Moving Enzyme-Linked ImmunoSorbent Assay to the Point-of-Care Dry- Reagent Strip Biosensors

In this work, we described a point-of-care (POC) dry-reagent strip biosensor (DRSB) based on enzyme tracers and portable strip reader for simple, low-cost and sensitive assay of protein detection in minutes. Horseradish Peroxidase (HRP) and Rabbit IgG (R-IgG) were used as a model system for the demonstration of the proof-of-concept. The sandwich-type immunoreactions were performed on the DRSB and the HRP tracers were captured on the test zone of the biosensor. The excess of HRP tracers were captured on the control zone of the biosensor through the immobilized secondary antibody. Subsequent enzymatic reaction in the presence of the substrate produced insoluble enzymatic products, which deposited on both test and control zones of the DRSB and formed two characteristics blue bands. While qualitative tests are realized by observing the color change of the test zone, quantitative data are obtained by recording the intensities of the test zone with a portable “strip reader”. The quantitative response of the optimized DRSB over the range of 0.1-50 ng mL -1 IgG in association with a 10-min assay time is obtained, and the limit of detection is estimated to be 0.05 ng/mL, which is ten times lower than that of the gold nanoparticle (GNP)-based DRSB. The enzyme-based DRSB was used to detect Carcinoembryonic Antigen (CEA) biomarker in human plasma successfully. Such enzyme-based DRSB offers a simple and fast tool for point-of-care protein assay and a potential substituent for the traditional Enzyme-linked Immunosorbent Assay (ELISA).

[1]  R. Lequin Enzyme immunoassay (EIA)/enzyme-linked immunosorbent assay (ELISA). , 2005, Clinical chemistry.

[2]  Yunqing Ma,et al.  Disposable nucleic acid biosensors based on gold nanoparticle probes and lateral flow strip. , 2009, Analytical chemistry.

[3]  Il-Hoon Cho,et al.  An enzyme immunoanalytical system based on sequential cross-flow chromatography. , 2005, Analytical chemistry.

[4]  P. Collinson,et al.  The need for a point of care testing: an evidence-based appraisal. , 1999, Scandinavian journal of clinical and laboratory investigation. Supplementum.

[5]  Guodong Liu,et al.  Multiplex electrochemical immunoassay using gold nanoparticle probes and immunochromatographic strips , 2008 .

[6]  R. Durst,et al.  Immunosensor for extra-lab measurements based on liposome amplification and capillary migration. , 1993, Biosensors & bioelectronics.

[7]  Ke Chen,et al.  An electrochemical stripping metalloimmunoassay based on silver-enhanced gold nanoparticle label. , 2005, Biosensors & bioelectronics.

[8]  Chang-Hoon Han,et al.  Development of ELISA and immunochromatographic assay for the detection of gentamicin. , 2005, Journal of agricultural and food chemistry.

[9]  H. Nariuchi,et al.  A highly sensitive quantitative immunochromatography assay for antigen-specific IgE. , 2003, Journal of immunological methods.

[10]  M. Weller,et al.  Immunochromatographic techniques – a critical review , 2000, Fresenius' journal of analytical chemistry.

[11]  Yuehe Lin,et al.  Nanovehicles Based Bioassay Labels , 2007 .

[12]  Yuehe Lin,et al.  Nanomaterial labels in electrochemical immunosensors and immunoassays. , 2007, Talanta.

[13]  Il-Hoon Cho,et al.  Plastic ELISA-on-a-chip based on sequential cross-flow chromatography. , 2006, Analytical chemistry.

[14]  Guodong Liu,et al.  Disposable electrochemical immunosensor diagnosis device based on nanoparticle probe and immunochromatographic strip. , 2007, Analytical chemistry.

[15]  Joseph Wang,et al.  Point-of-care biosensor systems for cancer diagnostics/prognostics. , 2006, Biosensors & bioelectronics.

[16]  Guodong Liu,et al.  Aptamer-functionalized gold nanoparticles as probes in a dry-reagent strip biosensor for protein analysis. , 2009, Analytical chemistry.

[17]  J. Park,et al.  Disposable liposome immunosensor for theophylline combining an immunochromatographic membrane and a thick-film electrode , 1999 .

[18]  C. Heeschen,et al.  Evaluation of a rapid whole blood ELISA for quantification of troponin I in patients with acute chest pain. , 1999, Clinical chemistry.

[19]  Y. Kitaura,et al.  Development of a simple whole blood panel test for detection of human heart-type fatty acid-binding protein. , 2001, Clinical biochemistry.

[20]  E. F. Ullman,et al.  Enzyme immunochromatography--a quantitative immunoassay requiring no instrumentation. , 1985, Clinical chemistry.