Potential of Mid-Infrared Spectroscopy for On-Line Monitoring of Mammalian Cell Culture Medium Components

This study proposed a methodology to evaluate the potential of midinfrared (MIR) spectroscopy as a process analytical technology (PAT) tool for in situ (in-line) monitoring of cell culture media constituents, paving the way for on-line bioprocess monitoring and control of mammalian cell cultures. The methodology included a limit of detection (LOD) analysis and external influence investigation in addition to the calibration model development. The LOD analysis in the initial step provided a detailed procedure by which to evaluate the monitoring potential of the instrument of choice, for the application in question. The external influence study highlighted the potential difficulties when applying this technique to a typical mammalian cell culture. A comparative investigation between a fixed conduit immersion probe and flexible fiber-optic immersion probe was also carried out. Limitations associated with the use of MIR spectroscopy in the cell culture environment were also examined. A preliminary investigation, on components typically found in mammalian cell cultures, involving spectral characterization and limit of detection analysis was completed. It was evident at this initial stage that glutamine, could not be accurately detected at levels typically found in a mammalian cell culture medium. Results for glucose and ammonia, however, proved promising. A seven-concentration-level experimental design was used, and partial least squares regression employed, to develop calibration models. Optimized model results echoed the results of the preliminary analysis with the percentage error of prediction for glucose as low as 6.03% with the fixed conduit probe and glutamine having a higher error of 63.06% for the same probe. Comparison of the model results obtained from both probes supported the fixed conduit as the more accurate of the two probes for this experimental setup. The effect of external influences on the MIR spectra and hence the concentrations predicted by the model were also examined. These were subjected to statistical analysis to determine the significance of the effect. This study demonstrates that MIR spectroscopy as a PAT tool has limited potential for mammalian cell culture monitoring due to low concentrations of analytes present and outlines a method to allow the system to be evaluated.

[1]  Gerard Downey,et al.  Attempted confirmation of the provenance of Corsican PDO honey using FT-IR spectroscopy and multivariate data analysis. , 2010, Journal of agricultural and food chemistry.

[2]  I. Marison,et al.  Real‐time update of calibration model for better monitoring of batch processes using spectroscopy , 2004, Biotechnology and bioengineering.

[3]  Mark A Arnold,et al.  On‐line monitoring of human prostate cancer cells in a perfusion rotating wall vessel by near‐infrared spectroscopy , 2004, Biotechnology and bioengineering.

[4]  Nanna Petersen,et al.  In situ near infrared spectroscopy for analyte‐specific monitoring of glucose and ammonium in streptomyces coelicolor fermentations , 2010, Biotechnology progress.

[5]  Luis A. Sarabia,et al.  Capability of detection of an analytical method evaluating false positive and false negative (ISO 11843) with partial least squares , 2003 .

[6]  Anurag S Rathore,et al.  Roadmap for implementation of quality by design (QbD) for biotechnology products. , 2009, Trends in biotechnology.

[7]  P. Dhamelincourt,et al.  Polarized Micro-Raman and FT-IR Spectra of L-Glutamine , 1993 .

[8]  J. Jobson Applied Multivariate Data Analysis , 1995 .

[9]  E. Tamburini,et al.  Near-Infrared Spectroscopy: A Tool for Monitoring Submerged Fermentation Processes Using an Immersion Optical-Fiber Probe , 2003, Applied spectroscopy.

[10]  Carl-Fredrik Mandenius,et al.  Quality-by-design for biotechnology-related pharmaceuticals. , 2009, Biotechnology journal.

[11]  Geovanni Martinez,et al.  Optical inline measurement procedures for counting and sizing cells in bioprocess technology. , 2009, Advances in biochemical engineering/biotechnology.

[12]  A K Smilde,et al.  Influence of temperature on vibrational spectra and consequences for the predictive ability of multivariate models. , 1998, Analytical chemistry.

[13]  Gerard L. Coté,et al.  Investigation of Near-Infrared Spectroscopy for Periodic Determination of Glucose in Cell Culture Media in Situ , 2000 .

[14]  H. Goicoechea,et al.  Monitoring substrate and products in a bioprocess with FTIR spectroscopy coupled to artificial neural networks enhanced with a genetic-algorithm-based method for wavelength selection. , 2006, Talanta.

[15]  S. Sivakesava,et al.  Simultaneous determination of multiple components in lactic acid fermentation using FT-MIR, NIR, and FT-Raman spectroscopic techniques , 2001 .

[16]  James K. Drennen Quality by Design—What Does it Really Mean? , 2007, Journal of Pharmaceutical Innovation.

[17]  P. Salmon,et al.  Real-time analyte monitoring of a fungal fermentation, at pilot scale, using in situ mid-infrared spectroscopy , 2001 .

[18]  B. Lendl,et al.  On-Line Fermentation Monitoring by Mid-Infrared Spectroscopy , 2004, Applied spectroscopy.

[19]  N. M. Faber,et al.  Uncertainty estimation and figures of merit for multivariate calibration (IUPAC Technical Report) , 2006 .

[20]  Daniel Picque,et al.  On-line monitoring of fermentation processes by a new remote dispersive middle-infrared spectrometer , 2000 .

[21]  Bernd Hitzmann,et al.  On-line infrared spectroscopy for bioprocess monitoring , 2010, Applied Microbiology and Biotechnology.

[22]  Reginald H. Wilson,et al.  Fourier transform mid-infrared spectroscopy for food analysis , 1990 .

[23]  Brian McNeil,et al.  In‐situ near infrared spectroscopy to monitor key analytes in mammalian cell cultivation , 2003, Biotechnology and bioengineering.

[24]  Urs von Stockar,et al.  Real-time in situ monitoring of freely suspended and immobilized cell cultures based on mid-infrared spectroscopic measurements. , 2002, Biotechnology and bioengineering.

[25]  Michal Dabros,et al.  On-Line Recalibration of Spectral Measurements Using Metabolite Injections and Dynamic Orthogonal Projection , 2007, Applied spectroscopy.

[26]  Brian McNeil,et al.  Near‐infrared spectroscopic monitoring of biomass, glucose, ethanol and protein content in a high cell density baker's yeast fed‐batch bioprocess , 2006, Yeast.

[27]  Linda M. Harvey,et al.  At-line monitoring of ammonium, glucose, methyl oleate and biomass in a complex antibiotic fermentation process using attenuated total reflectance-mid-infrared (ATR-MIR) spectroscopy , 2006 .

[28]  Urs von Stockar,et al.  Simplified Fourier-transform mid-infrared spectroscopy calibration based on a spectra library for the on-line monitoring of bioprocesses. , 2007, Analytica chimica acta.

[29]  Urs von Stockar,et al.  On-line monitoring of nine different batch cultures of E. coli by mid-infrared spectroscopy, using a single spectra library for calibration. , 2008, Journal of biotechnology.

[30]  Urs von Stockar,et al.  The influence of correlated calibration samples on the prediction performance of multivariate models based on mid-infrared spectra of animal cell cultures. , 2002, Analytical chemistry.

[31]  John Arul Phillips,et al.  In Situ Monitoring of an Escherichia coli Fermentation Using a Diamond Composition ATR Probe and Mid‐infrared Spectroscopy , 1999, Biotechnology progress.

[32]  Richard G. Brereton,et al.  Applied Chemometrics for Scientists , 2007 .

[33]  Emma Petiot,et al.  In situ quantification of microcarrier animal cell cultures using near-infrared spectroscopy ☆ , 2010 .

[34]  Urs von Stockar,et al.  pH prediction and control in bioprocesses using mid‐infrared spectroscopy , 2008, Biotechnology and bioengineering.

[35]  Henri S. Tapp,et al.  Mid-infrared spectroscopy for food analysis: recent new applications and relevant developments in sample presentation methods , 1999 .

[36]  Brian McNeil,et al.  Multiplexing fibre optic near infrared (NIR) spectroscopy as an emerging technology to monitor industrial bioprocesses. , 2007, Analytica chimica acta.

[37]  Tormod Næs,et al.  A user-friendly guide to multivariate calibration and classification , 2002 .

[38]  Richard G. Brereton,et al.  Partial factorial designs for multivariate calibration: extension to seven levels and comparison of strategy , 1998 .

[39]  Mark A. Arnold,et al.  Simultaneous Measurements of Glucose, Glutamine, Ammonia, Lactate, and Glutamate in Aqueous Solutions by Near-Infrared Spectroscopy , 1996 .

[40]  Urs von Stockar,et al.  A simple method to monitor and control methanol feeding of Pichia pastoris fermentations using mid-IR spectroscopy. , 2007, Journal of biotechnology.

[41]  Michael J. McShane,et al.  Near-Infrared Spectroscopy for Determination of Glucose, Lactate, and Ammonia in Cell Culture Media , 1998 .

[42]  J. Jobson,et al.  Applied Multivariate Data Analysis: Regression and Experimental Design , 1999 .

[43]  M. C. Ortiz,et al.  DETARCHI: A program for detection limits with specified assurance probabilities and characteristic curves of detection , 1994 .

[44]  Joaquim M. S. Cabral,et al.  Real-time bioprocess monitoring: Part I: In situ sensors , 2006 .