The commercial availability of inductively coupled plasma-mass spectrometry technology (ICP-MS) has presented the opportunity to measure the boron concentrations and isotope ratios in a large number of samples with minimal sample preparation. A typical analytical sequence for fecal samples consists of 25 acid blanks, 1 digestion blank, 5 calibration solutions, 4 standard reference material solutions, 10 samples, and 4 natural abundance bias standards. Boron detection limits (3 x 1 sigma) for acid blanks are 0.11 ppb for 10B, and 0.40 ppb for 11B. Isotope ratios were measured in fecal samples with 20 to 50 ppb boron with < 2% relative standard deviation. Rapid washout and minimal memory effects were observed for a 50 ppb beryllium internal standard, but a 200 ppb boron biological sample had a 1.0 ppb boron memory after a 6-min washout. Boron isotope ratios in geological materials are highly variable; apparently this variability is reflected in plants of a fixed natural abundance value for boron requires that a natural abundance ratio be determined for each sample or related data set. The natural abundance variability also prevents quantitation and calculation of isotope dilution by instrument-supplied software. To measure boron transport in animal systems, 20 micrograms of 10B were fed to a fasted rat. During the 3 days after a 10B oral dose, 95% of the 10B was recovered from the urine and 4% from the feces. Urinary isotope ratios, 11B/10B, changed from a natural abundance of 4.1140 to an enriched value of 0.95077, a 77% change.(ABSTRACT TRUNCATED AT 250 WORDS)
[1]
P. Tothill,et al.
Inductively coupled plasma mass spectrometry for the determination of platinum in animal tissues and a comparison with atomic absorption spectrometry
,
1990
.
[2]
P. Nirel,et al.
Plasma source mass spectrometry (ICP-MS) application to multi-element analysis in environmental samples : a practical evaluation
,
1991
.
[3]
M. Shima.
GEOCHEMICAL STUDY OF BORON ISOTOPES
,
1963
.
[4]
R. Houk,et al.
A Study of Internal Standardization in Inductively Coupled Plasma-Mass Spectrometry
,
1987
.
[5]
R. Houk,et al.
Suppression of analyte signal by various concomitant salts in inductively coupled plasma mass spectrometry
,
1986
.
[6]
R. A. Vanderpool,et al.
Boron isotope ratios in commercial produce and boron-10 foliar and hydroponic enriched plants
,
1992
.
[7]
G. Horlick,et al.
Background Spectral Features in Inductively Coupled Plasma/Mass Spectrometry
,
1986
.
[8]
A. L. Gray,et al.
Handbook of Inductively Coupled Plasma Mass Spectrometry
,
1991
.
[9]
D. Grégoire,et al.
Determination of boron isotope ratios in geological materials by inductively coupled plasma mass spectrometry
,
1987
.