Resistivity probing of multi-layered tissue phantoms using microelectrodes.

We present the use of an array of rectangular microelectrodes to discriminate between different resistivities in a thin, layered sample. Each electrode was 8 mm long and 200 nm thick. The electrode widths ranged from 20 to 500 microm. The electrodes were designed such that all pairs of consecutive electrodes had the same relative geometry, and therefore identical cell constants. A hydrogel-based tissue phantom, made by photopolymerization of 2-hydroxyethyl methacrylate (HEMA), was developed. By changing the hydrogel composition and the ionic strength of the storage medium, the resistivity of the hydrogels could be tuned between 100 omegam and 100 komegam. Using bipolar measurements, the tissue phantoms were characterized in the frequency range from 100 Hz to 30 MHz. The relative resistivity distribution of a three-layered structure composed of 120 microm sheets could be calculated and was shown to agree to within 7% of the bulk measurements. Potential clinical applications for this technique include probing of epithelial tissue and skin cancer screening.

[1]  J Jossinet,et al.  The impedivity of freshly excised human breast tissue , 1998, Physiological measurement.

[2]  D S Holder,et al.  Some practical biological phantoms for calibrating multifrequency electrical impedance tomography. , 1996, Physiological measurement.

[3]  Brian H. Brown,et al.  Bipolar and tetrapolar transfer impedance measurements from volume conductor , 2000 .

[4]  E L Madsen,et al.  Anthropomorphic 1H MRS head phantom. , 1998, Medical physics.

[5]  Stig Ollmar,et al.  Methods of information extraction from impedance spectra of biological tissue, in particular skin and oral mucosa—a critical review and suggestions for the future , 1998 .

[6]  D C Barber,et al.  Impedance imaging using linear electrode arrays. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[7]  J. K. Vij,et al.  Fourier transform infrared study of poly (2-hydroxyethyl methacrylate) PHEMA , 1997 .

[8]  J Rosell,et al.  Electrical impedance tomography of the eye: in vitro measurements of the cornea and the lens. , 1996, Physiological measurement.

[9]  Boris Rubinsky,et al.  A feasibility study for electrical impedance tomography as a means to monitor tissue electroporation for molecular medicine , 2002, IEEE Transactions on Biomedical Engineering.

[10]  D. Hukins,et al.  Rheological properties of poly(2-hydroxyethyl methacrylate) (pHEMA) as a function of water content and deformation frequency , 2003, Journal of materials science. Materials in medicine.

[11]  Toyoichi Tanaka,et al.  Volume phase transition in a nonionic gel , 1984 .

[12]  G. P. Johari,et al.  X-ray and neutron scattering studies of the structure of water in a hydrogel , 1992 .

[13]  P. Bergveld,et al.  Theoretical and experimental determination of cell constants of planar-interdigitated electrolyte conductivity sensors , 1995 .

[14]  T. Faes,et al.  Electrical impedance tomography to measure pulmonary perfusion: is the reproducibility high enough for clinical practice? , 2003, Physiological measurement.

[15]  Zhenyu Guo,et al.  A review of electrical impedance techniques for breast cancer detection. , 2003, Medical engineering & physics.

[16]  N. Peppas,et al.  Hydrogels in Pharmaceutical Formulations , 1999 .

[17]  G. Bayramoglu,et al.  Congo Red attached monosize poly(HEMA-co-MMA) microspheres for use in reversible enzyme immobilisation , 2002 .

[18]  G. Somorjai,et al.  AFM and SFG studies of pHEMA-based hydrogel contact lens surfaces in saline solution: adhesion, friction, and the presence of non-crosslinked polymer chains at the surface. , 2002, Biomaterials.

[19]  O. Wichterle,et al.  Hydrophilic Gels for Biological Use , 1960, Nature.

[20]  T V Chirila,et al.  An overview of the development of artificial corneas with porous skirts and the use of PHEMA for such an application. , 2001, Biomaterials.

[21]  J. Vogt,et al.  Soft contact lens polymers: an evolution. , 2001, Biomaterials.

[22]  David Isaacson,et al.  Electrical Impedance Tomography , 1999, SIAM Rev..

[23]  K. Osasa,et al.  Dewatering of Gels by Constant Pressure Expression , 1994 .

[24]  P. Jacobs,et al.  Design optimisation of planar electrolytic conductivity sensors , 2006, Medical and Biological Engineering and Computing.

[25]  Ronald A. Siegel,et al.  pH-Dependent Equilibrium Swelling Properties of Hydrophobic Polyelectrolyte Copolymer Gels , 1988 .

[26]  J. D. Bourland,et al.  Tetrapolar electrode system for measuring physiological events by impedance , 2006, Medical and Biological Engineering and Computing.

[27]  Lauren Flynn,et al.  Fiber templating of poly(2-hydroxyethyl methacrylate) for neural tissue engineering. , 2003, Biomaterials.

[28]  Richard H. Bayford,et al.  Three-Dimensional Electrical Impedance Tomography of Human Brain Activity , 2001, NeuroImage.

[29]  W. Hilberg,et al.  From Approximations to Exact Relations for Characteristic Impedances , 1969 .

[30]  Toyoichi Tanaka,et al.  Swelling of Ionic Gels : Quantitative Performance of the Donnan Theory , 1984 .

[31]  J. V. Hatfield,et al.  Silicon-based miniature sensor for electrical tomography , 2004 .

[32]  P. Dalton,et al.  The effect of synthesis conditions on the properties of poly(2-hydroxyethyl methacrylate) sponges , 1998 .

[33]  B. Brown,et al.  Applied potential tomography: possible clinical applications. , 1985, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[34]  B. Blad,et al.  Impedance spectra of tumour tissue in comparison with normal tissue; a possible clinical application for electrical impedance tomography. , 1996, Physiological measurement.

[35]  K. Anseth,et al.  Photopolymerization of multilaminated poly(HEMA) hydrogels for controlled release. , 1999, Journal of controlled release : official journal of the Controlled Release Society.

[36]  O. Teschke,et al.  Interfacial water dielectric-permittivity-profile measurements using atomic force microscopy. , 2001, Physical review. E, Statistical, nonlinear, and soft matter physics.

[37]  C. Young,et al.  Fabrication and characteristics of polyHEMA artificial skin with improved tensile properties , 1998 .

[38]  R H Bayford,et al.  Electrical impedance tomography spectroscopy (EITS) for human head imaging. , 2003, Physiological measurement.

[39]  M. Lesho,et al.  A method for studying swelling kinetics based on measurement of electrical conductivity , 1998 .

[40]  J. Bronzwaer,et al.  Determination of stroke volume by means of electrical impedance tomography. , 2000, Physiological measurement.