Micro-CT as a guide for clinical CT development

Micro-CT, with voxel size ~10-5 mm3, has a great advantage over traditional microscopic methods in its ability to generate detailed 3D images in relatively large, opaque, volumes such as an intact mouse femur, heart or kidney. In addition to providing new insights into tissue structure-to-function interrelationships, micro-CT can contribute to suggesting new applications of clinical CT imaging such as: A. The spatio-density-temporal resolution that is needed to: 1) Quantitate an organ's Basic Functional Unit (smallest collection of diverse cells that behaves like the organ), which requires voxels less than 10-4 mm3 in volume; 2) Quantitate new vessel growth which manifests as increased x-ray contrast enhancement in tissues during passage of a bolus of intravascular contrast agent; 3) Quantitate endothelial integrity by the movement of x-ray contrast agents across the endothelial inner lining of vessel walls. B. The use of x-ray scatter for providing the contrast amongst soft tissue components and/or their interfaces for enhanced discrimination of nerve and muscular/tendon fiber directions.

[1]  E. Ritman Myocardial Capillary Permeability to Iohexol: Evaluation with Fast X-Ray Computed Tomography , 1994, Investigative radiology.

[2]  E L Ritman,et al.  LV pressure-volume area and oxygen consumption: evaluation in intact dog by fast CT. , 1990, The American journal of physiology.

[3]  Erik L Ritman,et al.  Correlation of Vasa Vasorum Neovascularization and Plaque Progression in Aortas of Apolipoprotein E−/−/Low-Density Lipoprotein−/− Double Knockout Mice , 2005, Arteriosclerosis, thrombosis, and vascular biology.

[4]  E. Ritman,et al.  Vasa vasorum growth in the coronary arteries of newborn pigs , 2004, Anatomy and Embryology.

[5]  Erik L. Ritman,et al.  Branching Morphology of the Rat Hepatic Portal Vein Tree: A Micro-CT Study , 2006, Annals of Biomedical Engineering.

[6]  M. Poletti,et al.  X-ray scattering from human breast tissues and breast-equivalent materials. , 2002, Physics in medicine and biology.

[7]  S M Jorgensen,et al.  Three-dimensional imaging of vasculature and parenchyma in intact rodent organs with X-ray micro-CT. , 1998, The American journal of physiology.

[8]  K. Stierstorfer,et al.  First performance evaluation of a dual-source CT (DSCT) system , 2006, European Radiology.

[9]  E. Ritman,et al.  Cryostatic micro-computed tomography imaging of arterial wall perfusion. , 2002, Scanning.

[10]  A Fenster,et al.  Tomographic imaging of the angular-dependent coherent-scatter cross section. , 1997, Medical physics.

[11]  Carolyn A. MacDonald,et al.  Micro-CT scanner with a focusing polycapillary x-ray optic , 1999, Optics & Photonics.

[12]  W.E. Higgins,et al.  System for analyzing high-resolution three-dimensional coronary angiograms , 1996, IEEE Trans. Medical Imaging.

[13]  Suzanne T. Witt,et al.  Point spread function deconvolution in 3D micro-CT angiography for multiscale vascular tree separation , 2003, SPIE Medical Imaging.