Love wave biosensor for real-time detection of okadaic acid as DSP phycotoxin

This paper reports the detection of okadaic acid (OA) as a Diarrheic Shellfish Poisoning (DSP) toxin with an acoustic wave platform in real-time. According to the FDA, the threshold for safe consumption of shellfish is 20 μg of OA for 100 g of shellfish tissue. The high gravimetric sensitivity of Love wave acoustic devices allow, in liquid media, immuno-detection thanks to immobilized specific antibodies. The biosensor is composed of two lines, one for the test and one used as a reference. Sensitive films were deposited through a PolyDiMethylSiloxane (PDMS) microfluidic chip. On both lines, anti-okadaic acid antibodies (OA-Ab) and saturating agents were successively injected under continuous flow with controlled flow rate. On the test line, okadaic acid (OA) was injected while an unspecific peptide (6×Histidine, 6×His) was used on the control line. On both lines, polyclonal OA-Ab were re-injected a second time to reveal previously fixed OA on the test line. Measured frequency shifts were three times higher on test lines than on control lines. In these conditions, for only 2 μg of OA used for detection, the acoustic wave platform could detect DSP toxins with only 10 g of shellfish tissue.

[1]  J. Pillot,et al.  PDMS (Polydimethylsiloxane) Microfluidic Chip Molding for Love Wave Biosensor , 2009 .

[2]  R. Olson,et al.  A submersible imaging‐in‐flow instrument to analyze nano‐and microplankton: Imaging FlowCytobot , 2007 .

[3]  Geoffrey A. Codd,et al.  HARMFUL CYANOBACTERIA From mass mortalities to management measures , 2005 .

[4]  Roman Marin,et al.  Remote, subsurface detection of the algal toxin domoic acid onboard the Environmental Sample Processor: Assay development and field trials , 2009 .

[5]  Mary Jane Perry,et al.  In Situ Instrumentation , 2007 .

[6]  G. Doucette,et al.  Marine and Estuarine Harmful Algal Blooms: Impacts on Human and Animal Health , 2005 .

[7]  Mati Kahru,et al.  New approaches and technologies for observing harmful algal blooms , 2005 .

[8]  Dominique Rebière,et al.  Love-wave bacteria-based sensor for the detection of heavy metal toxicity in liquid medium. , 2010, Biosensors & bioelectronics.

[9]  Dmitri Ivnitski,et al.  Biosensors for detection of pathogenic bacteria , 1999 .

[10]  Dominique Rebière,et al.  A Love wave immunosensor for whole E. coli bacteria detection using an innovative two-step immobilisation approach. , 2007, Biosensors & bioelectronics.

[11]  María-Isabel Rocha-Gaso,et al.  Surface Generated Acoustic Wave Biosensors for the Detection of Pathogens: A Review , 2009, Sensors.

[12]  C. Dejous,et al.  High frequency microrheological measurements of PDMS fluids using saw microfluidic system , 2010 .

[13]  K. Flynn,et al.  Chemical and Physical Factors Influencing Toxin Content , 2006 .

[14]  R. O'Kennedy,et al.  Advances in biosensors for detection of pathogens in food and water , 2003 .