Theoretical analysis of protein concentration determination using biosensor technology under conditions of partial mass transport limitation.

The theory of a method for determining active concentration of nonpurified protein samples using the BIAcore biosensor technology has been developed. The method relies on change in binding rate with varying flow rate at high ligand concentration where mass transport from bulk to surface with immobilized ligand becomes partially rate limiting. Prior study of binding kinetics is not necessary. If the molecular weight and the diffusion coefficient of the analyte protein are known, no standard with a known concentration is required. From numeric computer simulations a simple analytical expression for the mass transport coefficient derived at totally mass transport limiting conditions is shown to be applicable for conditions of partial mass transport limitation. Simple one to one association is assumed in deriving the method, but it is applicable even with more complex kinetics due to a bivalent analyte or heterogeneity of analyte or ligand.

[1]  M L Yarmush,et al.  An analysis of transport resistances in the operation of BIAcore; implications for kinetic studies of biospecific interactions. , 1996, Molecular immunology.

[2]  A. Minton,et al.  Analysis of mass transport-limited binding kinetics in evanescent wave biosensors. , 1996, Analytical biochemistry.

[3]  P. Schuck,et al.  Kinetics of ligand binding to receptor immobilized in a polymer matrix, as detected with an evanescent wave biosensor. I. A computer simulation of the influence of mass transport. , 1996, Biophysical journal.

[4]  R. Karlsson,et al.  Analysis of active antibody concentration. Separation of affinity and concentration parameters. , 1993, Journal of immunological methods.

[5]  R. Karlsson,et al.  Biospecific interaction analysis using surface plasmon resonance detection applied to kinetic, binding site and concentration analysis. , 1992, Journal of chromatography.

[6]  C. Urbaniczky,et al.  Integrated fluid handling system for biomolecular interaction analysis. , 1991, Analytical chemistry.

[7]  J. J. Anderson,et al.  Numerical simulation of convective diffusion at a rectangular channel flow electrode , 1984 .

[8]  J. L. Anderson,et al.  Amperometric response of a rectangular channel electrode , 1984 .

[9]  D. M. Morgan,et al.  Theoretical and practical limitations on the optimization of amperometric detectors. , 1984, Analytical chemistry.

[10]  B. K. Lok,et al.  Protein adsorption on crosslinked polydimethylsiloxane using total internal reflection fluorescence , 1983 .

[11]  P. G. de Gennes,et al.  Conformations of Polymers Attached to an Interface , 1980 .

[12]  M. Himmel,et al.  Hydrodynamics and protein hydration. , 1979, Archives of biochemistry and biophysics.

[13]  W. C. Purdy,et al.  The behaviour of an electrochemical detector used in liquid chromatography and continuous flow voltammetry: Part 2. Evaluation of low-temperature isotropic carbon for use as an electrode material , 1978 .

[14]  S. H. Armstrong,et al.  Preparation and properties of serum and plasma proteins; the refractive properties of the proteins of human plasma and certain purified fractions. , 1947, Journal of the American Chemical Society.