A Review on Noninvasive Beat-to-Beat Systemic and Pulmonary Blood Pressure Estimation Through Surrogate Cardiovascular Signals

Blood pressure monitoring is essential in hospital and home monitoring scenarios, with applications requiring on-line beat-to-beat blood pressure estimation, such as tele-monitoring of neurally mediated syncope. This chapter presents a comprehensive review of investigated approaches and reported performance, using different noninvasive correlates of the circulatory and cardiovascular system. Papers of interest were located in Scopus, IEEE Xplore and PubMed databases. The resulting pool of papers was then methodologically reviewed using 5 thematic taxonomies developed: 1) pulse arrival time and pulse transit time, 2) vascular transit time, 3) RS2 time, 4) heart sound characteristics, 5) PPG characteristics. The status of evidence in the literature demonstrates that cardiovascular signals such as the electrocardiogram, photoplethysmogram, and phonocardiogram contain important information for the estimation of blood pressure. Still, there are open issues regarding the validity, reliability and stability of these methods. A Review on Noninvasive Beat-to-Beat Systemic and Pulmonary Blood Pressure Estimation through Surrogate Cardiovascular Signals

[1]  Damijan Miklavcic,et al.  Modeling of electric field distribution in tissues during electroporation , 2013, Biomedical engineering online.

[2]  X. Aubert,et al.  Is pulse transit time a good indicator of blood pressure changes during short physical exercise in a young population? , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[3]  Enric Monte-Moreno,et al.  Non-invasive estimate of blood glucose and blood pressure from a photoplethysmograph by means of machine learning techniques , 2011, Artif. Intell. Medicine.

[4]  J. Naschitz,et al.  Pulse Transit Time by R-Wave-Gated Infrared Photoplethysmography: Review of the Literature and Personal Experience , 2004, Journal of Clinical Monitoring and Computing.

[5]  P. Castro,et al.  [Heart auscultatory assessment of pulmonary artery systolic pressure]. , 2010, Revista medica de Chile.

[6]  Conor Heneghan,et al.  Towards Using Photo-Plethysmogram Amplitude to Measure Blood Pressure During Sleep , 2010, Annals of Biomedical Engineering.

[7]  Koji Oguri,et al.  Cuffless blood pressure estimation by error-correcting output coding method based on an aggregation of AdaBoost with a photoplethysmograph sensor , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[8]  J. Foo,et al.  Pulse transit time in paediatric respiratory sleep studies. , 2007, Medical engineering & physics.

[9]  Daniel W. Jones,et al.  Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. , 2005, Hypertension.

[10]  A. Patzak,et al.  Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method , 2011, European Journal of Applied Physiology.

[11]  J. Foo,et al.  Pulse transit time as a derived noninvasive mean to monitor arterial distensibility changes in children , 2005, Journal of Human Hypertension.

[12]  T. Togawa,et al.  Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration , 2000, Medical and Biological Engineering and Computing.

[13]  X. Aubert,et al.  Cuffless Estimation of Systolic Blood Pressure for Short Effort Bicycle Tests: The Prominent Role of the Pre-Ejection Period , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[14]  L. Durand,et al.  Estimation of pulmonary artery pressure by spectral analysis of the second heart sound. , 1996, The American journal of cardiology.

[15]  Aniruddha Sinha,et al.  Estimation of blood pressure levels from reflective Photoplethysmograph using smart phones , 2013, 13th IEEE International Conference on BioInformatics and BioEngineering.

[16]  A Bartels,et al.  Non-invasive determination of systolic blood pressure by heart sound pattern analysis. , 1992, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[17]  L. Durand,et al.  A new, simple, and accurate method for non-invasive estimation of pulmonary arterial pressure , 2002, Heart.

[18]  X. Zhang,et al.  The Cuffless Arterial Blood Pressure Estimation based on the Timing- Characteristics of Second Heart Sound , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[19]  Gordon R. Williams,et al.  Pulse transit time changes observed with different limb positions , 2005, Physiological measurement.

[20]  G. Drummond,et al.  Assessment of pulse transit time to indicate cardiovascular changes during obstetric spinal anaesthesia. , 2006, British journal of anaesthesia.

[21]  Thomas F Budinger,et al.  Biomonitoring with wireless communications. , 2003, Annual review of biomedical engineering.

[22]  David B. Newlin,et al.  Relationships ol Pulse Transmission Times to Pre-ejection Period and Blood Pressure , 1981 .

[23]  Domenico Grimaldi,et al.  A Neural Network-based method for continuous blood pressure estimation from a PPG signal , 2013, 2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[24]  A A Adgey,et al.  The transthoracic impedance cardiogram is a potential haemodynamic sensor for an automated external defibrillator. , 1998, European heart journal.

[25]  Dan Ventura,et al.  A general model for continuous noninvasive pulmonary artery pressure estimation , 2013, Comput. Biol. Medicine.

[26]  J. Cohn,et al.  Noninvasive pulse wave analysis for the early detection of vascular disease. , 1995, Hypertension.

[27]  R. Payne,et al.  Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure. , 2006, Journal of applied physiology.

[28]  A. Hill,et al.  The Velocity of the Pulse Wave in Man , 1922 .

