Precision wearable accelerometer contact microphones for longitudinal monitoring of mechano-acoustic cardiopulmonary signals

Mechano-acoustic signals emanating from the heart and lungs contain valuable information about the cardiopulmonary system. Unobtrusive wearable sensors capable of monitoring these signals longitudinally can detect early pathological signatures and titrate care accordingly. Here, we present a wearable, hermetically-sealed high-precision vibration sensor that combines the characteristics of an accelerometer and a contact microphone to acquire wideband mechano-acoustic physiological signals, and enable simultaneous monitoring of multiple health factors associated with the cardiopulmonary system including heart and respiratory rate, heart sounds, lung sounds, and body motion and position of an individual. The encapsulated accelerometer contact microphone (ACM) utilizes nano-gap transducers to achieve extraordinary sensitivity in a wide bandwidth (DC-12 kHz) with high dynamic range. The sensors were used to obtain health factors of six control subjects with varying body mass index, and their feasibility in detection of weak mechano-acoustic signals such as pathological heart sounds and shallow breathing patterns is evaluated on patients with preexisting conditions.

[1]  P. Ongley,et al.  The Clinical Value of Phonocardiography , 1954, Circulation.

[2]  J. L. Beck,et al.  Cardiac auscultation. , 1977, The Journal of the American Osteopathic Association.

[3]  R. Briggs,et al.  Raised respiratory rate in elderly patients: a valuable physical sign. , 1982, British medical journal.

[4]  G. Gibson,et al.  Abnormalities of chest wall motion in patients with chronic airflow obstruction. , 1984, Thorax.

[5]  M. Tavel,et al.  Spectral analysis of heart sounds: relationships between some physical characteristics and frequency spectra of first and second heart sounds in normals and hypertensives. , 1984, Journal of biomedical engineering.

[6]  P. Sobotka,et al.  Implications of an audible third heart sound in evaluating cardiac function. , 1993, The Western journal of medicine.

[7]  R A Wilson,et al.  Diagnostic accuracy of seismocardiography compared with electrocardiography for the anatomic and physiologic diagnosis of coronary artery disease during exercise testing. , 1993, The American journal of cardiology.

[8]  J A Shaver,et al.  Cardiac auscultation: a cost-effective diagnostic skill. , 1995, Current problems in cardiology.

[9]  K M McConnochie,et al.  Predicting Deterioration in Previously Healthy Infants Hospitalized With Respiratory Syncytial Virus Infection , 1999, Pediatrics.

[10]  M. Drazner,et al.  Prognostic importance of elevated jugular venous pressure and a third heart sound in patients with heart failure. , 2001, The New England journal of medicine.

[11]  Daniel Levy,et al.  The Epidemiology of Asymptomatic Left Ventricular Systolic Dysfunction: Implications for Screening , 2003, Annals of Internal Medicine.

[12]  I. Khan,et al.  Third heart sound: genesis and clinical importance. , 2004, International journal of cardiology.

[13]  Z. Moussavi,et al.  Heart Sounds Separation From Lung Sounds Using Independent Component Analysis , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[14]  Tiago H. Falk,et al.  Modulation filtering for heart and lung sound separation from breath sound recordings , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[15]  E. Andrès,et al.  Analysis of Respiratory Sounds: State of the Art , 2008, Clinical medicine. Circulatory, respiratory and pulmonary medicine.

[16]  O. Postolache,et al.  Theory and Developments in an Unobtrusive Cardiovascular System Representation: Ballistocardiography , 2010, The open biomedical engineering journal.

[17]  Peter P. Liu,et al.  Early detection of myocardial dysfunction and heart failure , 2010, Nature Reviews Cardiology.

[18]  Yan-Wei Guo,et al.  Estimation of respiration rate from three-dimensional acceleration data based on body sensor network. , 2011, Telemedicine journal and e-health : the official journal of the American Telemedicine Association.

[19]  Eloi Marijon,et al.  State-of-the-art Paper Prevalences, Patterns, and the Potential of Early Disease Detection , 2022 .

[20]  Keya Pandia,et al.  Extracting respiratory information from seismocardiogram signals acquired on the chest using a miniature accelerometer , 2012, Physiological measurement.

[21]  Pramodsingh H Thakur,et al.  Feasibility of Heart Sounds Measurements from an Accelerometer within an ICD Pulse Generator , 2013, Pacing and clinical electrophysiology : PACE.

[22]  James H. McClellan,et al.  Seismocardiography-based detection of cardiac quiescence for cardiac computed tomography angiography , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[23]  A. Bohadana,et al.  Fundamentals of lung auscultation. , 2014, The New England journal of medicine.

[24]  M. Sarkar,et al.  Auscultation of the respiratory system , 2015, Annals of thoracic medicine.

[25]  Eric J. Topol,et al.  The emerging field of mobile health , 2015, Science Translational Medicine.

[26]  Theodore P Abraham,et al.  Pacemaker-induced transient asynchrony suppresses heart failure progression , 2015, Science Translational Medicine.

[27]  James J S Norton,et al.  Epidermal mechano-acoustic sensing electronics for cardiovascular diagnostics and human-machine interfaces , 2016, Science Advances.

[28]  Russell T. Baker,et al.  A CLINICAL GUIDE TO THE ASSESSMENT AND TREATMENT OF BREATHING PATTERN DISORDERS IN THE PHYSICALLY ACTIVE: PART 2, A CASE SERIES. , 2016, International journal of sports physical therapy.

[29]  G. Fonarow,et al.  Epidemiology and aetiology of heart failure , 2016, Nature Reviews Cardiology.

[30]  Shannon M. Dunlay,et al.  Epidemiology of heart failure with preserved ejection fraction , 2017, Nature Reviews Cardiology.

[31]  J. Butler,et al.  Heart failure with reduced ejection fraction , 2017, Nature Reviews Disease Primers.

[32]  Shuvo Roy,et al.  Quantifying and Reducing Motion Artifacts in Wearable Seismocardiogram Measurements During Walking to Assess Left Ventricular Health , 2017, IEEE Transactions on Biomedical Engineering.

[33]  Farrokh Ayazi,et al.  Low-Pressure Wafer-Level-Packaged Capacitive Accelerometers With High Dynamic Range and Wide Bandwidth Using Nano-Gap Sloped Electrode Design , 2017, Journal of Microelectromechanical Systems.

[34]  Gianluigi Savarese,et al.  Global Public Health Burden of Heart Failure. , 2016, Cardiac failure review.

[35]  Jessilyn Dunn,et al.  Wearables and the medical revolution. , 2018, Personalized medicine.

[36]  S. Steinhubl,et al.  Effect of a Home-Based Wearable Continuous ECG Monitoring Patch on Detection of Undiagnosed Atrial Fibrillation: The mSToPS Randomized Clinical Trial , 2018, JAMA.

[37]  J. Pevnick,et al.  Wearable technology for cardiology: An update and framework for the future. , 2018, Trends in cardiovascular medicine.

[38]  A. O. Bicen,et al.  Novel Wearable Seismocardiography and Machine Learning Algorithms Can Assess Clinical Status of Heart Failure Patients , 2018, Circulation. Heart failure.

[39]  Farrokh Ayazi,et al.  Wafer-level-packaged HARPSS+ MEMS platform: Integration of robust timing and inertial measurement units (TIMU) on a single chip , 2018, 2018 IEEE/ION Position, Location and Navigation Symposium (PLANS).

[40]  Anna Tampieri,et al.  Inhalation of peptide-loaded nanoparticles improves heart failure , 2018, Science Translational Medicine.

[41]  Farrokh Ayazi,et al.  PRECISION HIGH-BANDWIDTH OUT-OF-PLANE ACCELEROMETER AS CONTACT MICROPHONE FOR BODY-WORN AUSCULTATION DEVICES , 2018 .

[42]  Jayoung Kim,et al.  Wearable biosensors for healthcare monitoring , 2019, Nature Biotechnology.

[43]  Ramesh Jain,et al.  Respiration rate and volume measurements using wearable strain sensors , 2019, npj Digital Medicine.

[44]  Amirtaha Taebi,et al.  Recent Advances in Seismocardiography , 2019, Vibration.