A fast and robust reference current generation algorithm for three-phase shunt active power filter

The identification of the reference currents constitutes an important part of the control of the active power filter. This part requires an accurate estimation of the frequency, phase, and proper extraction of the load current harmonics. This makes the modeling more difficult and requests a rigorous selection of techniques to be used. For the sake of simplicity, the direct method is motivated by the need for the simplicity and flexibility than the existing techniques such as the instantaneous power theory and diphase currents method. However, this method requires a robust phase-locked loop to extract the unity voltages and a robust controller to estimate the magnitude of the source current. To this end, this paper proposes the hybrid phase-locked loop (HPLL) as a good option mainly because 1) it achieves zero phase error under frequency drifts, 2) Fast dynamic response, 3) totally block the DC offset, 4) From the control point of view, it is a type 1 control system which results in high stability margin. To the best of authors’ knowledge, the HPLL has not been used in active power filter yet. Furthermore, a neural PI regulator is used to estimate the magnitude of the source current. Simulation results show the efficiency of the proposed technique and illustrate all its interesting features. For the sake of comparison, the proposed method is compared to other advanced techniques.

[1]  Josep M. Guerrero,et al.  Hybrid Synchronous/Stationary Reference-Frame-Filtering-Based PLL , 2015, IEEE Transactions on Industrial Electronics.

[2]  Dedet Candra Riawan,et al.  Control Design For Shunt Active Power Filter Based On p-q Theory In Photovoltaic Grid-Connected System , 2018 .

[3]  Ahmed Safa,et al.  Real Time Control of an Active Power Filter under Distorted Voltage Condition , 2012 .

[4]  El Madjid Berkouk,et al.  An improved sliding mode controller for a multifunctional photovoltaic grid tied inverter , 2017 .

[5]  Zubair Ahmed Memon,et al.  Power Quality Improvement in QUCEST Larkana Campus by Using Three Types of Power Filters , 2017 .

[6]  P. Thirumoorthi,et al.  Adaptive Method for Power Quality Improvement through Minimization of Harmonics Using Artificial Intelligence , 2017 .

[7]  Dalila Mat Said,et al.  Low-voltage ride-through for a three-phase four-leg photovoltaic system using SRFPI control strategy , 2019 .

[8]  Messlem Youcef,et al.  Sensorless Sliding Mode Vector Control of Induction Motor Drives , 2012 .

[9]  R. Chudamani,et al.  Real-Time Estimation of Power System Frequency Using Nonlinear Least Squares , 2009, IEEE Transactions on Power Delivery.

[10]  Dalila Mat Said,et al.  Low-voltage Ride-through Methods for Grid-connected Photovoltaic Systems in Microgrids: A Review and Future Prospect , 2018 .

[11]  S. P. Dubey,et al.  ANN based Hybrid Active Power Filter for Harmonics Elimination with Distorted Mains , 2012 .

[12]  Youcef Messlem,et al.  ADALINE-Based Speed Control For Induction Motor Drive , 2019, 2019 International Conference on Advanced Electrical Engineering (ICAEE).

[13]  Ahmed Safa,et al.  Expiremental validation of a fault tolerant control of induction motor using a voting algorithm , 2015, 2015 3rd International Conference on Control, Engineering & Information Technology (CEIT).

[14]  Patrice Wira,et al.  A Unified Artificial Neural Network Architecture for Active Power Filters , 2007, IEEE Transactions on Industrial Electronics.

[15]  Frede Blaabjerg,et al.  Harmonic Stability in Power Electronic-Based Power Systems: Concept, Modeling, and Analysis , 2019, IEEE Transactions on Smart Grid.

[16]  D. Boroyevich,et al.  Decoupled Double Synchronous Reference Frame PLL for Power Converters Control , 2007, IEEE Transactions on Power Electronics.

[17]  Ghlib Imane,et al.  Neural Adaptive Kalman Filter for Sensorless Vector Control of Induction Motor , 2017 .

[18]  Vinod Khadkikar,et al.  Artificial-Neural-Network-Based Phase-Locking Scheme for Active Power Filters , 2014, IEEE Transactions on Industrial Electronics.

[19]  Juan C. Vasquez,et al.  Three-Phase PLLs: A Review of Recent Advances , 2017, IEEE Transactions on Power Electronics.

[20]  Nour-Eddine Tariba,et al.  A new SOGI-PLL method based on fuzzy logic for grid connected PV inverter , 2019 .

[21]  Juan C. Vasquez,et al.  Performance improvement of shunt active power filter based on non-linear least-square approach , 2018, Electric Power Systems Research.

[22]  Malabika Basu,et al.  Real-time control of shunt active power filter under distorted grid voltage and unbalanced load condition using self-tuning filter , 2014 .

[23]  Javier Morales,et al.  Model-Based Control for a Three-Phase Shunt Active Power Filter , 2016, IEEE Transactions on Industrial Electronics.

[24]  El Madjid Berkouk,et al.  A robust control algorithm for a multifunctional grid tied inverter to enhance the power quality of a microgrid under unbalanced conditions , 2018, International Journal of Electrical Power & Energy Systems.

[25]  Mohamed Tadjine,et al.  Global fault‐tolerant control approach for vector control of an induction motor , 2020 .

[26]  Tole Sutikno,et al.  Comparisons of PI and ANN controllers for shunt HPF based on STF-PQ Algorithm under distorted grid voltage , 2019 .

[27]  Bimal K. Bose,et al.  Global Energy Scenario and Impact of Power Electronics in 21st Century , 2013, IEEE Transactions on Industrial Electronics.

[28]  Mark Sumner,et al.  Real-Time Estimation of Fundamental Frequency and Harmonics for Active Shunt Power Filters in Aircraft Electrical Systems , 2009, IEEE Transactions on Industrial Electronics.

[29]  Josep M. Guerrero,et al.  Performance Improvement of a Prefiltered Synchronous-Reference-Frame PLL by Using a PID-Type Loop Filter , 2014, IEEE Transactions on Industrial Electronics.

[30]  Patrice Wira,et al.  A novel robust PLL algorithm applied to the control of a shunt active power filter using a self tuning filter concept , 2018, 2018 IEEE International Conference on Industrial Technology (ICIT).