Implementation of body area networks based on MICS/WMTS medical bands for healthcare systems

A multi-hoping sensor network system has been implemented to monitor physiological parameters from multiple patient bodies by means of medical communication standards MICS (Medical Implant Communication Service) and WMTS (Wireless Medical Telemetry Service). Unlike the other medical sensor networks (they usually use 2.4 GHz ISM band), we used the two medical standards occupying the frequency bands that are mainly assigned to medical applications. The prototype system uses the MICS band (402–405 MHz) between the sensor nodes and a remote central control unit (CCU). And WMTS frequencies (608–614MHz) are used between the CCUs and the remote base stations allowing for a much larger range acting as an intermediate node. The sensor nodes in the prototype can measure up to four body signals (i.e. 4-channel) where one is dedicated to a continuous physiological signal such as ECC/EEG. The system includes firmware and software designs that can provide a long distance data transfer through the internet or a mobile network.

[1]  Wook Hyun Kwon,et al.  Mutual interference analysis of IEEE 802.15.4 and IEEE 802.11b , 2007, Comput. Networks.

[2]  C.H. Chan,et al.  A Hybrid Body Sensor Network for Continuous and Long-term Measurement of Arterial Blood Pressure , 2007, 2007 4th IEEE/EMBS International Summer School and Symposium on Medical Devices and Biosensors.

[3]  Huan-Bang Li,et al.  Introduction of SG-BAN in IEEE 802.15 With Related Discussion , 2007, 2007 IEEE International Conference on Ultra-Wideband.

[4]  William G. Scanlon,et al.  Analysis of the performance of IEEE 802.15.4 for medical sensor body area networking , 2004, 2004 First Annual IEEE Communications Society Conference on Sensor and Ad Hoc Communications and Networks, 2004. IEEE SECON 2004..

[5]  Wentai Liu,et al.  A Wireless Medical Monitoring Over a Heterogeneous Sensor Network , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[6]  Paul Lukowicz,et al.  AMON: a wearable multiparameter medical monitoring and alert system , 2004, IEEE Transactions on Information Technology in Biomedicine.

[7]  Jong Min Choi,et al.  Hardware design & compression issues in compact Bluetooth enabled wireless telecardiology system , 2005, 2nd International Conference on Broadband Networks, 2005..

[8]  M. Welsh,et al.  Vital Signs Monitoring and Patient Tracking Over a Wireless Network , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[9]  A. Sikora,et al.  Coexistence of IEEE802.15.4 with other Systems in the 2.4 GHz-ISM-Band , 2005, 2005 IEEE Instrumentationand Measurement Technology Conference Proceedings.

[10]  Nada Golmie,et al.  Performance analysis of low rate wireless technologies for medical applications , 2005, Comput. Commun..

[11]  Mohd Fadlee A. Rasid,et al.  Bluetooth telemedicine Processor for multichannel biomedical signal transmission via mobile cellular networks , 2005, IEEE Transactions on Information Technology in Biomedicine.

[12]  Ivan Howitt,et al.  IEEE 802.15.4 low rate - wireless personal area network coexistence issues , 2003, 2003 IEEE Wireless Communications and Networking, 2003. WCNC 2003..

[13]  E. Jovanov,et al.  A WBAN-based System for Health Monitoring at Home , 2006, 2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors.