International journal of radiation oncology, biology, physics.

[45]  J. Crook,et al.  Prostate motion during standard radiotherapy as assessed by fiducial markers. , 1995, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[46]  Lei Dong,et al.  Experience of ultrasound-based daily prostate localization. , 2003, International journal of radiation oncology, biology, physics.

[47]  E. B. Butler,et al.  IMRT for prostate cancer: defining target volume based on correlated pathologic volume of disease. , 2003, International journal of radiation oncology, biology, physics.

[48]  J Pouliot,et al.  Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: a clinical study. , 1997, International journal of radiation oncology, biology, physics.