UNBALANCED LOADING; AN OVERLOOKED CONTRIBUTOR TO POWER LOSSES IN HESCO

Energy losses are hampering progress of the developing countries like Pakistan by putting extra financial burden that could have been used for development projects of the power sector. Electricity consumers are paying high energy cost despite of facing long duration load shedding and frequent small duration supply interruptions. Although electricity theft is considered as major cause of the losses but technical losses caused by aged distribution network and poor operation planning is also on higher side. Unbalanced loading caused by single phase loads supplied by three phase four wire system is an ignored source of power loss in distribution utilities of Pakistan, which is controllable by small investment on monitoring and line staff dedicated for load balancing. In this paper, one of the distribution feeder in Hyderabad is selected for analysis of power losses caused by unbalanced loading. Exact data collection, modelling and simulation of the selected feeder shows high load unbalance. Balancing of the observed unbalanced loads result in power loss reduction of 62.8 kW amounting to an annual savings of Rs. 2.68 Million. It is recommended to HESCO and other distribution utilities in Pakistan to depute dedicated line staff for monitoring and balancing of the transformer loads to increase energy efficiency. Smart meter installation at all transformers will provide unbalance data for pre-set time intervals for balance analysis.

[1]  Chao-Shun Chen,et al.  An Expert System for Three-Phase Balancing of Distribution Feeders , 2008, IEEE Transactions on Power Systems.

[2]  G. Yesuratnam,et al.  Impact of voltage and power factor change on primary distribution feeder power loss in radial and loop type of feeders , 2012, 2012 International Conference on Emerging Trends in Electrical Engineering and Energy Management (ICETEEEM).

[3]  S. Deb,et al.  Performance optimisation of radial power distribution networks-A desegregated approach , 2012, IEEE-International Conference On Advances In Engineering, Science And Management (ICAESM -2012).

[4]  Masoud Ghiafeh Davoudi,et al.  Effects of unsymmetrical power transmission system on the voltage balance and power flow capacity of the lines , 2012, 2012 11th International Conference on Environment and Electrical Engineering.

[5]  R. M. Ciric,et al.  Power flow in four-wire distribution networks-general approach , 2003 .

[6]  Agha Zafarullah Pathan,et al.  Critical analysis of capacitors as a potential solution to achieve optimum level voltage regulation in HESCO network , 2013, 2013 The International Conference on Technological Advances in Electrical, Electronics and Computer Engineering (TAEECE).

[7]  Irfan Ahmed Halepoto,et al.  Impact of distributed generation on network short circuit level , 2014, 2014 4th International Conference on Wireless Communications, Vehicular Technology, Information Theory and Aerospace & Electronic Systems (VITAE).

[8]  Julio Romero Aguero Improving the efficiency of power distribution systems through technical and non-technical losses reduction , 2012, T&D 2012.