Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET

Respiratory motion is a source of artefacts and quantification errors in cardiac imaging. Preliminary studies with retrospective respiratory gating in PET support the observation of other imaging modalities of a rigid-body motion of the heart during respiration. However, the use of gating techniques to eliminate motion may result in poor count statistics per reconstructed image. We have implemented a motion correction technique which applies rigid-body transformations on list-mode data event-by-event on the basis of a geometric model of intersection of the lines-of-response with the scanner. Pre-correction for detector efficiencies and photon attenuation before transformation are included in the process. Projection data are acquired together with physiological signal (every ms) from an inductive respiration monitor with an elasticised belt at chest level. Data are retrospectively sorted into separate respiratory gates on an off-line workstation. Transformation parameters relating the gated images, estimated by means of image registration, can be applied on the original list-mode data to obtain a single motion-corrected dataset. The accuracy of the technique was assessed with point source data and a good correlation between applied and measured transformations, estimated from the centroid of the source, was observed. The technique was applied on phantom data with simulated respiratory motion and on patient data with C/sup 15/O and /sup 18/FDG. Quantitative assessment of preliminary C/sup 15/O patient datasets showed at least 4.5% improvement in the recovery coefficient at the centre of the left ventricle.

[1]  David Atkinson,et al.  A study of the motion and deformation of the heart due to respiration , 2002, IEEE Transactions on Medical Imaging.

[2]  M. S. Atkins,et al.  Compensation methods for head motion detected during PET imaging , 1996 .

[3]  Guang-Zhong Yang,et al.  Predictive cardiac motion modeling and correction with partial least squares regression , 2004, IEEE Transactions on Medical Imaging.

[4]  D L Bailey,et al.  Experience with fully 3D PET and implications for future high-resolution 3D tomographs. , 1998, Physics in medicine and biology.

[5]  C. Ling,et al.  Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer. , 2002, Medical physics.

[6]  G. J. Klein,et al.  Real-time system for respiratory-cardiac gating in positron tomography , 1997 .

[7]  Torsten Kuwert,et al.  Three-dimensional contour detection of left ventricular myocardium using elastic surfaces , 1999, European Journal of Nuclear Medicine.

[8]  P. Cutler,et al.  Local threshold for segmented attenuation correction of PET imaging of the thorax , 1993 .

[9]  A. Rahmim,et al.  Motion compensation in histogram-mode and list-mode EM reconstructions: beyond the event-driven approach , 2004, IEEE Transactions on Nuclear Science.

[10]  M E Phelps,et al.  Electrocardiographic gating in positron emission computed tomography. , 1979, Journal of computer assisted tomography.

[11]  Cyrill Burger,et al.  PET-CT image co-registration in the thorax: influence of respiration , 2002, European Journal of Nuclear Medicine and Molecular Imaging.

[12]  Colin Studholme,et al.  An overlap invariant entropy measure of 3D medical image alignment , 1999, Pattern Recognit..

[13]  Roger Fulton,et al.  The design and implementation of a motion correction scheme for neurological PET. , 2003, Physics in medicine and biology.

[14]  Ornella Rimoldi,et al.  Cardiac and respiratory gating of list-mode data on a high sensitivity PET scanner, the ECAT EXACT3D , 1999 .

[15]  B E Sobel,et al.  Influence of Cardiac and Respiratory Motion on Tomographic Reconstructions of the Heart: Implications for Quantitative Nuclear Cardiology , 1982, Journal of computer assisted tomography.

[16]  Lars Stegger,et al.  Elastic surface contour detection for the measurement of ejection fraction in myocardial perfusion SPET , 2001, European Journal of Nuclear Medicine.

[17]  T. Spinks,et al.  Physical characteristics of the ECAT EXACT3D positron tomograph. , 2000, Physics in medicine and biology.

[18]  P Richards,et al.  Effect of respiratory motion on pulmonary activity determinations by positron tomography in dogs. , 1985, Investigative radiology.

[19]  R C Grimm,et al.  Respiratory kinematics of the upper abdominal organs: A quantitative study , 1992, Magnetic resonance in medicine.

[20]  J Keegan,et al.  MR navigator‐echo monitoring of temporal changes in diaphragm position: Implications for MR coronary angiography , 1997, Journal of magnetic resonance imaging : JMRI.