Bioluminescent bioreporter pad biosensor for monitoring water toxicity.

Toxicants in water sources are of concern. We developed a tool that is affordable and easy-to-use for monitoring toxicity in water. It is a biosensor composed of disposable bioreporter pads (calcium alginate matrix with immobilized bacteria) and a non-disposable CMOS photodetector. Various parameters to enhance the sensor's signal have been tested, including the effect of alginate and bacterium concentrations. The effect of various toxicants, as well as, environmental samples were tested by evaluating their effect on bacterial luminescence. This is the first step in the creation of a sensitive and simple operative tool that may be used in different environments.

[1]  M. Pardos,et al.  Confirmation of elemental sulfur toxicity in the Microtox® assay during organic extracts assessment of freshwater sediments , 1999 .

[2]  Thomas Haneder,et al.  CMOS-based biosensor arrays , 2005, Design, Automation and Test in Europe.

[3]  A. Tatar,et al.  The effects of some boron compounds against heavy metal toxicity in human blood. , 2012, Experimental and toxicologic pathology : official journal of the Gesellschaft fur Toxikologische Pathologie.

[4]  Ahmad Umar,et al.  Ultra-high sensitive ammonia chemical sensor based on ZnO nanopencils. , 2012, Talanta.

[5]  Nicole Jaffrezic-Renault,et al.  Conductometric formaldehyde sensitive biosensor with specifically adapted analytical characteristics , 2001 .

[6]  J. Marsel,et al.  Gas chromatographic determination of formaldehyde in air using solid-phase microextraction sampling , 1998 .

[7]  A. Axelsson,et al.  Diffusion in gels containing immobilized cells: A critical review , 1991, Biotechnology and bioengineering.

[8]  D. Bagchi,et al.  Cytotoxicity and oxidative mechanisms of different forms of chromium. , 2002, Toxicology.

[9]  J. Švitel,et al.  Immobilization in biotechnology and biorecognition: from macro- to nanoscale systems , 2012, Chemical Papers.

[10]  C. Lacroix,et al.  Diffusion of lactose in k‐carrageenan/locust bean gum gel beads with or without entrapped growing lactic acid bacteria , 1991 .

[11]  Luoping Zhang,et al.  Formaldehyde and Leukemia: An Updated Meta-Analysis and Evaluation of Bias , 2010, Journal of occupational and environmental medicine.

[12]  L. E. Diaz,et al.  Development of sol-gel hybrid materials for whole cell immobilization. , 2009, Recent patents on biotechnology.

[13]  R. Schwarzenbach,et al.  The Challenge of Micropollutants in Aquatic Systems , 2006, Science.

[14]  L. Lawton,et al.  Extraction and high-performance liquid chromatographic method for the determination of microcystins in raw and treated waters. , 1994, The Analyst.

[15]  A. Axelsson,et al.  Determination of effective diffusion coefficients in calcium alginate gel plates with varying yeast cell content , 1988 .

[16]  P. Jorge Fiber optic refractometric configurations for environmental sensing , 2010 .

[17]  Robert S. Marks,et al.  Bioluminescent liquid light guide pad biosensor for indoor air toxicity monitoring. , 2015, Analytical chemistry.

[18]  C. Vílchez,et al.  Diffusion characteristics of nitrate and glycerol in alginate , 2002 .

[19]  T. Giarrizzo,et al.  Fish and aquatic habitat conservation in South America: a continental overview with emphasis on neotropical systems. , 2010, Journal of fish biology.

[20]  Raghubir P. Sharma,et al.  Vanadium accumulation and subcellular distribution in relation to vanadate induced cytotoxicity in vitro , 1985, Cell Biology and Toxicology.

[21]  Sandeep Kumar Jha,et al.  Optical microbial biosensor for detection of methyl parathion pesticide using Flavobacterium sp. whole cells adsorbed on glass fiber filters as disposable biocomponent. , 2006, Biosensors & bioelectronics.

[22]  Recep Avci,et al.  Efficient immobilization and patterning of live bacterial cells. , 2008, Langmuir : the ACS journal of surfaces and colloids.

[23]  Z. Aksu,et al.  A comparative study of copper(II) biosorption on Ca-alginate, agarose and immobilized C. vulgaris in a packed-bed column , 1998 .

[24]  David C Cullen,et al.  Monitoring and classification of PAH toxicity using an immobilized bioluminescent bacteria. , 2003, Biosensors & bioelectronics.

[25]  Michael Thompson,et al.  Inductively coupled plasma mass spectrometry , 1988 .

[26]  J. Budna,et al.  Silane-modified surfaces in specific antibody-mediated cell recognition. , 2014, Folia histochemica et cytobiologica.

[27]  Wilfred Chen,et al.  Whole‐Cell Immobilization Using Cell Surface‐Exposed Cellulose‐Binding Domain , 2001, Biotechnology progress.

[28]  R. Marks,et al.  Detection of sub-inhibitory antibiotic concentrations via luminescent sensing bacteria and prediction of their mode of action , 2008 .

[29]  R. Bos,et al.  Sick water?. The central role of wastewater management in sustainable development. A rapid response assessment , 2010 .

[30]  R. Marks,et al.  Creation of a new portable biosensor for water toxicity determination , 2015 .

