Finite element analysis of the amputated lower limb: A systematic review and recommendations.

The care and rehabilitation of individuals after lower limb amputation presents a substantial and growing socioeconomic challenge. Clinical outcome is closely linked to successful functional rehabilitation with a prosthetic limb, which depends upon comfortable prosthetic limb - residual limb load transfer. Despite early interest in the 1980s, the amputated limb has received considerably less attention in computational biomechanical analysis than other subjects, such as arthroplasty. This systematic literature review investigates the state of the art in residual limb finite element analysis published since 2000. The identified studies were grouped into the following categories: (1) residuum-prosthesis interface mechanics; (2) residuum soft tissue internal mechanics; (3) identification of residuum tissue characteristics; (4) proposals for incorporating FEA into the prosthesis fitting process; (5) analysis of the influence of prosthetic componentry concepts to improve load transfer to the residuum, such as the monolimb and structural socket compliance; and (6) analysis of osseointegrated (OI) prostheses. The state of the art is critically appraised in order to form recommendations for future modeling studies in terms of geometry, material properties, boundary conditions, interface models, and relevant but un-investigated issues. Finally, the practical implementation of these approaches is discussed.

[1]  D. Wipke-Tevis,et al.  Elevated sacral skin temperature (T(s)): a risk factor for pressure ulcer development in hospitalized neurologically impaired Thai patients. , 2005, Applied nursing research : ANR.

[2]  Anne Simmons,et al.  Concurrent multibody and Finite Element analysis of the lower-limb during amputee running , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[3]  Frans C T van der Helm,et al.  Comparison of measurements of medial gastrocnemius architectural parameters from ultrasound and diffusion tensor images. , 2015, Journal of biomechanics.

[4]  K. Hagberg,et al.  Osseointegrated trans-femoral amputation prostheses: Prospective results of general and condition-specific quality of life in 18 patients at 2-year follow-up , 2008, Prosthetics and orthotics international.

[5]  A. Crocombe,et al.  Finite element analysis of bone stress and strain around a distal osseointegrated implant for prosthetic limb attachment , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[6]  J. Jensen,et al.  Operative technique in knee disarticulation , 1983, Prosthetics and orthotics international.

[7]  H. E. Loon Below-Knee Amputation Surgery , 2007 .

[8]  A. Gefen,et al.  Pressure-time cell death threshold for albino rat skeletal muscles as related to pressure sore biomechanics. , 2006, Journal of biomechanics.

[9]  K. Hagberg,et al.  Osseointegrated Titanium Implants for Limb Prostheses Attachments: Infectious Complications , 2010, Clinical orthopaedics and related research.

[10]  A. Gefen,et al.  Mechanics of the normal woman's breast. , 2007, Technology and health care : official journal of the European Society for Engineering and Medicine.

[11]  Xiaohong Jia,et al.  Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket. , 2004, Medical engineering & physics.

[12]  N Verdonschot,et al.  Numerical analysis of an osseointegrated prosthesis fixation with reduced bone failure risk and periprosthetic bone loss. , 2012, Journal of biomechanics.

[13]  P. Fromme,et al.  Effect of amputation level on the stress transferred to the femur by an artificial limb directly attached to the bone. , 2013, Medical engineering & physics.

[14]  A. Mak,et al.  Regional differences in pain threshold and tolerance of the transtibial residual limb: including the effects of age and interface material. , 2005, Archives of physical medicine and rehabilitation.

[15]  D L Bader,et al.  Development and validation of a 3D-printed interfacial stress sensor for prosthetic applications. , 2015, Medical engineering & physics.

[16]  Frank Seehaus,et al.  Multi‐body simulation of various falling scenarios for determining resulting loads at the prosthesis interface of transfemoral amputees with osseointegrated fixation , 2013, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[17]  Clayton J Adam,et al.  FE stress analysis of the interface between the bone and an osseointegrated implant for amputees--implications to refine the rehabilitation program. , 2008, Clinical biomechanics.

[18]  Krouskop Ta,et al.  Computer-aided design of a prosthetic socket for an above-knee amputee. , 1987 .

[19]  Kenneth Hoyt,et al.  Quantitative sonoelastography for the in vivo assessment of skeletal muscle viscoelasticity , 2008, Physics in medicine and biology.

