DC fault isolation study of bidirectional dual active bridge DC/DC converter for DC transmission grid application

Fast isolation and detection of DC faults is currently a limiting factor in high power DC transmission grid development. Recent research has shown that the role of DC/DC converters is becoming increasingly important in solving various DC grid challenges such as voltage stepping, galvanic isolation and power regulation. This paper focuses on an additional important feature of bidirectional dual active bridge (DAB) DC-DC converters which make it attractive for future DC grids; it's inherent fault isolation capability which does not need control intervention to limit fault current in case of the most severe DC faults. Detailed analytical, simulation and experimental study are performed by subjecting the converter to DC short circuit faults at its DC voltage terminals. The results obtained have shown significant advantage of DAB where fault current is less than rated current during the fault duration. Thus no control action is necessary from the non-faulted bridge to limit fault current and no external DC circuit breakers are required. This advantage makes DAB converter feasible for DC grid integration.

[1]  Dragan Jovcic,et al.  Evaluation of Semiconductor Based Methods for Fault Isolation on High Voltage DC Grids , 2013, IEEE Transactions on Smart Grid.

[2]  S. J. Finney,et al.  New Breed of Network Fault-Tolerant Voltage-Source-Converter HVDC Transmission System , 2013, IEEE Transactions on Power Systems.

[3]  Grain Philip Adam,et al.  Comprehensive steady state analysis of bidirectional dual active bridge DC/DC converter using triple phase shift control , 2014, 2014 IEEE 23rd International Symposium on Industrial Electronics (ISIE).

[4]  R.W. De Doncker,et al.  Circuit breaker concepts for future high-power DC-applications , 2005, Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005..

[5]  Li Ran,et al.  Harmonic analysis and improvement of a new solid-state fault current limiter , 2004, IEEE Transactions on Industry Applications.

[6]  Barry W. Williams,et al.  New emerging voltage source converter for high-voltage application: hybrid multilevel converter with dc side H-bridge chain links , 2014 .

[7]  D. Jovcic Bidirectional, High-Power DC Transformer , 2009, IEEE Transactions on Power Delivery.

[8]  L. Salasoo,et al.  Comparison of superconducting fault limiter concepts in electric utility applications , 1995, IEEE Transactions on Applied Superconductivity.

[9]  P. Manohar,et al.  DC line protection for VSC-HVDC system , 2012, 2012 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES).

[10]  G. Mauthe,et al.  Development of a high current HVDC circuit breaker with fast fault clearing capability , 1988 .

[11]  John E. Fletcher,et al.  Hybrid Cascaded Modular Multilevel Converter With DC Fault Ride-Through Capability for the HVDC Transmission System , 2015, IEEE Transactions on Power Delivery.

[12]  D.M. Divan,et al.  A three-phase soft-switched high power density DC/DC converter for high power applications , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[13]  Dirk Van Hertem,et al.  Feasibility of DC transmission networks , 2011, 2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies.

[14]  D. Jovcic,et al.  High power IGBT-based DC/DC converter with DC fault tolerance , 2012, 2012 15th International Power Electronics and Motion Control Conference (EPE/PEMC).

[15]  Derrick Holliday,et al.  Quasi Two-Level Operation of Modular Multilevel Converter for Use in a High-Power DC Transformer With DC Fault Isolation Capability , 2015, IEEE Transactions on Power Electronics.