High energy pipe break analysis for a Main Steam Line of a WWER NPP
暂无分享,去创建一个
Abstract The aim of this study is to show the application of the High Energy Pipe Break (HEPB) methodology to a level 3 analysis, applied to the study of the Main Steam Line (MSL) of a Mochovce (MO) NPP. The analysis highlighted the significant advantage, as compared to a standard level 1 analysis, in the minimization of extra supports and restraints. In the first part of the paper an introduction on the NUREG Standard Review Plan (STRP) and on the ANSI/ANS 58.2 used as a reference in this kind of analysis is provided. In the second part a description of the analyses (coupled mechanical and fluido-dynamic) used to analyze the HEPB is described. Finally an original approach developed at ENEL is presented for an improved evaluation of the leakage cracking by following a non standard procedure related to the LBB approach, coupled with the above-mentioned HEPB.
[1] A Andersen,et al. Protection against high-energy line breaks in WWER power plants , 2001 .