[20]  S G Zachariah,et al.  Material properties of commonly-used interface materials and their static coefficients of friction with skin and socks. , 1998, Journal of rehabilitation research and development.

[21]  E. Zimerson,et al.  Skin disorders in amputees. , 2000, Journal of the American Academy of Dermatology.

[22]  Wei Xu,et al.  X-Ray Image Review of the Bone Remodeling Around an Osseointegrated Trans-femoral Implant and a Finite Element Simulation Case Study , 2008, Annals of Biomedical Engineering.

[23]  Caterina Rizzi,et al.  A new design paradigm for the development of custom-fit soft sockets for lower limb prostheses , 2010, Comput. Ind..

[24]  Y. Kakitsubata,et al.  Skeletal muscle disease: patterns of MRI appearances. , 2012, The British journal of radiology.

[25]  Oliver T Mytton,et al.  Introducing new technology safely , 2010, Quality and Safety in Health Care.

[26]  M. Mooney A Theory of Large Elastic Deformation , 1940 .

[27]  W. Xu,et al.  Three-Dimensional Finite Element Stress and Strain Analysis of a Transfemoral Osseointegration Implant , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[28]  M. J. Gómez-Benito,et al.  Challenges in the Modeling of Wound Healing Mechanisms in Soft Biological Tissues , 2014, Annals of Biomedical Engineering.

[29]  Laurent Frossard,et al.  Load applied on bone-anchored transfemoral prosthesis: characterization of a prosthesis-a pilot study. , 2013, Journal of rehabilitation research and development.

[30]  Dr D. P. Reynolds,et al.  Interface load analysis for computer-aided design of below-knee prosthetic sockets , 1992, Medical and Biological Engineering and Computing.

[31]  Chih-Han Chang,et al.  Effects of liner stiffness for trans-tibial prosthesis: a finite element contact model. , 2004, Medical engineering & physics.

[32]  A. Gefen,et al.  Internal mechanical conditions in the soft tissues of a residual limb of a trans-tibial amputee. , 2008, Journal of biomechanics.

[33]  C. Scoville,et al.  Amputation Is Not Isolated: An Overview of the US Army Amputee Patient Care Program and Associated Amputee Injuries , 2006, The Journal of the American Academy of Orthopaedic Surgeons.

[34]  J. Geertzen,et al.  A patient with donning-related stump wounds: A case report , 2008, Prosthetics and orthotics international.

[35]  Y. Istefanopulos,et al.  IEEE Engineering in Medicine and Biology Society , 2019, IEEE Transactions on Biomedical Engineering.

[36]  Frank Seehaus,et al.  Loads on the prosthesis-socket interface of above-knee amputees during normal gait: validation of a multi-body simulation. , 2013, Journal of biomechanics.

[37]  David Backman,et al.  Evaluating the bending response of two osseointegrated transfemoral implant systems using 3D digital image correlation. , 2011, Journal of biomechanical engineering.

[38]  J. Sullivan,et al.  Rehabilitation of the transfemoral amputee with an osseointegrated prosthesis: The United Kingdom experience , 2003, Prosthetics and orthotics international.

[39]  Joan E Sanders,et al.  Shape and volume change in the transtibial residuum over the short term: preliminary investigation of six subjects. , 2004, Journal of rehabilitation research and development.

[40]  Hugh Herr,et al.  Multi-material 3-D viscoelastic model of a transtibial residuum from in-vivo indentation and MRI data. , 2016, Journal of the mechanical behavior of biomedical materials.

[41]  T. Kuiken,et al.  A computational model for stress reduction at the skin-implant interface of osseointegrated prostheses. , 2012, Journal of biomedical materials research. Part A.

[42]  Braden C Fleming,et al.  Accuracy of circular contact area measurements with thin-film pressure sensors. , 2007, Journal of biomechanics.

[43]  J. Ossa,et al.  RELATION BETWEEN RESIDUAL LIMB LENGTH AND STRESS DISTRIBUTION OVER STUMP FOR TRANSFEMORAL AMPUTEES , 2015 .

[44]  J C H Goh,et al.  Development of an integrated CAD-FEA process for below-knee prosthetic sockets. , 2005, Clinical biomechanics.

[45]  Lisette Schoonhoven,et al.  The physiological response of soft tissue to periodic repositioning as a strategy for pressure ulcer prevention. , 2015, Clinical biomechanics.

