Reduction in VA rating of the Unified Power Quality Conditioner with superconducting fault current limiters

The paper deals with an optimized Unified Power Quality Conditioner (UPQC), which aims at the integration of series and shunt active power filters with minimum rating of the UPQC. In this paper analysis results of a combination the UPQC with a superconducting fault current limiter (SFCL) are presented. SFCL aids on reduction in VA rating of the UPQC with limiting the excessive current in the event of fault. The combination of electrical and thermal model of a designed resistive type SFCL is defined as a component in PSCAD/EMTDC simulations. The proposed scheme can compensate voltage sag and current harmonics at the point of common coupling (PCC) on power distribution systems. Through the results of several analyses and simulations carried out by PSCAD/EMTDC, this demonstrates the signification effect of the control by SFCL on rating reduction of the UPQC.

[1]  G. G. Karady Principles of fault current limitation by a resonant LC circuit , 1992 .

[2]  Valentin Navrapescu,et al.  Single-Phase Unified Power Quality Conditioner with Optimum Voltage Angle Injection for Minimum VA requirement , 2007, PESC 2007.

[3]  Liangzhen Lin,et al.  Application studies of superconducting fault current limiters in electric power systems , 2002 .

[4]  Y. Laumond,et al.  Towards the superconducting fault current limiter , 1991 .

[5]  S. Quaia,et al.  Reducing voltage sags through fault current limitation , 2001 .

[6]  Mathias Noe,et al.  Investigation of high-Tc bulk material for its use in resistive superconducting fault current limiters , 2001 .

[7]  R. Sharifi,et al.  An investigation on optimum volume of superconducting element of RSFCL considering harmonic generation , 2008, 2008 3rd IEEE Conference on Industrial Electronics and Applications.

[8]  M. Noe,et al.  Technical and economical benefits of superconducting fault current limiters in power systems , 1999, IEEE Transactions on Applied Superconductivity.

[9]  Xiaoming Zha,et al.  Unified Power Quality Conditioner (UPQC): the theory, modeling and application , 2000, PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409).

[10]  Mathias Noe,et al.  High-temperature superconductor fault current limiters: concepts, applications, and development status , 2007 .

[11]  Hirofumi Akagi,et al.  The unified power quality conditioner: the integration of series- and shunt-active filters , 1998 .

[12]  A. Y. Chikhani,et al.  Fault-current limiter with thyristor-controlled impedance , 1993 .

[13]  Ok-Bae Hyun,et al.  Stability analysis of a power system with superconducting fault current limiter installed , 2001 .

[14]  Hirofumi Akagi,et al.  A new power line conditioner for harmonic compensation in power systems , 1995 .

[15]  M. Kurrat,et al.  Thermal-Electric Simulations of Coated Conductors With a Variable Conductivity of the Buffer Layer , 2007, IEEE Transactions on Applied Superconductivity.

[16]  Toshiro Matsumura,et al.  A study on required volume of superconducting element for flux flow resistance type fault current limiter , 2003 .