Is magnetic resonance imaging safe for patients with neurostimulation systems used for deep brain stimulation?

n this article, we report to the neurosurgi-cal community important safety concernsrelated to the use of magnetic resonanceimaging (MRI) in patients with neurostimula-tion systems used for deep brain stimulation(DBS). The significance of these concerns isunderscored by our case report in this issueand another published recently (19). Thealarming report of a patient with a DBS im-plant experiencing adverse effects in associa-tion with an MRI examination emphasizes thecrucial importance of strictly following safetyrecommendations. Any attempt to generalizeor trivialize these safety aspects may result inserious temporary or permanent injury to thepatient.The DBS-Magnetic Resonance (DBS-MR)Safety Cooperative Group includes a consor-tium of experts in the fields of MR safety,biomedical engineering, radiology, and neu-rosurgery who have systematically studiedMRI safety for neurostimulation systems forthe past 4 years. In this issue, our group pre-sents a report of a patient who underwentMRI with adverse effects and report the latestfindings with respect to DBS and MRI safety.Of note is that the Food and Drug Adminis-tration recently issued a warning regardingthe use of MRI in patients with neurostimula-tion systems (23).The therapeutic use of electrical stimulationto treat neurological disorders is rapidlygrowing. There are more than 100,000 im-planted neurostimulation devices consistingof DBS, motor cortex stimulation, spinal cordstimulation, vagal nerve stimulation, and pe-ripheral nerve stimulation devices. The num-ber of patients with neurostimulation im-plants is increasing, clinical indications areevolving, and an increasing number of manu-facturers are providing Food and DrugAdministration-approved, or -pending, sys-tems.The focus of this Special Commentary is DBS.With more than 30,000 DBS implants world-wide and Food and Drug Administration-approved indications for treating Parkinson’sdisease, essential tremor, and dystonia, DBS isone of the most rapidly growing areas in thefield of neurosurgery (12, 20, 22). In addition, anumber of clinical trials are underway to assessthe role of DBS in treating epilepsy, chronicpain, cluster headaches, obsessive-compulsivedisorder, major depression, and other relatedconditions.Despite rapid growth in neurostimulationtechnologyandclinicalapplication,therehavebeen few studies directed at assessing thesafety of performing MRI procedures on pa-tients with DBS implants. The neurosurgery,neurology, and radiology communities havenot, for the most part, addressed the safetyfactors of DBS and MRI. The use of MRI pro-cedures for patients with DBS involves vari-ousapproaches. Certaincentersroutinely scanpatients with DBS devices based on thepremise that there have been no problems inthose scanned in the past. In other centers,MRI examinations of patients with DBS im-plants is strictly prohibited, as it is with pa-tients with cardiac pacemakers (1, 14–16).Other centers use various approaches and pol-icies in between.Importantly, the necessity of using MRI ex-aminations in these patients is implicit (3, 4,12, 13). MRI is important for the diagnosis ofhemorrhage, stroke, and other intracranial le-sions; for the assessment of the progression ofneurodegenerative disorders; and for the eval-uation of spinal disorders. In addition, MRI isbeneficial for determining postoperative DBSlead location, crucial for the evaluation of pa-tients with suboptimal results or side effects,

[1]  G. Baltuch,et al.  Electroconvulsive therapy for depression in a Parkinson's disease patient with bilateral subthalamic nucleus deep brain stimulators. , 2005, Parkinsonism & related disorders.

[2]  C. Meyer,et al.  MRT-Untersuchungen des Hirns bei Patienten mit implantierten Herzschrittmachern. Experimentelle und klinische Untersuchungen an einem 1,5 Tesla-System , 2005 .

[3]  Peter Boesiger,et al.  In vivo heating of pacemaker leads during magnetic resonance imaging. , 2005, European heart journal.

[4]  D. Skowasch,et al.  [Magnetic resonance imaging of the brain in patients with cardiac pacemakers. Experimental and clinical investigations at 1.5 Tesla]. , 2005, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[5]  E. Behnke,et al.  Functional neurosurgery in the MRI environment. , 2004, Minimally invasive neurosurgery : MIN.

[6]  F. Shellock,et al.  MR procedures: biologic effects, safety, and patient care. , 2004, Radiology.

