Gadolinium(III) ion selective sensor using a new synthesized Schiff's base as a sensing material

Abstract According to a solution study which showed a selective complexation between N , N′ -bis(methylsalicylidene)-2-aminobenzylamine (MSAB) and gadolinium ions, MSAB was used as a sensing element in construction of a gadolinium(III) ion selective electrode. Acetophenon (AP) was used as solvent mediator and sodium tetraphenyl borate (NaTPB) as an anion excluder. The electrode showed a good selectivity towards Gd(III) ions over a wide variety of cations tested. The constructed sensor displayed a Nernstian behavior (19.7 ± 0.3 mV/decade) in the concentration range of 1.0 × 10 − 6 to 1.0 × 10 − 2  mol L − 1 with detection limit of 5.0 × 10 − 7  mol L − 1 and a short response time (

[1]  Mohammad Reza Ganjali,et al.  Schiff's Bases and Crown Ethers as Supramolecular Sensing Materials in the Construction of Potentiometric Membrane Sensors , 2008, Sensors.

[2]  H. Zamani,et al.  Barium(II)-PVC Membrane Sensor Based on 4-4′-Methylenediantipyrine as a Neutral Carrier , 2008 .

[3]  M. Ganjali,et al.  A novel lutetium(III) PVC membrane sensor based on a new symmetric S–N Schiff's base for Lu(III) analysis in real sample , 2010 .

[4]  H. Zamani,et al.  Construction of Tb3+ PVC-MembraneElectrode Based on N,N’-Bis(pyrrolylmethylene)-2-aminobenzylamine , 2011 .

[5]  S. Kamata,et al.  Copper(II)-selective electrode using thiuram disulfide neutral carriers , 1988 .

[6]  M. Ganjali,et al.  A new ytterbium(III) PVC membrane electrode based on 6-methy-4-{[1-(1H-pyrrol-2-yl)methylidene]amino}-3-thioxo-3,4dihydro-1,2,4-triazin-5(2H)-one. , 2007, Talanta.

[7]  M. Ganjali,et al.  Determination of cerium(III) ions in soil and sediment samples by Ce(III) PVC-based membrane electrode based on 2,5-dioxo-4-imidazolidinyl , 2008 .

[8]  M. Ganjali,et al.  A novel Er(III) sensor based on a new hydrazone for the monitoring of Er(III) ions , 2006 .

[9]  H. Zamani,et al.  Application of N-Quinoline-2-carboxamido-8-aminoquinoline in Fabrication of a Ho(III)-PVC Membrane Sensor , 2011 .

[10]  R. Prasad,et al.  Metallo-tetraazaporphyrin based anion sensors: regulation of sensor characteristics through central metal ion coordination , 2004 .

[11]  M. Ganjali,et al.  Praseodymium analysis in aqueous solution by Pr3+–PVC membrane sensor based on N,N′-bis(4-hydroxysalicylidene)-1-3-phenylenediamine , 2011 .

[12]  M. Ganjali,et al.  Application of Novel Praseodymium (III) PVC‐Membrane Electrode for Determination of Pr(III) Ions in Soil and Sediment Samples , 2008 .

[13]  M. Nekoei,et al.  Terbium(III) Ion-Selective Electrochemical Sensor Based on Hematoporphyrin , 2009 .

[14]  M. Ganjali,et al.  Fabrication of an Iron–PVC Membrane Sensor Based on 5-Amino-3-Methyl-1-Phenyl-1H-Pyrazole-4-Carboxamide , 2009 .

[15]  M. Shamsipur,et al.  Novel gadolinium poly(vinyl chloride) membrane sensor based on a new S–N Schiff’s base , 2003 .

[16]  M. Ganjali,et al.  Construction of a highly selective PVC-based membrane sensor for Ce(III) ions , 2007 .

[17]  M. Reza Ganjali,et al.  Fabrication of a Praseodymium(III) PVC-Membrane Sensor Based on N′1,N′2-Bis(2-oxo-1,2-diphenylethylidene) ethanedihydrazide , 2009 .

[18]  Kazuhiro Manseki,et al.  Synthesis, structure, and magnetic properties of discrete d–f heterodinuclear complexes designed from tetrahedrally distorted [Cu(salabza)] (H2salabza = N,N′-bis(salicylidene)-2-aminobenzylamine) and [Ln(hfac)3] (Hhfac = 1,1,1,5,5,5-hexafluoroacetylacetone, Ln = Gd or Lu) , 2000 .

[19]  M. Ganjali,et al.  Determination of neodymium(III) ions in soil and sediment samples by a novel neodymium(III) sensor based on benzyl bisthiosemicarbazone , 2007 .

[20]  W. E. Morf,et al.  Catalysis of Ion Transfer by Tetraphenylborates in Neutral Carrier-Based Ion-Selective Electrodes , 1990 .

[21]  M. Ganjali,et al.  Quantitative monitoring of terbium ion by a Tb3+ selective electrode based on a new Schiff's base , 2011 .

[22]  H. Sharma,et al.  Potentiometric Sensor for Gadolinium(III) Ion Based on Zirconium(IV) Tungstophosphate as an Electroactive Material , 2009 .

[23]  M. Shamsipur,et al.  Thermodynamic study of the binding of hexathia-18-crown-6-tetraone with some transition and heavy metal ions in dimethyl sulfoxide solution , 1998 .

[24]  M. Ganjali,et al.  Construction of Tm3+-PVC membrane sensor based on 1-(2-thiazolylazo)-2-naphthol as sensing material , 2010 .

[25]  H. Zamani,et al.  Determination of Dysprosium(III) Ion in Soil and Sediment Samples by an Original Potentiometric Dysprosium(III) Membrane Sensor , 2008 .

