The Hardware and Signal Processing Architecture of LabPET™, a Small Animal APD-Based Digital PET Scanner

The highly multiplexed analog processing front-end of current Positron Emission Tomography (PET) scanners yields high accuracy for timing but adds significant dead time and offers little flexibility for improvement. A new fully digital APD-based scanner architecture is proposed wherein nuclear pulses are sampled directly at the output of the Charge Sensitive Preamplifier (CSP) with one free-running ADC per channel. This approach offers the opportunity to explore new digital signal processing algorithms borrowed from other fields like command and control theory, as well as advanced heuristics such as neural networks. The analog front-end consists of a dedicated 0.18- mum, 16-channel CMOS charge sensitive preamplifier. Digitization is performed with off-the-shelf dual 8-bit analog-to-digital converters running at 45-MSPS. Digital processing is shared between a FPGA and a Digital Signal Processor (DSP), which can process the data from up to 64 parallel channels without dead time. The FPGA deals with the initial signal analysis for energy measurement and time stamping, while crystal identification is deferred to the DSP running computation-intensive recursive algorithms. The entire system is controlled serially through a Firewire link by a Graphic User Interface. The initial LabPETtrade implementation of the system is a dedicated small animal scanner holding up to 4608 APD channels at an averaged count rate of up to 10 000 events/s each.

[1]  G. Brandenburg,et al.  The data acquisition system of ClearPET neuro - a small animal PET scanner , 2006, IEEE Transactions on Nuclear Science.

[2]  R. Fontaine,et al.  System Integration of the LabPET Small Animal PET Scanner , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[3]  R. Fontaine,et al.  Time Determination of BGO-APD Detectors by Digital Signal Processing for Positron Emission Tomography , 2009, IEEE Transactions on Nuclear Science.

[4]  R. Fontaine,et al.  Crystal identification based on recursive-least-squares and least-mean-squares autoregressive models for small animal PET , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[5]  H. Murayama,et al.  The jPET-D4: imaging performance of the 4-layer depth-of-interaction PET scanner , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[6]  Barbara Y. Croft,et al.  Animal Models for imaging , 2003, Disease markers.

[7]  P. Kumar,et al.  Theory and practice of recursive identification , 1985, IEEE Transactions on Automatic Control.

[8]  R. Fontaine,et al.  Time Discrimination Techniques Using Artificial Neural Networks for Positron Emission Tomography , 2004, IEEE Transactions on Nuclear Science.

[9]  P. O'Connor,et al.  Front-end electronics for the RatCAP mobile animal PET scanner , 2004, IEEE Transactions on Nuclear Science.

[10]  Sibylle Ziegler,et al.  An analog signal processing ASIC for a small animal LSO–APD PET tomograph , 2006 .

[11]  M. Desco,et al.  New embedded digital front-end for high resolution PET scanner , 2006, IEEE Transactions on Nuclear Science.

[12]  R. Fontaine,et al.  Design and performance of 0.18-/spl mu/m CMOS charge preamplifiers for APD-based PET scanners , 2004, IEEE Transactions on Nuclear Science.

[13]  R. Fontaine,et al.  Real Time Implementation of a Wiener Filter Based Crystal Identification Algorithm , 2008, IEEE Transactions on Nuclear Science.

[14]  R. Lecomte,et al.  Physical characterization of the LabPET™ LGSO and LYSO scintillators , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[15]  Roger N. Gunn,et al.  Pharmacological constraints associated with positron emission tomographic scanning of small laboratory animals , 1998, European Journal of Nuclear Medicine.

[16]  R. Fontaine,et al.  Real Time Implementation of a Wiener Filter Based Crystal Identification Algorithm for Photon Counting CT Imaging , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[17]  C. Bohm,et al.  A flexible data acquisition module for high resolution PET camera , 2005, 14th IEEE-NPSS Real Time Conference, 2005..

[18]  Lennart Ljung,et al.  Theory and Practice of Recursive Identification , 1983 .

[19]  R. Fontaine,et al.  Digital signal processing applied to crystal identification in Positron Emission Tomography dedicated to small animals , 2007 .

[20]  R. Fontaine,et al.  Crystal Identification Based on Recursive-Least-Squares and Least-Mean-Squares Auto-Regressive Models for Small Animal Pet , 2008, IEEE Transactions on Nuclear Science.

[21]  Thomas K. Lewellen,et al.  Simplified FPGA-based data acquisition system for PET , 2002 .

[22]  R. Fontaine,et al.  System Architecture of the LabPET Small Animal PET Scanner , 2008, IEEE Transactions on Nuclear Science.

[23]  R. Fontaine,et al.  Experimental results of identification and vector quantization algorithms for DOI measurement in digital PET scanners with phoswich detectors , 2004, IEEE Symposium Conference Record Nuclear Science 2004..