[7]  Henry R. Halperin,et al.  Modern Pacemaker and Implantable Cardioverter/Defibrillator Systems Can Be Magnetic Resonance Imaging Safe: In Vitro and In Vivo Assessment of Safety and Function at 1.5 T , 2004, Circulation.

[8]  Jean A. Tkach,et al.  Evaluation of specific absorption rate as a dosimeter of MRI‐related implant heating , 2004, Journal of magnetic resonance imaging : JMRI.

[9]  Jean A. Tkach,et al.  Neurostimulation system used for deep brain stimulation (DBS): MR safety issues and implications of failing to follow safety recommendations. , 2004, Investigative radiology.

[10]  Robert Fair,et al.  Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla. , 2004, Journal of the American College of Cardiology.

[11]  P. Ferroli,et al.  A Simple Method to Assess Accuracy of Deep Brain Stimulation Electrode Placement: Pre-Operative Stereotactic CT + Postoperative MR Image Fusion , 2004, Stereotactic and Functional Neurosurgery.

[12]  V. Tronnier,et al.  Active deep brain stimulation during MRI: A feasibility study , 2004, Magnetic resonance in medicine.

[13]  V. Sturm,et al.  Intraoperative functional MRI as a new approach to monitor deep brain stimulation in Parkinson's disease , 2004, European Radiology.

[14]  Wolfgang Reith,et al.  Transient dystonia following magnetic resonance imaging in a patient with deep brain stimulation electrodes for the treatment of Parkinson disease. Case report. , 2003, Journal of neurosurgery.

[15]  Jorge Gonzalez-Martinez,et al.  MR imaging-related heating of deep brain stimulation electrodes: in vitro study. , 2002, AJNR. American journal of neuroradiology.

[16]  Georg Neubauer,et al.  Temperature measurement on neurological pulse generators during MR scans , 2002, Biomedical engineering online.

[17]  P. Starr,et al.  Implantation of deep brain stimulators into the subthalamic nucleus: technical approach and magnetic resonance imaging-verified lead locations. , 2002, Journal of neurosurgery.

[18]  W. Hamel,et al.  Documentation of electrode localization , 2002, Movement disorders : official journal of the Movement Disorder Society.

[19]  Ashwini Sharan,et al.  Neurostimulation systems for deep brain stimulation: In vitro evaluation of magnetic resonance imaging–related heating at 1.5 tesla , 2002, Journal of magnetic resonance imaging : JMRI.

[20]  Tamer S. Issa,et al.  DBS and diathermy interaction induces severe CNS damage , 2001, Neurology.

[21]  F G Shellock,et al.  MR imaging and electronically activated devices. , 2001, Radiology.

[22]  Y. Katayama,et al.  Thalamotomy Caused by Cardioversion in a Patient Treated with Deep Brain Stimulation , 2001, Stereotactic and Functional Neurosurgery.

[23]  A. Rezai,et al.  Neurostimulation and functional brain imaging , 2000, Neurological research.

[24]  T. W. Athey,et al.  Heating Near Implanted Medical Devices by the MRI RF-magnetic Field , 1999, IEEE International Magnetics Conference.

[25]  C. L. Kwan,et al.  Thalamic stimulation and functional magnetic resonance imaging: localization of cortical and subcortical activation with implanted electrodes. Technical note. , 1999, Journal of neurosurgery.

[26]  V. Tronnier,et al.  Magnetic resonance imaging with implanted neurostimulators: an in vitro and in vivo study. , 1999, Neurosurgery.

[27]  K Bachmann,et al.  Effects of magnetic resonance imaging on cardiac pacemakers and electrodes. , 1997, American heart journal.

[28]  C Marsault,et al.  Chronic thalamic stimulation with three-dimensional MR stereotactic guidance. , 1997, AJNR. American journal of neuroradiology.

[29]  Liong Liem,et al.  Magnetic resonance imaging and spinal cord stimulation systems , 1997, Pain.

[30]  C H Chouard,et al.  [Nuclear magnetic resonance and cochlear implant]. , 1997, Annales d'oto-laryngologie et de chirurgie cervico faciale : bulletin de la Societe d'oto-laryngologie des hopitaux de Paris.

[31]  H. Hricak,et al.  The Effect of Magnetic Resonance Imagers on Implanted Neurostimulators , 1992, Pacing and clinical electrophysiology : PACE.