Moving Enzyme-Linked ImmunoSorbent Assay to the Point-of-Care Dry- Reagent Strip Biosensors
暂无分享,去创建一个
Guodong Liu | Hui Xu | A. Kawde | Guodong Liu | X. Mao | Qingxiang Zeng | Yuqing He | Xun Mao | Hui Xu | Qingxiang Zeng | Abdel-Nasser Kawde | Yuqing He
[1] R. Lequin. Enzyme immunoassay (EIA)/enzyme-linked immunosorbent assay (ELISA). , 2005, Clinical chemistry.
[2] Yunqing Ma,et al. Disposable nucleic acid biosensors based on gold nanoparticle probes and lateral flow strip. , 2009, Analytical chemistry.
[3] Il-Hoon Cho,et al. An enzyme immunoanalytical system based on sequential cross-flow chromatography. , 2005, Analytical chemistry.
[4] P. Collinson,et al. The need for a point of care testing: an evidence-based appraisal. , 1999, Scandinavian journal of clinical and laboratory investigation. Supplementum.
[5] Guodong Liu,et al. Multiplex electrochemical immunoassay using gold nanoparticle probes and immunochromatographic strips , 2008 .
[6] R. Durst,et al. Immunosensor for extra-lab measurements based on liposome amplification and capillary migration. , 1993, Biosensors & bioelectronics.
[7] Ke Chen,et al. An electrochemical stripping metalloimmunoassay based on silver-enhanced gold nanoparticle label. , 2005, Biosensors & bioelectronics.
[8] Chang-Hoon Han,et al. Development of ELISA and immunochromatographic assay for the detection of gentamicin. , 2005, Journal of agricultural and food chemistry.
[9] H. Nariuchi,et al. A highly sensitive quantitative immunochromatography assay for antigen-specific IgE. , 2003, Journal of immunological methods.
[10] M. Weller,et al. Immunochromatographic techniques – a critical review , 2000, Fresenius' journal of analytical chemistry.
[11] Yuehe Lin,et al. Nanovehicles Based Bioassay Labels , 2007 .
[12] Yuehe Lin,et al. Nanomaterial labels in electrochemical immunosensors and immunoassays. , 2007, Talanta.
[13] Il-Hoon Cho,et al. Plastic ELISA-on-a-chip based on sequential cross-flow chromatography. , 2006, Analytical chemistry.
[14] Guodong Liu,et al. Disposable electrochemical immunosensor diagnosis device based on nanoparticle probe and immunochromatographic strip. , 2007, Analytical chemistry.
[15] Joseph Wang,et al. Point-of-care biosensor systems for cancer diagnostics/prognostics. , 2006, Biosensors & bioelectronics.
[16] Guodong Liu,et al. Aptamer-functionalized gold nanoparticles as probes in a dry-reagent strip biosensor for protein analysis. , 2009, Analytical chemistry.
[17] J. Park,et al. Disposable liposome immunosensor for theophylline combining an immunochromatographic membrane and a thick-film electrode , 1999 .
[18] C. Heeschen,et al. Evaluation of a rapid whole blood ELISA for quantification of troponin I in patients with acute chest pain. , 1999, Clinical chemistry.
[19] Y. Kitaura,et al. Development of a simple whole blood panel test for detection of human heart-type fatty acid-binding protein. , 2001, Clinical biochemistry.
[20] E. F. Ullman,et al. Enzyme immunochromatography--a quantitative immunoassay requiring no instrumentation. , 1985, Clinical chemistry.