Investigation of the Rotor Demagnetization Characteristics of Interior PM Synchronous Machines During Fault Conditions

This paper investigates the transient magnetic behavior of an interior permanent-magnet (IPM) synchronous machine following a large transient current caused by a fault condition. A combination of finite-element (FE) analysis and numerical integration of the machine equations is used to calculate the currents resulting from a symmetrical three-phase short-circuit fault at the machine terminals, including magnetic saturation effects. FE analysis is further used to simulate the magnetic behavior of the machine when subjected to the fault currents, with a particular focus on the propagation of the demagnetizing MMF throughout the conductive laminations as well as the conductive PM material. Eddy currents induced in the laminations and magnet material are shown to impede the progression of the demagnetizing MMF. However, the transient analysis illustrates the manner in which the fault currents ultimately trigger the onset of irreversible demagnetization of significant portions of the rotor magnets in the analyzed machine. The transient demagnetization analysis method is extended to investigate the influence of several key design variables, including machine operating temperature and segmentation of the rotor magnets.

[1]  J. Hur,et al.  Analysis of irreversible magnet demagnetization in line-start motors based on the finite-element method , 2003 .

[2]  Gyu-Hong Kang,et al.  Optimal design of spoke type BLDC motor considering irreversible demagnetization of permanent magnet , 2003, Sixth International Conference on Electrical Machines and Systems, 2003. ICEMS 2003..

[3]  A. Arkkio,et al.  Interdependence of Demagnetization, Loading, and Temperature Rise in a Permanent-Magnet Synchronous Motor , 2010, IEEE Transactions on Magnetics.

[4]  Massimo Barcaro,et al.  Faulty Operations of a PM Fractional-Slot Machine With a Dual Three-Phase Winding , 2011, IEEE Transactions on Industrial Electronics.

[5]  Gyu-Hong Kang,et al.  Characteristic analysis of IPM type BLDC motor considering the demagnetization of PM by stator turn fault , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[6]  Barrie Mecrow,et al.  Fault-tolerant permanent magnet machine drives , 1995 .

[7]  D. Stone,et al.  Rotor loss in permanent-magnet brushless AC machines , 2000 .

[8]  Antero Arkkio,et al.  Demagnetisation state of permanent magnets in large output power permanent magnet synchronous motor , 1999, IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272).

[9]  J. Kolehmainen,et al.  Demagnetization Testing for a Mixed-Grade Dovetail Permanent-Magnet Machine , 2009, IEEE Transactions on Magnetics.

[10]  H. Karmaker,et al.  Short-Circuit Analysis of Permanent-Magnet Generators , 2009, IEEE Transactions on Industry Applications.

[11]  G. Pellegrino,et al.  Magnet minimization in IPM-PMASR motor design for wide speed range application , 2011, 2011 IEEE Energy Conversion Congress and Exposition.

[12]  T. M. Jahns,et al.  Design, analysis and loss minimization of a fractional-slot concentrated winding IPM machine for traction applications , 2011, 2011 IEEE Energy Conversion Congress and Exposition.