One-Port Electronic Detection Strategies for Improving Sensitivity in Piezoelectric Resonant Sensor Measurements

This paper describes a one-port mechanical resonance detection scheme utilized on a piezoelectric thin film driven silicon circular diaphragm resonator and discusses the limitations to such an approach in degenerate mode mass detection sensors. The sensor utilizes degenerated vibration modes of a radial symmetrical microstructure thereby providing both a sense and reference mode allowing for minimization of environmental effects on performance. The circular diaphragm resonator was fabricated with thickness of 4.5 µm and diameter of 140 µm. A PZT thin film of 0.75 µm was patterned on the top surface for the purposes of excitation and vibration sensing. The device showed a resonant frequency of 5.8 MHz for the (1, 1) mode. An electronic interface circuit was designed to cancel out the large static and parasitic capacitance allowing for electrical detection of the mechanical vibration thereby enabling the frequency split between the sense and reference mode to be measured accurately. The extracted motional current, proportional to the vibration velocity, was fed back to the drive to effectively increase the Q factor, and therefore device sensitivity, by more than a factor of 8. A software phase-locked loop was implemented to automatically track the resonant frequencies to allow for faster and accurate resonance detection. Results showed that by utilizing the absolute mode frequencies as an indication of sensor temperature, the variation in sensor temperature due to the heating from the drive electronics was accounted for and led to an ultimate measurement sensitivity of 2.3 Hz.

[1]  M. Blencowe Nanoelectromechanical systems , 2005, cond-mat/0502566.

[2]  R. Lucklum,et al.  Interface circuits for quartz-crystal-microbalance sensors , 1999 .

[3]  H. Tilmans Equivalent circuit representation of electromechanical transducers: I. Lumped-parameter systems , 1996 .

[4]  R. Burnett,et al.  Electronic Detection Strategies for a MEMS-Based Biosensor , 2013, Journal of Microelectromechanical Systems.

[5]  L. H. Ting,et al.  Active compensation of op-amp circuits , 1982 .

[6]  Ulrich Schmid,et al.  Quality-factor amplification in piezoelectric MEMS resonators applying an all-electrical feedback loop , 2011 .

[7]  Craig A. Rogers,et al.  An Impedance Method for Dynamic Analysis of Active Material Systems , 1997 .

[8]  C. M. Li,et al.  Micro-piezoelectric immunoassay chip for simultaneous detection of Hepatitis B virus and α-fetoprotein , 2011 .

[9]  Tae Song Kim,et al.  Effect of mass and stress on resonant frequency shift of functionalized Pb(Zr0.52Ti0.48)O3 thin film microcantilever for the detection of C-reactive protein , 2004 .

[10]  R. C. Colwell,et al.  THE VIBRATION OF CIRCULAR PLATES. , 1940, Science.

[11]  Alun Harris,et al.  The fabrication, characterization and testing of a MEMS circular diaphragm mass sensor , 2008 .

[12]  Jong Chul Kim,et al.  A highly stable quartz crystal microbalance sensor and its application to water vapor measurements , 2006 .

[13]  D. Tomboulian,et al.  On Piezoelectricity , 2022 .

[14]  Zhongxu Hu,et al.  Design, fabrication and characterization of a piezoelectric MEMS diaphragm resonator mass sensor , 2013 .

[15]  Susan Trolier-McKinstry,et al.  Temperature dependence of the piezoelectric response in lead zirconate titanate films , 2004 .

[16]  Jung Ho Park,et al.  In-situ quantitative analysis of a prostate-specific antigen (PSA) using a nanomechanical PZT cantilever. , 2004, Lab on a chip.

[17]  A. Slavin Stabilization of sample temperature in a surface-science vacuum chamber to 0.03 K and quartz-crystal microbalance frequency to 0.06 Hz over 0.5 h. , 2010, The Review of scientific instruments.

[18]  T. Gabrielson Mechanical-Thermal Noise in Acoustic and Vibration sensors , 1993 .

[19]  Craig A. Rogers,et al.  Structural modal analysis using collocated piezoelectric actuator/sensors: an electromechanical approach , 1994, Smart Structures.

[20]  Geunbae Lim,et al.  A self-excited micro cantilever biosensor actuated by PZT using the mass micro balancing technique , 2006 .

[21]  H. Seidel,et al.  Piezoelectric micro-scale tuning fork resonators for sensing applications , 2011, 2011 16th International Solid-State Sensors, Actuators and Microsystems Conference.

[22]  Christiane Ziegler,et al.  Cantilever-based biosensors , 2004, Analytical and bioanalytical chemistry.

[23]  Jianmin Miao,et al.  Micro-machined piezoelectric membrane-based immunosensor array. , 2008, Biosensors & bioelectronics.

[24]  Ronald G. Polcawich,et al.  AC and DC electrical stress reliability of Piezoelectric Lead Zirconate Titanate (PZT) thin films , 1999 .

[25]  S. Narine,et al.  High-stability quartz-crystal microbalance for investigations in surface science , 2003 .

[26]  Chenming Hu,et al.  Electrical characteristics of ferroelectric PZT thin films for DRAM applications , 1992 .

[27]  Garnett E. Simmers,et al.  Improved Piezoelectric Self-sensing Actuation , 2004 .

[28]  S. Trolier-McKinstry,et al.  Thin Film Piezoelectrics for MEMS , 2004 .

[29]  Robert Puers,et al.  Piezoelectric versus electrostatic actuation for a capacitive RF-MEMS switch , 2002 .

[30]  F. Ayazi,et al.  Thin-film piezoelectric-on-silicon resonators for high-frequency reference oscillator applications , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[31]  M. Miles,et al.  High-Q dynamic force microscopy in liquid and its application to living cells. , 2001, Biophysical journal.

[32]  Srinivas Tadigadapa,et al.  Piezoelectric MEMS sensors: state-of-the-art and perspectives , 2009 .

[33]  C. Steinem,et al.  Piezoelectric Mass-Sensing Devices as Biosensors-An Alternative to Optical Biosensors? , 2000, Angewandte Chemie.

[34]  Reza Abdolvand,et al.  Microelectromechanical disk resonators for direct detection of liquid-phase analytes , 2014 .

[35]  Harri eACT ilmansy Equivalent circuit representation of electromechanical transducers: I. Lumped-parameter systems , 1996 .

[36]  Pedro Martinez Ortiz,et al.  Issues associated with scaling up production of a lab demonstrated MEMS mass sensor , 2012 .

[37]  M. Pandey,et al.  Analysis of Frequency Locking in Optically Driven MEMS Resonators , 2006, Journal of Microelectromechanical Systems.

[38]  Sang Jun Sim,et al.  A multisized piezoelectric microcantilever biosensor array for the quantitative analysis of mass and surface stress , 2008 .

[39]  M. Ferrari,et al.  Improved electronic interfaces for AT-cut quartz crystal microbalance sensors under variable damping and parallel capacitance conditions. , 2008, The Review of scientific instruments.

[40]  Yolanda Jiménez,et al.  Circuit for continuous motional series resonant frequency and motional resistance monitoring of quartz crystal resonators by parallel capacitance compensation , 2002 .

[41]  Alun Harris,et al.  The principle of a MEMS circular diaphragm mass sensor , 2006 .

[42]  Xiaotang Hu,et al.  Piezoelectric microelectromechanical resonant sensors for chemical and biological detection. , 2012, Lab on a chip.

[43]  Zhongyang Cheng,et al.  Piezoelectric biosensor platform based on ZnO micro membrane , 2011 .

[44]  T. Gabrielson Mechanical-thermal noise in micromachined acoustic and vibration sensors , 1993 .