Transducer and base compliance alter the in situ 6 dof force measured from muscle during an isometric contraction in a multi-joint limb.

Although musculoskeletal models are commonly used, validating the muscle actions predicted by such models is often difficult. In situ isometric measurements are a possible solution. The base of the skeleton is immobilized and the endpoint of the limb is rigidly attached to a 6-axis force transducer. Individual muscles are stimulated and the resulting forces and moments recorded. Such analyses generally assume idealized conditions. In this study we have developed an analysis taking into account the compliances due to imperfect fixation of the skeleton, imperfect attachment of the force transducer, and extra degrees of freedom (dof) in the joints that sometimes become necessary in fixed end contractions. We use simulations of the rat hindlimb to illustrate the consequences of such compliances. We show that when the limb is overconstrained, i.e., when there are fewer dof within the limb than are restrained by the skeletal fixation, the compliances of the skeletal fixation and of the transducer attachment can significantly affect measured forces and moments. When the limb dofs and restrained dofs are matched, however, the measured forces and moments are independent of these compliances. We also show that this framework can be used to model limb dofs, so that rather than simply omitting dofs in which a limb does not move (e.g., abduction at the knee), the limited motion of the limb in these dofs can be more realistically modeled as a very low compliance. Finally, we discuss the practical implications of these results to experimental measurements of muscle actions.

[1]  Scott B. Nokleby,et al.  Wrench capabilities of planar parallel manipulators. Part I: Wrench polytopes and performance indices , 2008, Robotica.

[2]  M. U. Kurse,et al.  Computational Models for Neuromuscular Function , 2009, IEEE Reviews in Biomedical Engineering.

[3]  Dinesh K. Pai,et al.  Uncertainty and Compliance of Robot Manipulators with Applications to Task Feasibility , 1991, Int. J. Robotics Res..

[4]  S L Delp,et al.  A graphics-based software system to develop and analyze models of musculoskeletal structures. , 1995, Computers in biology and medicine.

[5]  Richard M. Murray,et al.  A Mathematical Introduction to Robotic Manipulation , 1994 .

[6]  Winter Da Biomechanics of human movement with applications to the study of human locomotion. , 1984 .

[7]  T. Nichols,et al.  Cat hindlimb muscles exert substantial torques outside the sagittal plane. , 1993, Journal of neurophysiology.

[8]  Will L. Johnson,et al.  A three-dimensional model of the rat hindlimb: musculoskeletal geometry and muscle moment arms. , 2008, Journal of biomechanics.

[9]  D. Pai Singularity, uncertainty and compliance of robot manipulators , 1988 .

[10]  Neville Hogan,et al.  Integrable Solutions of Kinematic Redundancy via Impedance Control , 1991, Int. J. Robotics Res..

[11]  Chris H. Mullens,et al.  Estimation of musculoskeletal models from in situ measurements of muscle action in the rat hindlimb , 2011, Journal of Experimental Biology.

[12]  Sang Wook Lee,et al.  Estimation of the effective static moment arms of the tendons in the index finger extensor mechanism. , 2008, Journal of biomechanics.

[13]  T. Richard Nichols,et al.  A Three-Dimensional Biomechanical Analysis of the Cat Ankle Joint Complex: I. Active and Passive Postural Mechanics , 1999 .

[14]  Joseph D. Towles,et al.  Quantification of fingertip force reduction in the forefinger following simulated paralysis of extensor and intrinsic muscles. , 2000, Journal of biomechanics.

[15]  Joseph D. Towles,et al.  The effect of percutaneous pin fixation of the interphalangeal joint on the thumb-tip force produced by the flexor pollicis longus: a cadaver study. , 2004, The Journal of hand surgery.

[16]  F. Valero-Cuevas,et al.  The fundamental thumb‐tip force vectors produced by the muscles of the thumb , 2004, Journal of Orthopaedic Research.

[17]  S. Giszter,et al.  Output Units of Motor Behavior: An Experimental and Modeling Study , 2000, Journal of Cognitive Neuroscience.