[31]  U. R. Acharya,et al.  Lead acetate induced cytotoxicity in male germinal cells of Swiss mice. , 2003, Industrial health.

[32]  M. A. Marin-Morales,et al.  Genotoxicity and mutagenicity of water contaminated with tannery effluents, as evaluated by the micronucleus test and comet assay using the fish Oreochromis niloticus and chromosome aberrations in onion root-tips , 2006 .

[33]  M. Kosseva,et al.  Immobilization of Microbial Cells in Food Fermentation Processes , 2011 .

[34]  G. Sayler,et al.  Optical biosensor for environmental on-line monitoring of naphthalene and salicylate bioavailability with an immobilized bioluminescent catabolic reporter bacterium , 1994, Applied and environmental microbiology.

[35]  Zhaoyong Zhang,et al.  Determination of Occurrence Characteristics of Heavy Metals in Soil and Water Environments in Tianshan Mountains, Central Asia , 2013 .

[36]  Xiaowei Zhang,et al.  Risk and toxicity assessments of heavy metals in sediments and fishes from the Yangtze River and Taihu Lake, China. , 2013, Chemosphere.

[37]  Yook Heng Lee,et al.  Microencapsulated Aliivibrio fischeri in Alginate Microspheres for Monitoring Heavy Metal Toxicity in Environmental Waters , 2014, Sensors.

[38]  L. Wiesmüller,et al.  Proof of principle: detection of genotoxicity by a fluorescence-based recombination test in mammalian cells. , 2003, ALTEX.

[39]  B. Volesky,et al.  Biosorption: a solution to pollution? , 2000, International microbiology : the official journal of the Spanish Society for Microbiology.

[40]  P.-A. Besse,et al.  Single photon detector fabricated in a complementary metal-oxide-semiconductor high-voltage technology , 2003 .

[41]  Boris Polyak,et al.  Synthesis and characterization of a biotin-alginate conjugate and its application in a biosensor construction. , 2004, Biomacromolecules.

[42]  R. Burbano,et al.  Cytotoxicity and genotoxicity of low doses of mercury chloride and methylmercury chloride on human lymphocytes in vitro. , 2005, Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas.

[43]  Serge Cosnier,et al.  Synthesis and characterization of a pyrrole-alginate conjugate and its application in a biosensor construction. , 2004, Biomacromolecules.

[44]  Jan Roelof van der Meer,et al.  Measurement of Biologically Available Naphthalene in Gas and Aqueous Phases by Use of a Pseudomonas putida Biosensor , 2004, Applied and Environmental Microbiology.

[45]  K. Wilkinson,et al.  Diffusion of ions in a calcium alginate hydrogel-structure is the primary factor controlling diffusion. , 2013, Carbohydrate polymers.

[46]  Stefano Girotti,et al.  Monitoring of environmental pollutants by bioluminescent bacteria. , 2008, Analytica chimica acta.

[47]  L. Güiza,et al.  Mercury and gold mining in Colombia : a failed state , 2013 .

[48]  Zhenghua Song,et al.  On-Line Monitoring of Formaldehyde In Water and Air Using Chemiluminescence Detection , 2003 .

[49]  M. A. Marin-Morales,et al.  Mutagenic potential evaluation of the water of a river that receives tannery effluent using the Allium cepa test system , 2004 .

[50]  Richard A. Durst,et al.  ELECTROCHEMICAL BIOSENSORS: RECOMMENDED DEFINITIONS AND CLASSIFICATION* , 2001 .

[51]  H. Shiraishi,et al.  Luminescent yeast cells entrapped in hydrogels for estrogenic endocrine disrupting chemical biodetection. , 2006, Biosensors & bioelectronics.

[52]  On-line biosensor for the detection of putative toxicity in water contaminants. , 2015, Talanta.

[53]  M. Sabater-Vilar,et al.  Mutagenicity of mercury chloride and mechanisms of cellular defence: the role of metal-binding proteins. , 2000, Mutagenesis.

[54]  Shimshon Belkin,et al.  Bioluminescent whole cell optical fiber sensor to genotoxicants: system optimization , 2001 .

[55]  Zongwei Ma,et al.  Ecological risk assessment of heavy metals in surface sediments of six major chinese freshwater lakes. , 2013, Journal of environmental quality.

[56]  L. Kochian,et al.  Aluminum interaction with plasma membrane lipids and enzyme metal binding sites and its potential role in Al cytotoxicity , 1997, FEBS letters.

[57]  P. Riley,et al.  Cytotoxicity of zinc in vitro. , 1989, Chemico-biological interactions.

[58]  Shimshon Belkin,et al.  Optical fiber bioluminescent whole-cell microbial biosensors to genotoxicants , 2000 .

[59]  Marko Virta,et al.  Detection of bioavailable heavy metals in EILATox‐Oregon samples using whole‐cell luminescent bacterial sensors in suspension or immobilized onto fibre‐optic tips , 2004, Journal of applied toxicology : JAT.

[60]  T. Heo,et al.  Survival of Bifidobacterium longumImmobilized in Calcium Alginate Beads in Simulated Gastric Juices and Bile Salt Solution , 2000, Applied and Environmental Microbiology.

[61]  J. Fritz,et al.  A rapid, simple method for determining formaldehyde in drinking water using colorimetric-solid phase extraction. , 2009, Talanta.