Three-dimensional spiral CT during arterial portography: comparison of three rendering techniques.

The three most common techniques for three-dimensional reconstruction are surface rendering, maximum-intensity projection (MIP), and volume rendering. Surface-rendering algorithms model objects as collections of geometric primitives that are displayed with surface shading. The MIP algorithm renders an image by selecting the voxel with the maximum intensity signal along a line extended from the viewer's eye through the data volume. Volume-rendering algorithms sum the weighted contributions of all voxels along the line. Each technique has advantages and shortcomings that must be considered during selection of one for a specific clinical problem and during interpretation of the resulting images. With surface rendering, sharp-edged, clear three-dimensional reconstruction can be completed on modest computer systems; however, overlapping structures cannot be visualized and artifacts are a problem. MIP is computationally a fast technique, but it does not allow depiction of overlapping structures, and its images are three-dimensionally ambiguous unless depth cues are provided. Both surface rendering and MIP use less than 10% of the image data. In contrast, volume rendering uses nearly all of the data, allows demonstration of overlapping structures, and engenders few artifacts, but it requires substantially more computer power than the other techniques.

[1]  Alan Kalvin,et al.  Quantitative and Qualitative Comparison of Voluinetric and Surface Rendering Techniques , 1990 .

[2]  M W Vannier,et al.  Spiral CT: decreased spatial resolution in vivo due to broadening of section-sensitivity profile. , 1992, Radiology.

[3]  P. Soyer,et al.  Segmental anatomy of the liver: utility of a nomenclature accepted worldwide. , 1993, AJR. American journal of roentgenology.

[4]  S. Napel,et al.  Three-dimensional spiral CT angiography of the abdomen: initial clinical experience. , 1993, Radiology.

[5]  E K Fishman,et al.  Three-dimensional CT-volumetric reconstruction and display of the bronchial tree. , 1990, Investigative radiology.

[6]  M W Vannier,et al.  Craniosynostosis: diagnostic value of three-dimensional CT reconstruction. , 1989, Radiology.

[7]  R. A. Drebin,et al.  Fidelity of Three‐dimensional CT Imaging for Detecting Fracture Gaps , 1989, Journal of computer assisted tomography.

[8]  E. Fishman,et al.  Surgical segmental anatomy of the liver: demonstration with spiral CT during arterial portography and multiplanar reconstruction. , 1994, AJR. American journal of roentgenology.

[9]  M W Vannier,et al.  Three dimensional CT reconstruction images for craniofacial surgical planning and evaluation. , 1984, Radiology.

[10]  J. Remy,et al.  Angioarchitecture of pulmonary arteriovenous malformations: clinical utility of three-dimensional helical CT. , 1994, Radiology.

[11]  M Galanski,et al.  Renal arterial stenoses: spiral CT angiography. , 1993, Radiology.

[12]  D R Ney,et al.  Spiral Computed Tomography Arterial Portography With Three-Dimensional Volumetric Rendering for Oncologic Surgery Planning: A Retrospective Analysis , 1994, Investigative radiology.

[13]  G. Herman,et al.  Three-dimensional display of human organs from computed tomograms , 1979 .

[14]  Charles S. O'Mara,et al.  Spiral CT of renal artery stenosis: Comparison of three-dimensional rendering techniques: Rubin GD, Dake MD, Napel S, Jeffrey RB, McDonnell CH, Sommer FG, Wexler L, Williams DM. Radiology 1994;190:181-9 , 1994 .

[15]  A Roche,et al.  Preoperative segmental localization of hepatic metastases: utility of three-dimensional CT during arterial portography. , 1991, Radiology.

[16]  Andreas Pommert,et al.  Investigation of medical 3D-rendering algorithms , 1990, IEEE Computer Graphics and Applications.

[17]  G D Rubin,et al.  CT angiography with spiral CT and maximum intensity projection. , 1992, Radiology.

[18]  Arie E. Kaufman,et al.  Intermixing Surface and Volume Rendering , 1990 .

[19]  R H Hruban,et al.  Three-dimensional reconstruction of the human body. , 1988, AJR. American journal of roentgenology.

[20]  G Wang,et al.  Technical optimization of spiral CT for depiction of renal artery stenosis: in vitro analysis. , 1995, Radiology.

[21]  W. Kalender,et al.  Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. , 1990, Radiology.

[22]  Reiner Lenz,et al.  Evaluation of methods for shaded surface display of CT volumes. , 1991 .

[23]  M W Vannier,et al.  Surface imaging from computerized tomographic scans. , 1983, Surgery.

[24]  R. Bernstein,et al.  Shading 3D-Images from CT Using Gray-Level Gradients , 1986, IEEE Transactions on Medical Imaging.

[25]  Richard A. Baum,et al.  Magnetic Resonance Angiography: Concepts and Applications , 1995 .

[26]  M. Castillo,et al.  Diagnosis of disease of the common carotid artery bifurcation: CT angiography vs catheter angiography. , 1993, AJR. American journal of roentgenology.

[27]  D A Bluemke,et al.  Spiral CT of the liver. , 1993, AJR. American journal of roentgenology.

[28]  Pat Hanrahan,et al.  Volume Rendering , 2020, Definitions.

[29]  S Napel,et al.  Diagnosis of carotid artery disease: preliminary experience with maximum-intensity-projection spiral CT angiography. , 1993, AJR. American journal of roentgenology.

[30]  M W Vannier,et al.  Complex musculoskeletal anatomy: analysis using three dimensional surface reconstruction. , 1984, Radiology.

[31]  D Magid,et al.  Volumetric rendering techniques: applications for three-dimensional imaging of the hip. , 1987, Radiology.

[32]  M S van Leeuwen,et al.  CT angiography: application to the evaluation of carotid artery stenosis. , 1993, Radiology.

[33]  Elliot K. Fishman,et al.  Volumetric rendering of computed tomography data: principles and techniques , 1990, IEEE Computer Graphics and Applications.

[34]  D Magid,et al.  Advanced three-dimensional evaluation of acetabular trauma: volumetric image processing. , 1989, The Journal of trauma.

[35]  G. Wang,et al.  Stair-step artifacts in three-dimensional helical CT: an experimental study. , 1994, Radiology.