[46]  Correlations between residual limb length and joint moments during sitting and standing movements in transfemoral amputees , 2016, Prosthetics and orthotics international.

[48]  Horst Heinrich Aschoff,et al.  Transcutaneous, distal femoral, intramedullary attachment for above-the-knee prostheses: an endo-exo device. , 2010, The Journal of bone and joint surgery. American volume.

[49]  Siamak Noroozi,et al.  A novel approach for assessing interfacial pressure between the prosthetic socket and the residual limb for below knee amputees using artificial neural networks , 2001, IJCNN'01. International Joint Conference on Neural Networks. Proceedings (Cat. No.01CH37222).

[50]  A Gefen,et al.  Patient-specific analyses of deep tissue loads post transtibial amputation in residual limbs of multiple prosthetic users. , 2009, Journal of biomechanics.

[51]  Ergin Tönük,et al.  Nonlinear viscoelastic material property estimation of lower extremity residual limb tissues. , 2004, Journal of biomechanical engineering.

[52]  V. C. Roberts,et al.  Triaxial force transducer for investigating stresses at the stump/socket interface , 2006, Medical and Biological Engineering and Computing.

[53]  J. Sanders,et al.  Clinical study: Changes in interface pressure and stump shape over time: Preliminary results from a transtibial amputee subject , 2000, Prosthetics and orthotics international.

[54]  L. Zheng,et al.  3D Finite Element Analysis of Bone Stress around Distally Osteointegrated Implant for Artificial Limb Attachment , 2007, Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi.

[55]  David J Atherton,et al.  A review of the pathophysiology, prevention and treatment of irritant diaper dermatitis , 2004, Current medical research and opinion.

[56]  T A Krouskop,et al.  Computer-aided design of a prosthetic socket for an above-knee amputee. , 1987, Journal of rehabilitation research and development.

[57]  J. Geertzen,et al.  Skin problems in lower limb amputees: an overview by case reports , 2007, Journal of the European Academy of Dermatology and Venereology : JEADV.

[58]  David R. Sinacore,et al.  Intermuscular Adipose Tissue Is Muscle Specific and Associated with Poor Functional Performance , 2012, Journal of aging research.

[59]  Caterina Rizzi,et al.  Automatic Below-Knee Prosthesis Socket Design: A Preliminary Approach , 2016, HCI.

[60]  G Papaioannou,et al.  Assessment of amputee socket-stump-residual bone kinematics during strenuous activities using Dynamic Roentgen Stereogrammetric Analysis. , 2010, Journal of biomechanics.

[61]  Jason M Wilken,et al.  A comparison of limb-socket kinematics of bone-bridging and non-bone-bridging wartime transtibial amputations. , 2012, The Journal of bone and joint surgery. American volume.

[62]  D S Childress,et al.  A review of prosthetic interface stress investigations. , 1996, Journal of rehabilitation research and development.

[63]  Caterina Rizzi,et al.  The role of simulation tools to innovate the prosthesis socket design process , 2007 .

[64]  S G Zachariah,et al.  Finite element estimates of interface stress in the trans-tibial prosthesis using gap elements are different from those using automated contact. , 2000, Journal of biomechanics.

[65]  Faisal Rafiq Mahmad Adikan,et al.  The Capability of Fiber Bragg Grating Sensors to Measure Amputees' Trans-Tibial Stump/Socket Interface Pressures , 2013, Sensors.

[66]  Mario C Faustini,et al.  The quasi-static response of compliant prosthetic sockets for transtibial amputees using finite element methods. , 2006, Medical engineering & physics.

[67]  Jason M Wilken,et al.  Axial bone–socket displacement for persons with a traumatic transtibial amputation: The effect of elevated vacuum suspension at progressive body-weight loads , 2016, Prosthetics and orthotics international.

[68]  S Derler,et al.  Influence of epidermal hydration on the friction of human skin against textiles , 2008, Journal of The Royal Society Interface.

[69]  Hanie Nadia Shasmin,et al.  In-Socket Sensory System for Transfemoral Amputees Using Piezoelectric Sensors: An Efficacy Study , 2016, IEEE/ASME Transactions on Mechatronics.

[70]  I. Siev-Ner,et al.  Surgical and Morphological Factors that Affect Internal Mechanical Loads in Soft Tissues of the Transtibial Residuum , 2009, Annals of Biomedical Engineering.

[71]  J.T. Peery,et al.  A Three-Dimensional Finite Element Model of the Transibial Residual Limb and Prosthetic Socket to Predict Skin Temperatures , 2006, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[72]  Marco Viceconti,et al.  Risk of failure during gait for direct skeletal attachment of a femoral prosthesis: a finite element study. , 2009, Medical engineering & physics.

[73]  L. Treloar,et al.  The elasticity of a network of long-chain molecules.—III , 1943 .

[74]  Gh. Pirouzi,et al.  Review of the Socket Design and Interface Pressure Measurement for Transtibial Prosthesis , 2014, TheScientificWorldJournal.

[75]  V. C. Roberts,et al.  Development of a non-linear finite element modelling of the below-knee prosthetic socket interface. , 1995, Medical engineering & physics.

[76]  C. Oomens,et al.  The effects of deformation, ischemia, and reperfusion on the development of muscle damage during prolonged loading. , 2011, Journal of applied physiology.

[77]  E. Tonuk,et al.  Nonlinear elastic material property estimation of lower extremity residual limb tissues , 2003, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[78]  A. Dickinson,et al.  Full-field in vitro measurements and in silico predictions of strain shielding in the implanted femur after total hip arthroplasty , 2015, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[79]  Hamish Mackie,et al.  Magnetic Resonance Imaging of Residual Soft Tissues for Computer-aided Technology Applications in Prosthetics—a Case Study , 1999 .

[80]  John Evans,et al.  Finite Element Modeling to Aid in Refining the Rehabilitation of Amputees Using Osseointegrated Prostheses , 2007, HCI.

[81]  Ming Zhang,et al.  Finite-element analysis to determine effect of monolimb flexibility on structural strength and interaction between residual limb and prosthetic socket. , 2004, Journal of rehabilitation research and development.

[82]  Ming Zhu,et al.  Finite element analysis of the contact interface between trans-femoral stump and prosthetic socket , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[83]  A. Gefen,et al.  Effects of sitting postures on risks for deep tissue injury in the residuum of a transtibial prosthetic-user: a biomechanical case study , 2011, Computer methods in biomechanics and biomedical engineering.

[84]  S G Zachariah,et al.  Interface mechanics in lower-limb external prosthetics: a review of finite element models. , 1996, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[85]  L. Treloar,et al.  Stress-strain data for vulcanised rubber under various types of deformation , 1944 .

[86]  K. Murray,et al.  Outcomes of knee disarticulation and the influence of surgical techniques in dysvascular patients: A systematic review , 2016, Prosthetics and orthotics international.

[87]  Amit Gefen,et al.  Viscoelastic properties of ovine adipose tissue covering the gluteus muscles. , 2007, Journal of biomechanical engineering.

[88]  M. Orendurff,et al.  Socket reaction moments in transtibial prostheses during walking at clinically perceived optimal alignment , 2016, Prosthetics and orthotics international.

[89]  S. Derler,et al.  Tribology of Skin: Review and Analysis of Experimental Results for the Friction Coefficient of Human Skin , 2011, Tribology Letters.

[90]  G. J. Verkerke,et al.  Experimental assessment of a new direct fixation implant for artificial limbs. , 2013, Journal of the mechanical behavior of biomedical materials.

[91]  D. Moher,et al.  Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement , 2009, BMJ.

[92]  Chih-Han Chang,et al.  A proposal for the pre‐evaluation protocol of below‐knee socket design - integration pain tolerance with finite element analysis , 2003 .

[93]  J. Paysant,et al.  Imaging of the painful lower limb stump. , 2000, Radiographics : a review publication of the Radiological Society of North America, Inc.

[94]  R. Baumgartner,et al.  Amputee stump radiology , 1980, Prosthetics and orthotics international.

[95]  Alternative Bone Graft Sources and Techniques for Tibiofibular Synostosis Creation Following Transtibial Amputation: A Report of Two Cases , 2015, JBJS case connector.

[96]  G. J. Verkerke,et al.  A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations , 2010, Annals of Biomedical Engineering.

[97]  Traumatic transfemoral amputation with concomitant ipsilateral proximal femoral fracture. A report of two cases. , 2007, The Journal of bone and joint surgery. American volume.

[98]  C. Oomens,et al.  The etiology of pressure ulcers: skin deep or muscle bound? , 2003, Archives of physical medicine and rehabilitation.

[99]  D. Childress,et al.  Normal and shear stresses on a residual limb in a prosthetic socket during ambulation: comparison of finite element results with experimental measurements. , 1993, Journal of rehabilitation research and development.

[100]  Stéphane Avril,et al.  Mixed experimental and numerical approach for characterizing the biomechanical response of the human leg under elastic compression. , 2010, Journal of biomechanical engineering.

[101]  Klaas Nicolay,et al.  Dynamic MRS and MRI of skeletal muscle function and biomechanics , 2006, NMR in Biomedicine.

[102]  Y. Itzchak,et al.  Strains and stresses in sub-dermal tissues of the buttocks are greater in paraplegics than in healthy during sitting. , 2008, Journal of biomechanics.

[103]  Dan L. Bader,et al.  The importance of internal strain as opposed to interface pressure in the prevention of pressure related deep tissue injury. , 2010, Journal of tissue viability.

[104]  Magnus Lilija,et al.  Proper Time for Definitive Transtibial Prosthetic Fitting , 1997 .

[105]  Xiaohong Jia,et al.  A quasi-dynamic nonlinear finite element model to investigate prosthetic interface stresses during walking for trans-tibial amputees. , 2005, Clinical biomechanics.

[106]  Joan E Sanders,et al.  Amputee socks: how does sock ply relate to sock thickness? , 2012, Prosthetics and orthotics international.

[107]  Hugh M. Herr,et al.  A Variable-Impedance Prosthetic Socket for a Transtibial Amputee Designed from Magnetic Resonance Imaging Data , 2013 .

[108]  Joan E Sanders,et al.  Amputee socks: Sock thickness changes with normal use , 2016, Prosthetics and orthotics international.

[109]  Joseph Alsousou,et al.  The AutoQual ultrasound elastography method for quantitative assessment of lateral strain in post-rupture Achilles tendons. , 2013, Journal of biomechanics.

[110]  S W Levy,et al.  Skin problems of the leg amputee. , 1980, Prosthetics and orthotics international.

[111]  A. Gefen,et al.  Real-Time Patient-Specific Finite Element Analysis of Internal Stresses in the Soft Tissues of a Residual Limb: A New Tool for Prosthetic Fitting , 2006, Annals of Biomedical Engineering.

[112]  A. Maniatty,et al.  Shear modulus reconstruction in dynamic elastography: time harmonic case , 2006, Physics in medicine and biology.

[113]  Andrew H Hansen,et al.  Cross-validation of a portable, six-degree-of-freedom load cell for use in lower-limb prosthetics research. , 2014, Journal of biomechanics.

[114]  Brad M Isaacson,et al.  Developing a Quantitative Measurement System for Assessing Heterotopic Ossification and Monitoring the Bioelectric Metrics from Electrically Induced Osseointegration in the Residual Limb of Service Members , 2010, Annals of Biomedical Engineering.

[115]  A. Mak,et al.  In vivo friction properties of human skin , 1999, Prosthetics and orthotics international.

[116]  O. Yeoh Some Forms of the Strain Energy Function for Rubber , 1993 .

[117]  F H Silver,et al.  Mechanical analysis of hypertrophic scar tissue: structural basis for apparent increased rigidity. , 1986, The Journal of investigative dermatology.

[118]  Glenn K. Klute,et al.  An interfacial stress sensor for biomechanical applications , 2012 .

[119]  A W Buis,et al.  Conventional patellar-tendon-bearing (PTB) socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a transtibial amputee , 1998, Prosthetics and orthotics international.

[120]  Peter R Worsley,et al.  Investigating the effects of strap tension during non-invasive ventilation mask application: a combined biomechanical and biomarker approach , 2016, Medical devices.

[121]  D L Bader,et al.  A pressure and shear sensor system for stress measurement at lower limb residuum/socket interface. , 2016, Medical engineering & physics.

[122]  M Zhang,et al.  Finite element modelling of a residual lower-limb in a prosthetic socket: a survey of the development in the first decade. , 1998, Medical engineering & physics.

[123]  Benjamin B. Wheatley,et al.  Fully non-linear hyper-viscoelastic modeling of skeletal muscle in compression , 2016, Computer methods in biomechanics and biomedical engineering.

[124]  A. Gefen,et al.  Strain-time cell-death threshold for skeletal muscle in a tissue-engineered model system for deep tissue injury. , 2008, Journal of biomechanics.

[125]  Amit Gefen,et al.  Real-time subject-specific analyses of dynamic internal tissue loads in the residual limb of transtibial amputees. , 2010, Medical engineering & physics.

[126]  Amit Gefen,et al.  How do microclimate factors affect the risk for superficial pressure ulcers: a mathematical modeling study. , 2011, Journal of tissue viability.

[127]  Rickard Brånemark,et al.  Load on Osseointegrated Fixation of a Transfemoral Amputee During a Fall: Loading, Descent, Impact and Recovery Analysis , 2010, Prosthetics and orthotics international.

[128]  Antonio Fiorentino,et al.  Potential of modeling and simulations of bioengineered devices: Endoprostheses, prostheses and orthoses , 2016, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[129]  T. Öberg,et al.  Morphological changes during early trans-tibial prosthetic fitting , 1998, Prosthetics and orthotics international.

[130]  K. Hagberg,et al.  A novel osseointegrated percutaneous prosthetic system for the treatment of patients with transfemoral amputation: A prospective study of 51 patients. , 2014, The bone & joint journal.

[131]  Georges Limbert,et al.  A mechanistic insight into the mechanical role of the stratum corneum during stretching and compression of the skin. , 2015, Journal of the mechanical behavior of biomedical materials.

[132]  Cwj Cees Oomens,et al.  A numerical‐experimental method to characterize the non‐linear mechanical behaviour of human skin , 2003, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[133]  Joan E. Sanders,et al.  Stump-Socket Interface Conditions , 2005 .

[134]  Amit Gefen,et al.  Stress relaxation of porcine gluteus muscle subjected to sudden transverse deformation as related to pressure sore modeling. , 2006, Journal of biomechanical engineering.

[135]  N. Simpson,et al.  Follicular keratoses at amputation sites , 1994, The British journal of dermatology.

[136]  S. Avril,et al.  Identification of the material parameters of soft tissues in the compressed leg , 2012, Computer methods in biomechanics and biomedical engineering.

[137]  A Gefen,et al.  In vivo muscle stiffening under bone compression promotes deep pressure sores. , 2005, Journal of biomechanical engineering.

[138]  Rory A Cooper,et al.  Review of research on prosthetic devices for lower extremity amputation. , 2006, Critical reviews in biomedical engineering.

[139]  P R Worsley,et al.  Monitoring contractile dermal lymphatic activity following uniaxial mechanical loading. , 2016, Medical engineering & physics.

[140]  Laurent A. Frossard,et al.  Osseointegrated prosthetic limb for amputees: Single stage surgery , 2015 .

[141]  M. A. G. S. Pinto,et al.  Fibular segment bone bridging in trans-tibial amputation , 2004, Prosthetics and orthotics international.

[142]  F P T Baaijens,et al.  Compression-induced damage and internal tissue strains are related. , 2008, Journal of biomechanics.

[143]  K. Hagberg,et al.  Comparison of prosthetic costs and service between osseointegrated and conventional suspended transfemoral prostheses , 2013, Prosthetics and orthotics international.

[144]  William R Ledoux,et al.  Residual-limb skin temperature in transtibial sockets. , 2005, Journal of rehabilitation research and development.

[145]  Cees W J Oomens,et al.  A new method to evaluate the effects of shear on the skin , 2015, Wound repair and regeneration : official publication of the Wound Healing Society [and] the European Tissue Repair Society.

[146]  Damien Lacroix,et al.  Finite Element Analysis of Donning Procedure of a Prosthetic Transfemoral Socket , 2011, Annals of Biomedical Engineering.

[147]  Juan Fernando Ramírez,et al.  Incidence of the boundary condition between bone and soft tissue in a finite element model of a transfemoral amputee , 2012, Prosthetics and orthotics international.

[148]  Gijsbertus Jacob Verkerke,et al.  Simulated bone remodeling around two types of osseointegrated implants for direct fixation of upper-leg prostheses. , 2012, Journal of the mechanical behavior of biomedical materials.

[149]  V. Neumann,et al.  Stump Ulcers and Continued Prosthetic Limb Use , 2006, Prosthetics and orthotics international.

[150]  W. Lee,et al.  Load transfer mechanics between trans-tibial prosthetic socket and residual limb--dynamic effects. , 2004, Journal of biomechanics.

[151]  A. Khemka,et al.  Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases , 2015, Acta orthopaedica.

[152]  R. Gailey,et al.  Review of secondary physical conditions associated with lower-limb amputation and long-term prosthesis use. , 2008, Journal of rehabilitation research and development.

[153]  Y. Itzchak,et al.  Assessment of mechanical conditions in sub-dermal tissues during sitting: a combined experimental-MRI and finite element approach. , 2007, Journal of biomechanics.

[154]  B. Rydevik,et al.  Osseointegration in skeletal reconstruction and rehabilitation: a review. , 2001, Journal of rehabilitation research and development.

[155]  F. S. Vinson,et al.  A pulsed Doppler ultrasonic system for making noninvasive measurements of the mechanical properties of soft tissue. , 1987, Journal of rehabilitation research and development.

[156]  R. Brånemark,et al.  Effect of load on the bone around bone‐anchored amputation prostheses , 2017, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[157]  Dan L. Bader,et al.  Characterisation of dynamic couplings at lower limb residuum/socket interface using 3D motion capture. , 2015, Medical engineering & physics.

[158]  C. W. J. Oomens,et al.  Temporal Effects of Mechanical Loading on Deformation-Induced Damage in Skeletal Muscle Tissue , 2010, Annals of Biomedical Engineering.

[159]  John H. Evans,et al.  Development and preliminary testing of a device for the direct measurement of forces and moments in the prosthetic limb of transfemoral amputees during activities of daily living , 2003 .

[160]  M. Zhang,et al.  Comparison of computational analysis with clinical measurement of stresses on below-knee residual limb in a prosthetic socket. , 2000, Medical engineering & physics.

[161]  G. M. Rommers,et al.  A study of technical changes to lower limb prostheses after initial fitting , 2000, Prosthetics and orthotics international.

[162]  A W Buis,et al.  Calibration problems encountered while monitoring stump/socket interface pressures with force sensing resistors: Techniques adopted to minimise inaccuracies , 1997, Prosthetics and orthotics international.

[163]  G Paré,et al.  Introducing information technology in the clinical setting. Lessons learned in a trauma center. , 1998, International journal of technology assessment in health care.

[164]  Sheridan Laing,et al.  Engineering a trans-tibial prosthetic socket for the lower limb amputee. , 2011, Annals of the Academy of Medicine, Singapore.

[165]  R. Rivlin Large elastic deformations of isotropic materials IV. further developments of the general theory , 1948, Philosophical Transactions of the Royal Society of London. Series A, Mathematical and Physical Sciences.

[166]  Pierre Badel,et al.  Prediction of the Biomechanical Effects of Compression Therapy on Deep Veins Using Finite Element Modelling , 2015, Annals of Biomedical Engineering.

[167]  A. Toro,et al.  Experimental assessment of friction coefficient between polypropylene and human skin using instrumented sclerometer , 2015 .

[168]  Tomáš Návrat,et al.  Finite element analysis for the evaluation of the structural behaviour, of a prosthesis for trans-tibial amputees. , 2012, Medical engineering & physics.

[169]  Robert S. MacLeod,et al.  Establishing Multiscale Models for Simulating Whole Limb Estimates of Electric Fields for Osseointegrated Implants , 2011, IEEE Transactions on Biomedical Engineering.

[170]  Arianna Menciassi,et al.  Pressure mapping with textile sensors for compression therapy monitoring , 2016, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[171]  M. Lilja,et al.  Relaxed versus activated stump muscles during casting for trans-tibial prostheses , 1999, Prosthetics and orthotics international.

[172]  R. Ogden Large deformation isotropic elasticity – on the correlation of theory and experiment for incompressible rubberlike solids , 1972, Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences.

[173]  Ming Zhang,et al.  Using computational simulation to aid in the prediction of socket fit: a preliminary study. , 2007, Medical engineering & physics.

[174]  T Y Shiang,et al.  The effect of insoles in therapeutic footwear--a finite element approach. , 1997, Journal of biomechanics.

[175]  Cwj Cees Oomens,et al.  Which factors influence the ability of a computational model to predict the in vivo deformation behaviour of skeletal muscle? , 2013, Computer methods in biomechanics and biomedical engineering.

[176]  T. Krouskop,et al.  The effects of pylon shape on bone-pylon interface performance in direct skeletal attachment. , 1976, Journal of biomedical materials research.