Operation and control of a hybrid wind-diesel-battery energy system connected to micro-grid

This paper presents modeling and control of a hybrid Wind Power, Diesel-Engine Generator (DEG) - Battery energy storage system (BESS) system connected to an electric Micro grid. A case study on the impact of BESS operations on the frequency stability of electric grid has been carried out. The limits on state of charge (SOC) due to limited storage capacity have also been incorporated. The modeling of wind power is also presented and analyzed for a time period of 24-hours with varying wind velocity. Simulation results indicate that BESS system can contribute to frequency stability in both cases when the load increases and also when the load drops. This feature of BESS system will be helpful if it is operated along with a hybrid Wind-PV System.

[1]  Kamil Kaygusuz,et al.  Renewable Energy: Power for a Sustainable Future , 2001 .

[2]  Subhashish Bhattacharya,et al.  Optimal Control of Battery Energy Storage for Wind Farm Dispatching , 2010, IEEE Transactions on Energy Conversion.

[3]  Anjan Bose,et al.  Stability Simulation Of Wind Turbine Systems , 1983, IEEE Transactions on Power Apparatus and Systems.

[4]  Chengxiong Mao,et al.  Use of Battery Energy Storage System to Improve the Power Quality and Stability of Wind Farms , 2006, 2006 International Conference on Power System Technology.

[5]  Debapriya Das,et al.  Battery energy storage for load frequency control of an interconnected power system , 2001 .

[6]  Gilbert M. Masters,et al.  Renewable and Efficient Electric Power Systems: Masters/Electric Power Systems , 2004 .

[7]  O. Wasynczuk,et al.  Dynamic Behavior of a Class of Wind Turbine Generators During Randon Wind Fluctuations , 1981, IEEE Transactions on Power Apparatus and Systems.

[8]  S. Chanana,et al.  Operation and control of a hybrid photovoltaic-diesel-fuel cell system connected to micro-grid , 2012, 2012 IEEE Fifth Power India Conference.

[9]  M. Ceraolo,et al.  New dynamical models of lead-acid batteries , 2000 .

[10]  H. Polinder,et al.  General Model for Representing Variable-Speed Wind Turbines in Power System Dynamics Simulations , 2002, IEEE Power Engineering Review.

[11]  Gilbert M. Masters,et al.  Renewable and Efficient Electric Power Systems , 2004 .

[12]  G. Joos,et al.  The potential of distributed generation to provide ancillary services , 2000, 2000 Power Engineering Society Summer Meeting (Cat. No.00CH37134).

[13]  Ashwani Kumar,et al.  Operation and control of BESS using frequency‐linked pricing in real‐time market with high wind penetration , 2011 .

[14]  Hans B. Puttgen,et al.  Distributed generation: Semantic hype or the dawn of a new era? , 2003 .

[15]  A. Oudalov,et al.  Optimizing a Battery Energy Storage System for Frequency Control Application in an Isolated Power System , 2009, IEEE Transactions on Power Systems.

[16]  C.-C. Liu,et al.  Dynamic modelling of battery energy storage system and application to power system stability , 1995 .