Retrofit of a UK residential property to achieve nearly zero energy building standard

It is currently agreed upon that one of the major challenges in the construction industry is the energy efficiency of existing buildings. The World Meteorological Organisation (WMO) and United Nations (UN) have reported that the concentration of global atmospheric carbon dioxide has increased by an average of 50%, a record speed, from 2015 to 2016. The housing sector contributes to 45% of the UK’s carbon emissions. To help tackle some of those issues the recast Energy Performance Building Directive (EBPD) has introduced Nearly Zero Energy Buildings (NZEBs) in the coming years (including buildings that will undergo refurbishment/ renovations). This paper will explore the retrofitting of a UK residential dwelling using Thermal Analysis Simulation (TAS, EDSL) software by focusing on building fabric improvements and usage of on-site renewables. The CIBSE Test Reference Year (TRY) weather data has been selected to examine the performance of the building under current and future climate projections. The proposed design variables were finally implemented in the building altogether on TAS. The simulation results showed a reduction in the building’s annual energy consumption of 122.64kWh/m2 (90.24%). The greatest savings after this were achieved for the annual reduction in carbon emissions and avoided emissions, which were 84.59% and 816.47kg/CO2, respectively.

[1]  Per Heiselberg,et al.  A Literature Review of Zero Energy Buildings (ZEB) Definitions , 2009 .

[2]  F. Meijer,et al.  Towards a Sustainable Northern European Housing Stock: Figures, Facts and Future , 2009 .

[3]  I. Visa Sustainable Energy in the Built Environment - Steps Towards nZEB , 2014 .

[4]  Shady Attia Zero Energy Retrofit Case Study of a Chalet in Ain-Sukhna, EGYPT , 2010 .

[5]  Alessandra Scognamiglio,et al.  Solution Sets for Net-Zero Energy Buildings: Feedback from 30 Buildings worldwide , 2017 .

[6]  A. Mylona,et al.  Use of Climate Change Scenarios for Building Simulation: the CIBSE Future Weather Years , 2009 .

[7]  lin-shu wang,et al.  Effective heat capacity of interior planar thermal mass (iPTM) subject to periodic heating and cooling , 2012 .

[8]  Eike Musall,et al.  From Low-Energy to Net Zero-Energy Buildings: Status and Perspectives , 2011 .

[9]  Jaume Salom,et al.  Impact of Demand-Side Management on Thermal Comfort and Energy Costs in a Residential nZEB , 2017 .

[10]  Alfonso P. Ramallo-González,et al.  An update of the UK’s test reference year: The implications of a revised climate on building design , 2016 .

[11]  Salvatore Giuffrida,et al.  Energy efficient measure to upgrade a multistory residential in a nZEB , 2017 .

[12]  João Figueiredo,et al.  Energy Production System Management – Renewable energy power supply integration with Building Automation System , 2010 .

[13]  Ali Bahadori-Jahromi,et al.  Impact of standard construction specification on thermal comfort in UK dwellings , 2014 .