Control of DFIG for rotor current harmonics elimination

Unbalanced stator conditions cause rotor current harmonics and torque pulsations in Doubly-Fed Induction Generators (DFIG) which are used widely in wind energy systems. From a hardware perspective, current control techniques to minimize the rotor current harmonics include rotor-side converter injected voltage compensation and grid-side converter compensation. From a software perspective, the current controllers either adopt synchronous reference frame for controller design or adopt positive synchronous (qd+) negative synchronous reference frames (qd−) to decompose the harmonics in rotor currents and control them separately. This paper develops a proportional resonance (PR) control strategy in the stationary reference frame (αβ) to minimize rotor current harmonics and torque pulsations. The main advantages of the proposed method are (i) only one transformation (abc/αβ) is required and (ii) harmonic filters are not required. The proposed control strategy is compared with the proportional integral (PI) control strategyin qd+ and qd− and the proportional integral and resonant (PIR) control strategy in qd+. Simulations performed in Matlab/Simulink are presented to illustrate the effectiveness of the proposed control strategy.

[1]  A. G. A.O. Fitzgerald Electric machinery : the processes, devices and systems of electromechanical energy conversion / A.E. Fitzgerald, Charles Kingley, Irand Alexander Kusco , 1971 .

[2]  Jiabing Hu,et al.  Modeling and Control of Grid-Connected Voltage-Sourced Converters Under Generalized Unbalanced Operation Conditions , 2008, IEEE Transactions on Energy Conversion.

[3]  N. Mohan,et al.  Control of a Doubly Fed Induction Wind Generator Under Unbalanced Grid Voltage Conditions , 2007, IEEE Transactions on Energy Conversion.

[4]  J. Clare,et al.  Control System for Unbalanced Operation of Stand-Alone Doubly Fed Induction Generators , 2007, IEEE Transactions on Energy Conversion.

[5]  Jiabing Hu,et al.  Modeling and enhanced control of DFIG under unbalanced grid voltage conditions , 2009 .

[6]  Frede Blaabjerg,et al.  Proportional-resonant controllers and filters for grid-connected voltage-source converters , 2006 .

[7]  Lingling Fan,et al.  The art of modeling and simulation of induction generator in wind generation applications using high-order model , 2008, Simul. Model. Pract. Theory.

[8]  R. W. De Doncker,et al.  Doubly fed induction generator systems for wind turbines , 2002 .

[9]  Lie Xu,et al.  Dynamic Modeling and Control of DFIG-Based Wind Turbines Under Unbalanced Network Conditions , 2007, IEEE Transactions on Power Systems.

[10]  Frede Blaabjerg,et al.  Proportionalresonant controllers and filters for gridconnected voltagesource converters , 2006 .

[11]  Ned Mohan First Course on Power Electronics and Drives , 1989 .