Comparative Analysis of DSOGI-PLL& Adaptive Frequency Loop-PLL for Voltage and Frequency control of PMSG-BESS based Hybrid Standalone WECS

3-phase PLL (phase-locked-loop) are the key elements for frequency & phase estimation of a balanced/disturbance voltage of the power system subjected to disturbances. Accurate measurement of generator speed in wind energy conversion system (WECS) is the most crucial task and it is worsening in disturbed voltage states. A dual-second-order-generalized-integrator (DSOGI)-PLL based control for load side bidirectional voltage source converter (VSC) is discussed in this paper for standalone hybrid variable speed WECS comprising of permanent magnet synchronous generator (PMSG) and & battery energy storage system (BESS). DSOGI-PLL based control scheme is presented here for voltage and frequency control. A MATLAB/Simulink-model is prepared for the system under study and a detailed simulation is performed. The effectiveness of the controller under study is checked by comparing it with Adaptive frequency loop-PLL based controller for different working conditions; like variable wind velocity, load variation, load disturbances, and faults. It is concluded from the simulation study that DSOGI-PLL gives comparative better performance during transient like: fault and unbalanced/disturbed voltage conditions. DSOGI-PLL removes the harmonics and disturbances from the signal (dq-axis component generation) as compared to Adaptive frequency loop-PLL. Proposed controller provides excellent control for VSC. BESS is able to perform load balancing during variations in wind-velocity and load.

[1]  Marco Liserre,et al.  New Positive-sequence Voltage Detector for Grid Synchronization of Power Converters under Faulty Grid Conditions , 2006 .

[2]  P. D. Chandana Perera,et al.  Sensorless Control of Permanent-Magnet Synchronous Motor Drives , 2002 .

[3]  M. Liserre,et al.  Synchronization methods for three phase distributed power generation systems - An overview and evaluation , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[4]  Gabriel Garcera,et al.  Comparative Study of Speed Estimators Applied to Wind Turbine with Harmonic Distortion in the Currents and the Voltages , 2010 .

[5]  P. K. Jain,et al.  Problems of Startup and Phase Jumps in PLL Systems , 2012, IEEE Transactions on Power Electronics.

[6]  Vinod John,et al.  Analysis of Bandwidth–Unit-Vector-Distortion Tradeoff in PLL During Abnormal Grid Conditions , 2013, IEEE Transactions on Industrial Electronics.

[7]  J. Doval-Gandoy,et al.  Grid-synchronization methods for power converters , 2009, 2009 35th Annual Conference of IEEE Industrial Electronics.

[8]  Md. Shamim Reza,et al.  Grid voltage offset and harmonics rejection using second order generalized integrator and kalman filter technique , 2012, Proceedings of The 7th International Power Electronics and Motion Control Conference.

[9]  Mehmet Emin Meral,et al.  DSOGI-PLL Based Power Control Method to Mitigate Control Errors Under Disturbances of Grid Connected Hybrid Renewable Power Systems , 2018 .

[10]  V. Vanitha,et al.  Power generation using Permanent Magnet Synchronous Generator (PMSG) Based Variable Speed Wind Energy Conversion System (WECS): An Overview , 2018 .

[11]  Sabha Raj Arya,et al.  Variable step learning based control algorithm for power quality in PMSG based power generation system , 2016, 2016 IEEE 7th Power India International Conference (PIICON).

[12]  Juan C. Vasquez,et al.  Three-Phase PLLs: A Review of Recent Advances , 2017, IEEE Transactions on Power Electronics.

[13]  Kalpeshkumar R. Patil,et al.  Modified dual second-order generalised integrator FLL for synchronization of a distributed generator to a weak grid , 2016, 2016 IEEE 16th International Conference on Environment and Electrical Engineering (EEEIC).

[14]  V.G. Agelidis,et al.  Offset rejection for PLL based synchronization in grid-connected converters , 2008, 2008 Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition.