3D vessel axis extraction using 2D calibrated x-ray projections for coronary modeling

A new approach for 3D vessel centreline extraction using multiple, ECG-gated, calibrated X-ray angiographic projections of the coronary arteries is described. The proposed method performs direct extraction of 3D vessel centrelines, without the requirement to either first compute prior 2D centreline estimates, or perform a complete volume reconstruction. A front propagation-based algorithm, initialised with one or more 3D seed points, is used to explore a volume of interest centred on the projection geometry's isocentre. The expansion of a 3D region is controlled by forward projecting boundary points into all projection images to compute vessel response measurements, which are combined into a 3D propagation speed so that the front expands rapidly when all projection images yield high vessel responses. Vessel centrelines are obtained by reconstructing the paths of fastest propagation. Based on these axes, a volume model of the coronaries can be constructed by forward projecting axis points into the 2D images where the borders are detected. The accuracy of the method was demonstrated via a comparison of automatically extracted centrelines with 3D centrelines derived from manually segmented projection data.

[1]  Max A. Viergever,et al.  Quantitative analysis of 3D coronary modeling in 3D rotational X-ray imaging , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[2]  C. Metz,et al.  Determination of three-dimensional structure in biplane radiography without prior knowledge of the relationship between the two views: theory. , 1989, Medical physics.

[3]  Y Sun,et al.  Automated identification of vessel contours in coronary arteriograms by an adaptive tracking algorithm. , 1989, IEEE transactions on medical imaging.

[4]  Milan Sonka,et al.  Robust simultaneous detection of coronary borders in complex images , 1995, IEEE Trans. Medical Imaging.

[5]  Shmuel Einav,et al.  Evaluation of center-line extraction algorithms in quantitative coronary angiography , 2001, IEEE Transactions on Medical Imaging.

[6]  Sun Zheng 3D Reconstruction of Coronary Arterial Tree , 2004 .

[7]  Andreas Wahle,et al.  Assessment of diffuse coronary artery disease by quantitative analysis of coronary morphology based upon 3-D reconstruction from biplane angiograms , 1995, IEEE Trans. Medical Imaging.

[8]  Hui Zhu,et al.  Tracking 3-D coronary artery motion with biplane angiography , 2002, Proceedings IEEE International Symposium on Biomedical Imaging.

[9]  Jürgen Weese,et al.  A Multi-scale Line Filter with Automatic Scale Selection Based on the Hessian Matrix for Medical Image Segmentation , 1997, Scale-Space.

[10]  Kostas Haris,et al.  Model-based morphological segmentation and labeling of coronary angiograms , 1999, IEEE Transactions on Medical Imaging.

[11]  S. M. Collins,et al.  Automated analysis of coronary arterial morphology in cineangiograms: geometric and physiologic validation in humans. , 1989, IEEE transactions on medical imaging.

[12]  James A. Sethian,et al.  A real-time algorithm for medical shape recovery , 1998, Sixth International Conference on Computer Vision (IEEE Cat. No.98CH36271).

[13]  Jürgen Weese,et al.  Vessel Segmentation for Visualization of MRA with Blood Pool Contrast Agent , 2001, MICCAI.

[14]  Tony Lindeberg,et al.  Edge Detection and Ridge Detection with Automatic Scale Selection , 1996, Proceedings CVPR IEEE Computer Society Conference on Computer Vision and Pattern Recognition.