Three-dimensional spiral CT during arterial portography: comparison of three rendering techniques.
暂无分享,去创建一个
B S Kuszyk | D G Heath | D A Bluemke | M. Choti | E. Fishman | D. Bluemke | D. Heath | B. Kuszyk | P. Soyer | P. Calhoun | D. F. Bliss | P A Soyer | D F Bliss | P S Calhoun | M A Choti | E K Fishman | P. S. Calhoun
[1] Alan Kalvin,et al. Quantitative and Qualitative Comparison of Voluinetric and Surface Rendering Techniques , 1990 .
[2] M W Vannier,et al. Spiral CT: decreased spatial resolution in vivo due to broadening of section-sensitivity profile. , 1992, Radiology.
[3] P. Soyer,et al. Segmental anatomy of the liver: utility of a nomenclature accepted worldwide. , 1993, AJR. American journal of roentgenology.
[4] S. Napel,et al. Three-dimensional spiral CT angiography of the abdomen: initial clinical experience. , 1993, Radiology.
[5] E K Fishman,et al. Three-dimensional CT-volumetric reconstruction and display of the bronchial tree. , 1990, Investigative radiology.
[6] M W Vannier,et al. Craniosynostosis: diagnostic value of three-dimensional CT reconstruction. , 1989, Radiology.
[7] R. A. Drebin,et al. Fidelity of Three‐dimensional CT Imaging for Detecting Fracture Gaps , 1989, Journal of computer assisted tomography.
[8] E. Fishman,et al. Surgical segmental anatomy of the liver: demonstration with spiral CT during arterial portography and multiplanar reconstruction. , 1994, AJR. American journal of roentgenology.
[9] M W Vannier,et al. Three dimensional CT reconstruction images for craniofacial surgical planning and evaluation. , 1984, Radiology.
[10] J. Remy,et al. Angioarchitecture of pulmonary arteriovenous malformations: clinical utility of three-dimensional helical CT. , 1994, Radiology.
[11] M Galanski,et al. Renal arterial stenoses: spiral CT angiography. , 1993, Radiology.
[12] D R Ney,et al. Spiral Computed Tomography Arterial Portography With Three-Dimensional Volumetric Rendering for Oncologic Surgery Planning: A Retrospective Analysis , 1994, Investigative radiology.
[13] G. Herman,et al. Three-dimensional display of human organs from computed tomograms , 1979 .
[14] Charles S. O'Mara,et al. Spiral CT of renal artery stenosis: Comparison of three-dimensional rendering techniques: Rubin GD, Dake MD, Napel S, Jeffrey RB, McDonnell CH, Sommer FG, Wexler L, Williams DM. Radiology 1994;190:181-9 , 1994 .
[15] A Roche,et al. Preoperative segmental localization of hepatic metastases: utility of three-dimensional CT during arterial portography. , 1991, Radiology.
[16] Andreas Pommert,et al. Investigation of medical 3D-rendering algorithms , 1990, IEEE Computer Graphics and Applications.
[17] G D Rubin,et al. CT angiography with spiral CT and maximum intensity projection. , 1992, Radiology.
[18] Arie E. Kaufman,et al. Intermixing Surface and Volume Rendering , 1990 .
[19] R H Hruban,et al. Three-dimensional reconstruction of the human body. , 1988, AJR. American journal of roentgenology.
[20] G Wang,et al. Technical optimization of spiral CT for depiction of renal artery stenosis: in vitro analysis. , 1995, Radiology.
[21] W. Kalender,et al. Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. , 1990, Radiology.
[22] Reiner Lenz,et al. Evaluation of methods for shaded surface display of CT volumes. , 1991 .
[23] M W Vannier,et al. Surface imaging from computerized tomographic scans. , 1983, Surgery.
[24] R. Bernstein,et al. Shading 3D-Images from CT Using Gray-Level Gradients , 1986, IEEE Transactions on Medical Imaging.
[25] Richard A. Baum,et al. Magnetic Resonance Angiography: Concepts and Applications , 1995 .
[26] M. Castillo,et al. Diagnosis of disease of the common carotid artery bifurcation: CT angiography vs catheter angiography. , 1993, AJR. American journal of roentgenology.
[27] D A Bluemke,et al. Spiral CT of the liver. , 1993, AJR. American journal of roentgenology.
[28] Pat Hanrahan,et al. Volume Rendering , 2020, Definitions.
[29] S Napel,et al. Diagnosis of carotid artery disease: preliminary experience with maximum-intensity-projection spiral CT angiography. , 1993, AJR. American journal of roentgenology.
[30] M W Vannier,et al. Complex musculoskeletal anatomy: analysis using three dimensional surface reconstruction. , 1984, Radiology.
[31] D Magid,et al. Volumetric rendering techniques: applications for three-dimensional imaging of the hip. , 1987, Radiology.
[32] M S van Leeuwen,et al. CT angiography: application to the evaluation of carotid artery stenosis. , 1993, Radiology.
[33] Elliot K. Fishman,et al. Volumetric rendering of computed tomography data: principles and techniques , 1990, IEEE Computer Graphics and Applications.
[34] D Magid,et al. Advanced three-dimensional evaluation of acetabular trauma: volumetric image processing. , 1989, The Journal of trauma.
[35] G. Wang,et al. Stair-step artifacts in three-dimensional helical CT: an experimental study. , 1994, Radiology.