Voltage intensity based non-invasive blood glucose monitoring

Diabetes is one among the supreme health challenges of the current century. Most common method for estimation of blood glucose concentration is using glucose meter. The process involves pricking the finger and extracting the blood along with chemical analysis being done with the help of disposable test strips. Non-invasive method for glucose estimation promotes regular testing, adequate control and reduction in health care cost. The proposed method makes use of a near infrared sensor for determination of blood glucose. Near-infrared (NIR) is sent through the fingertip, before and after blocking the blood flow by making use of a principle called occlusion. By analyzing the variation in voltages received after reflection in both the cases with the dataset, the current diabetic condition as well as the approximate glucose level of the individual is predicted. The results obtained are being validated with glucose meter readings and statistical analysis of the readings where done. Analysis shows that the bias as well as the standard deviation decreases as the glucose concentration increases. The obtained result is then communicated with a smart phone through Bluetooth for further communication with the doctor.

[1]  Kevin H. Hazen,et al.  Comparison of glucose concentration in interstitial fluid, and capillary and venous blood during rapid changes in blood glucose levels. , 2001, Diabetes technology & therapeutics.

[2]  V. Ashok,et al.  A Novel Method for Blood Glucose Measurement by Noninvasive Technique Using Laser , 2012 .

[3]  W Thomas,et al.  Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid. , 1997, The Journal of laboratory and clinical medicine.

[4]  A. Bolz,et al.  Design of a Compact Multi-Sensor System for Non-Invasive Glucose Monitoring Using Optical Spectroscopy , 2012 .

[5]  Harel Primack,et al.  Continuous Noninvasive Glucose Monitoring Technology Based on “Occlusion Spectroscopy” , 2007, Journal of diabetes science and technology.

[6]  Xiaohao Wang,et al.  Non-Invasive Glucose Measurement by Use of Metabolic Heat Conformation Method , 2008, Sensors.

[7]  V.ashok,et al.  A Novel Method for Blood Glucose Measurement by Noninvasive Technique Using Laser , 2011 .

[8]  Dr. R. K. Prasad Non Invasive Blood Glucose Measurement using NIR technique based on occlusion spectroscopy , 2011 .

[9]  Anna Gina Perri,et al.  DESIGN OF A DIELECTRIC SPECTROSCOPY SENSOR FOR CONTINUOUS AND NON -INVASIVE BLOOD GLUCOSE MONITORING , 2012 .

[10]  M A Arnold,et al.  Noninvasive blood glucose measurements by near-infrared transmission spectroscopy across human tongues. , 2000, Diabetes technology & therapeutics.

[11]  Richard Barnett Diabetes , 1904, The Lancet.