High-precision three-dimensional shape reconstruction via digital refocusing in multi-wavelength digital holography.

Three-dimensional (3D) shape reconstructions and metrology measurements are often limited by depth-of-field constraints. Current focus-detection-based techniques are insufficient to profile out-of-focus 3D objects with high axial accuracy. Extended-focus imaging (EFI) techniques can improve the range and precision of such measurements. By incorporating digital refocusing with multiwavelength interferometry, a holographic imaging solution is presented in this paper to accurately measure 3D objects over a large depth range. Accuracy and repeatability of the proposed EFI technique are validated by digital simulations and refocusing experiments. A reconstruction example demonstrates the feasibility of high-precision 3D measurements of objects deeper than the system's classical depth of field.

[1]  Joseph Shamir,et al.  Fourier optics described by operator algebra , 1980 .

[2]  M. K. Kim,et al.  Tomographic three-dimensional imaging of a biological specimen using wavelength-scanning digital interference holography. , 2000, Optics express.

[3]  Bahram Javidi,et al.  Extended focused image in microscopy by digital Holography. , 2005, Optics express.

[4]  F. Dubois,et al.  Improved three-dimensional imaging with a digital holography microscope with a source of partial spatial coherence. , 1999, Applied optics.

[5]  Natan T Shaked,et al.  Simultaneous two-wavelength transmission quantitative phase microscopy with a color camera. , 2010, Optics letters.

[6]  Etienne Cuche,et al.  Real-time dual-wavelength digital holographic microscopy with a single hologram acquisition , 2007 .

[7]  Konstantinos Falaggis,et al.  Multiwavelength interferometry: extended range metrology. , 2009, Optics letters.

[8]  M. K. Kim,et al.  Wavelength-scanning digital interference holography for optical section imaging. , 1999, Optics letters.

[9]  Jun Ni,et al.  Focus detection criterion for refocusing in multi-wavelength digital holography. , 2011, Optics express.

[10]  Hao Qiang Tan Numerical reconstruction of digital hologram , 2011 .

[11]  Robert A. King,et al.  The use of self-entropy as a focus measure in digital holography , 1989, Pattern Recognit. Lett..

[12]  Arnold Nicolaus,et al.  Phase-stepping interferometry: methods for reducing errors caused by camera nonlinearities. , 2002, Applied optics.

[13]  Yeon-Jun Choo,et al.  The characteristics of the particle position along an optical axis in particle holography , 2006 .

[14]  D. J. Brangaccio,et al.  Digital wavefront measuring interferometer for testing optical surfaces and lenses. , 1974, Applied optics.

[15]  T. Bothe,et al.  Spatial phase shifting in electronic speckle pattern interferometry: minimization of phase reconstruction errors. , 1997, Applied optics.

[16]  J. Gass,et al.  Phase imaging without 2pi ambiguity by multiwavelength digital holography. , 2003, Optics letters.

[17]  Carl C. Aleksoff,et al.  Multi-wavelength digital holographic metrology , 2006, SPIE Optics + Photonics.

[18]  P. Carré Installation et utilisation du comparateur photoélectrique et interférentiel du Bureau International des Poids et Mesures , 1966 .

[19]  Toyohiko Yatagai,et al.  Simultaneous depth determination of multiple objects by focus analysis in digital holography , 2008 .

[20]  Giancarlo Pedrini,et al.  Surface contouring in a video frame by changing the wavelength of a diode laser , 1996 .

[21]  Chun-Min Lo,et al.  Phase imaging of cells by simultaneous dual-wavelength reflection digital holography. , 2008, Optics express.

[22]  Etienne Cuche,et al.  Extended depth-of-focus by digital holographic microscopy. , 2010, Optics letters.

[23]  Hao Yu,et al.  Accuracy of a multiple height-transfer interferometric technique for absolute distance metrology , 2011, International Conference on Optical Instruments and Technology.

[24]  Shree K. Nayar,et al.  Shape from Focus , 1994, IEEE Trans. Pattern Anal. Mach. Intell..

[25]  Heinrich Höfler,et al.  Multiwavelength digital holography with autocalibration of phase shifts and artificial wavelengths. , 2009, Applied optics.

[26]  Catherine Yourassowsky,et al.  Focus plane detection criteria in digital holography microscopy by amplitude analysis. , 2006, Optics express.

[27]  Christian Depeursinge,et al.  Submicrometer tomography of cells by multiple-wavelength digital holographic microscopy in reflection. , 2009, Optics letters.

[28]  Etienne Cuche,et al.  Submicrometer optical tomography by multiple-wavelength digital holographic microscopy. , 2006, Applied optics.

[29]  I. Yamaguchi,et al.  Image formation in phase-shifting digital holography and applications to microscopy. , 2001, Applied optics.

[30]  Björn Kemper,et al.  Two-wavelength method for endoscopic shape measurement by spatial phase-shifting speckle-interferometry. , 2004, Applied optics.

[31]  D. Dirksen,et al.  Autofocusing in digital holographic phase contrast microscopy on pure phase objects for live cell imaging. , 2008, Applied optics.

[32]  I. Yamaguchi,et al.  Three-dimensional microscopy with phase-shifting digital holography. , 1998, Optics letters.

[33]  David P Towers,et al.  Generalized frequency selection in multifrequency interferometry. , 2004, Optics letters.