[26]  Y. Umezawa,et al.  Selectivity coefficients for ion-selective electrodes: Recommended methods for reporting KA,Bpot values (Technical Report) , 1995 .

[27]  M. Ganjali,et al.  Fabrication of an iron(III) PVC-membrane sensor based on bis-benzilthiocarbohydrazide as a selective sensing material , 2009 .

[28]  M. Ganjali,et al.  Strontium PVC-membrane sensor based on 2-[(2-mercaptophenylimino)methyl]phenol , 2008 .

[29]  M. Ganjali,et al.  Determination of gadolinium(III) ions in soil and sediment samples by a novel gadolinium membrane sensor based on 6-methyl-4-{[1-(2-thienyl)methylidene]amino}3-thioxo-3,4-dihydro-1,2,4-triazin-5-(2H)-one. , 2007, Analytica chimica acta.

[30]  H. Zamani,et al.  Construction of Eu3+ Ion-Selective Electrode Based on 1,2-Diaminopropane-N,N,N',N'-tetraacetic acid , 2011 .

[31]  M. Ganjali,et al.  Neodymium(III)–PVC membrane sensor based on a new four dentate ionophore , 2011 .

[32]  Ernö Pretsch,et al.  Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics. , 1997, Chemical reviews.

[33]  Z. Pourghobati,et al.  Synthesis of a new triazine derived macrocycle and a thermodynamic study of its complexes with some transition and heavy metal ions in acetonitrile solution , 2000 .

[34]  M. Ganjali,et al.  Thulium(III) Sensor Based on a Derivative of Thiourea Doped in Polymeric Membrane , 2011 .

[35]  M. Ganjali,et al.  Synthesis of N′-(1-Pyridin-2-ylmethylene)-2-furohydrazide and Its Application in Construction of a Highly Selective PVC-Based Membrane Sensor for La(III) Ions , 2006, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[36]  M. Ganjali,et al.  A New Pentadentate S‐N Schiffs' Base as a Novel Ionophore in Construction of a Novel Gd(III) Membrane Sensor , 2005 .

[37]  H. Zamani,et al.  Samarium(III)-PVC-Membrane Sensor Based on Ethoxy-1-ethoxycarbonyl-1,2-dihydroquinoline , 2009 .

[38]  M. Ganjali,et al.  Ion recognition: application of symmetric and asymmetric schiff bases and their complexes for the fabrication of cationic and anionic membrane sensors to determine ions in real samples. , 2007, Combinatorial chemistry & high throughput screening.

[39]  Ashutosh Kumar Singh,et al.  Nano level detection of Cd(II) using poly(vinyl chloride) based membranes of Schiff bases. , 2009, Analytica chimica acta.

[40]  M. Shamsipur,et al.  Novel Gadolinium PVC-Based Membrane Sensor Based on Omeprazole as an Antibiotic , 2003 .

[41]  M. Ganjali,et al.  Fabrication of a highly selective and sensitive Gd(III)-PVC membrane sensor based on N-(2-pyridyl)-N′-(4-nitrophenyl)thiourea , 2007 .

[42]  Ashutosh Kumar Singh,et al.  Development of membrane electrodes for selective determination of some antiepileptic drugs in pharmaceuticals, plasma and urine , 2007, Analytical and bioanalytical chemistry.

[43]  M. Ganjali,et al.  Fabrication of a new samarium(III) ion-selective electrode based on 3-{[2-oxo-1(2h)-acenaphthylenyliden]amino}-2-thioxo -1,3-thiazolidin-4-one , 2007 .

[44]  M. Ganjali,et al.  Fabrication of a novel holmium(III) PVC membrane sensor based on 4-chloro-1,2-bis(2-pyridinecarboxamido)benzene as a neutral ionophore , 2007 .

[45]  H. Zamani Construction of Strontium PVC-Membrane Sensor Based on Salicylaldehyde Thiosemicarbazone , 2008 .

[46]  M. Ganjali,et al.  A New Europium(III) PVC Membrane Potentiometric Sensor Based on 4-(2-Hydroxybenzylideneamino)-6-methyl-3-thioxo-3,4-dihydro-1,2,4-triazin-5(2H)-one , 2007 .

[47]  M. Ganjali,et al.  Determination of terbium(III) ions in phosphate rock samples by a Tb3+–PVC membrane sensor based on N, N-Dimethyl-N′, N″-bis(4-methoxyphenyl)phosphoramidate , 2008 .

[48]  H. Zamani,et al.  Erbium(III) PVC Membrane Ion-Selective Sensor based on 4-(2-Thiazolylazo)resorcinal , 2009 .

[49]  M. Ganjali,et al.  Determination of Erbium Ions in Water Samples by a PVC Membrane Erbium-Ion Selective Electrode , 2010 .

[50]  M. Ganjali,et al.  A novel iron (III)-PVC membrane potentiomeric sensor based on N-(2-hydroxyethyl)ethylenediamine-N,N',N"-triacetic acid , 2008 .

[51]  H. Zamani PVC-Membrane Potentiometric Electrochemical Sensor Based on 2-(4-Oxopentan-2-ylideneamino)isoindoline-1,3-dione for Selective Determination of Holmium(III) , 2011 .

[52]  Richard P. Buck,et al.  Recommendations for nomenclature of ionselective electrodes (IUPAC Recommendations 1994) , 1994 .

[53]  M. Ganjali,et al.  Construction of barium (II) PVC membrane electrochemical sensor based on 3-deoxy-D-erythro-hexos-2-ulose bis (thiosemicarbazone) as a novel ionophore , 2010 .