Abstract The air exchange in rainscreen walls is expected to provide ventilation drying if excess moisture is absorbed in the wall construction. In an earlier paper, we presented a cavity airflow model and measurement based estimations of air change rates (ACH) in south-facing experimental walls. Here, focus is on the ventilation drying process and its practical implications. ACH in the experimental walls were calculated and converted into drying rates at different stages in the drying process. Furthermore, changes in the drying rates due to changes in the cavity design and in the outdoor climate were investigated. The significance of the drying rates was demonstrated in a case study. Findings showed that the cavity design is of major importance for the drying rate if the material adjacent to the cavity is wet over its entire extension. For such extreme cases, a light facade colour, vented horizontal battens and, in particular, a small cavity depth, are adverse factors for the drying rate. As the drying process proceeds and the moisture transport from the material to the cavity air becomes dependent on vapour diffusion, the drying rates for different cavity designs tend to be evened out. If the resistance to vapour flow in the material reaches high levels, a favourable outdoor climate is significantly more important than the cavity design to promote drying. Also for the case where the material adjacent to the cavity initially is only locally wet, findings showed that the cavity design is of minor importance for the drying time.
[1]
Bje Bert Blocken,et al.
On CFD simulation of wind-induced airflow in narrow ventilated facade cavities: coupled and decoupled simulations and modelling limitations
,
2010
.
[2]
Carl-Eric Hagentoft.
Introduction to Building Physics
,
2001
.
[3]
Jelena Srebric,et al.
Modeling convective drying of ventilated wall chambers in building enclosures
,
2006
.
[4]
Mark Bassett,et al.
Ventilation Measured in the Wall Cavities of High Moisture Risk Buildings
,
2009
.
[5]
Kjartan Gudmundsson,et al.
The drying out capacity of a ventilated internal cavity with a heating cable, analytical model and empirical verification
,
2012
.
[6]
Jörgen Falk,et al.
Ventilated rainscreen cladding: Measurements of cavity air velocities, estimation of air change rates and evaluation of driving forces
,
2013
.
[7]
Jelena Srebric,et al.
Analytical procedures for estimating airflow rates in ventilated, screened wall systems (VSWS)
,
2012
.
[8]
J. Whitelaw,et al.
Convective heat and mass transfer
,
1966
.
[9]
Dirk Saelens,et al.
Experimental Evaluation of Airflow in Naturally Ventilated Active Envelopes
,
2001
.