Emissions of ammonia and greenhouse gases from naturally ventilated livestock houses cause contamination of the surrounding atmospheric environment. Requests to reduce ammonia emissions from livestock farms are growing in Denmark. It is assumed that using an additional mechanical pit exhaust unit with a minimised ventilation rate can remove the most polluted part of the air from the slurry pit and treat it with an air purification unit. This system can result in reduction of ammonia emissions from naturally ventilated livestock production units. To study the efficiency of a partial pit ventilation to reduce emissions, a 1:2 scale model of manure pit section of a dairy cattle house was built with slatted floor and a mechanical pit exhaust at side-walls. Investigations were performed under varied airflow velocities above the floor, two slatted floor opening ratios (the ratio of the opening area to the whole floor area), two pit ventilation rates and two exhaust directions. CO"2 was used as tracer gas and was added to the mixing chamber of the pit model with a constant flux. The removal ratio was defined as the percentage of the gases removed by the pit exhaust. The results showed that a partial pit exhaust system could abate gas emissions from the slurry pit. The performance of the system was influenced by the following factors: airflow velocities above the floor, the slatted floor opening ratio, the pit ventilation rates and the pit exhaust position. For downwind exhaust, the removal ratios were decreased from about 80% to 50% when the air velocity above the floor was increased from 0.78 to 1.94ms^-^1. The mean of the removal ratios was 83.1% for all upwind exhaust cases and some downwind exhaust cases. There was no clear velocity dependency. Lower floor opening ratio could reduce more emission than the higher opening ratio for most of the cases. Higher pit ventilation rates resulted in higher removal ratios for most cases of downwind exhaust but did not always give higher removing efficiency for upwind exhaust. Overall, the upwind exhaust can discharge 8% more CO"2 than the downwind exhaust. Removal capability was better correlated to the four factors (airflow velocities above the floor, the slatted floor opening ratio, the pit ventilation rates and the pit exhaust position) combined when compared to the correlation to each individual factor. The results from the scale model measurements need to be validated by full-scale experiments.
[1]
Guoqiang Zhang,et al.
Modeling Jet Drop Distances for Control of a Nonisothermal, Flap-adjusted Ventilation Jet
,
1996
.
[2]
Guoqiang Zhang,et al.
Emission effects of three different ventilation control strategies—A scale model study
,
2008
.
[3]
D. Olivari,et al.
Numerical and experimental modelling of pollutant dispersion in a street canyon
,
2002
.
[4]
Chun-Ho Liu,et al.
Large-Eddy Simulation of Flow and Scalar Transport in a Modeled Street Canyon
,
2002
.
[5]
Guoqiang Zhang,et al.
Assessing effect of wind tunnel sizes on air velocity and concentration boundary layers and on ammonia emission estimation using computational fluid dynamics (CFD)
,
2011
.
[6]
Jan Willem Erisman,et al.
Ammonia emission from dairy cow buildings: a review of measurement techniques, influencing factors and possibilities for reduction
,
1998
.
[7]
Baoming Li,et al.
Emission of Ammonia and Other Contaminant Gases from Naturally Ventilated Dairy Cattle Buildings
,
2005
.
[8]
Guoqiang Zhang,et al.
Effects of a partial pit ventilation system on indoor air quality and ammonia emission from a fattening pig room
,
2010
.
[9]
Robert N. Meroney,et al.
Concentration and flow distributions in urban street canyons: wind tunnel and computational data
,
2003
.
[10]
G. T. Johnson,et al.
Urban wind flows: wind tunnel and numerical simulations—a preliminary comparison
,
1998
.