[29]  Carmen C. Y. Poon,et al.  Attenuation of Systolic Blood Pressure and Pulse Transit Time Hysteresis During Exercise and Recovery in Cardiovascular Patients , 2014, IEEE Transactions on Biomedical Engineering.

[30]  Carmen C. Y. Poon,et al.  An Evaluation of the Cuffless Blood Pressure Estimation Based on Pulse Transit Time Technique: a Half Year Study on Normotensive Subjects , 2009, Cardiovascular engineering.

[31]  Pulse transit time ratio as a potential marker for paediatric crural and brachial blood pressure index , 2007, Journal of Human Hypertension.

[32]  O. Chételat,et al.  Parametric estimation of pulse arrival time: a robust approach to pulse wave velocity , 2009, Physiological measurement.

[33]  Haruki Kawanaka,et al.  Cuffless blood pressure estimation using only photoplethysmography based on cardiovascular parameters , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[34]  Gian Domenico Pinna,et al.  Baroreflex Sensitivity: Measurement and Clinical Implications , 2008, Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc.

[35]  J. Foo,et al.  Predictive regression equations and clinical uses of peripheral pulse timing characteristics in children , 2005, Physiological measurement.

[36]  Satomi Suzuki,et al.  Cuffless and non-invasive Systolic Blood Pressure estimation for aged class by using a Photoplethysmograph , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[37]  M. Higginbotham,et al.  Relation between central and peripheral hemodynamics during exercise in patients with chronic heart failure. Muscle blood flow is reduced with maintenance of arterial perfusion pressure. , 1989, Circulation.

[38]  L. Senhadji,et al.  Estimation of pulmonary arterial pressure by a neural network analysis using features based on time-frequency representations of the second heart sound , 2002, Medical and Biological Engineering and Computing.

[39]  M. Tavel,et al.  Cardiac Auscultation: A Glorious Past—And It Does Have a Future! , 2006, Circulation.

[40]  J. Ottesen,et al.  Describing the pumping heart as a pressure source. , 2001, Journal of theoretical biology.

[41]  Yutaka Imai,et al.  Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults , 2002, Blood pressure monitoring.

[42]  Régis Logier,et al.  Heart rate variability analysis for arterial hypertension etiological diagnosis during surgical procedures under tourniquet , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[43]  Carmen C. Y. Poon,et al.  Cuff-less and Noninvasive Measurements of Arterial Blood Pressure by Pulse Transit Time , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[44]  V. C. Padaki,et al.  Smart Vest: wearable multi-parameter remote physiological monitoring system. , 2008, Medical engineering & physics.

[45]  J. Muehlsteff,et al.  Comparison of systolic time interval measurement modalities for portable devices , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[46]  Abraham Noordergraaf,et al.  An alternative to time-varying elastance descriptions of the heart , 1996, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[47]  Rui Pedro Paiva,et al.  Beat-to-beat cardiac output inference using heart sounds , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[48]  Roman Cmejla,et al.  Parameters for mean blood pressure estimation based on electrocardiography and photoplethysmography , 2011, 2011 International Conference on Applied Electronics.

[49]  Kalju Meigas,et al.  Pulse Wave Velocity in Continuous Blood Pressure Measurements , 2007 .

[50]  Richard P. Lewis,et al.  A Critical Review of the Systolic Time Intervals , 2005 .

[51]  Norbert Noury,et al.  A review of methods for non-invasive and continuous blood pressure monitoring: Pulse transit time method is promising? , 2014 .

[52]  Y.T. Zhang,et al.  Continuous and noninvasive estimation of arterial blood pressure using a photoplethysmographic approach , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[53]  Maxime Cannesson,et al.  Non-invasive continuous blood pressure monitoring: a review of current applications , 2013, Frontiers of Medicine.

[54]  I. Piña,et al.  Nuggets, pearls, and vignettes of master heart failure clinicians. Part 2-the physical examination. , 2001, Congestive heart failure.

[55]  T Yamamura,et al.  Arterial tonometry for noninvasive, continuous blood pressure monitoring during anesthesia. , 1991, Anesthesiology.

[56]  L. Peretto,et al.  A comparison study of two indirect methods for measuring the systolic pulmonary arterial pressure , 2011, 2011 IEEE International Symposium on Medical Measurements and Applications.

[57]  J. Pépin,et al.  Pulse transit time: an appraisal of potential clinical applications , 1999, Thorax.

[58]  R. Kattai,et al.  Continuous blood pressure monitoring during exercise using pulse wave transit time measurement , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[59]  J. Muehlsteff,et al.  Continuous cuff-less blood pressure monitoring based on the pulse arrival time approach: The impact of posture , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[60]  P. Chowienczyk,et al.  Evaluation of Carotid–Femoral Pulse Wave Velocity: Influence of Timing Algorithm and Heart Rate , 2005, Hypertension.

[61]  J. Furedy,et al.  Effects of psychological and physiological challenges on heart rate, T-wave amplitude, and pulse-transit time. , 1996, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[62]  C Longhini,et al.  A new noninvasive method for estimation of pulmonary arterial pressure in mitral stenosis. , 1991, The American journal of cardiology.

[63]  C. Ahlstrom,et al.  Noninvasive investigation of blood pressure changes using the pulse wave transit time: a novel approach in the monitoring of hemodialysis patients , 2005, Journal of Artificial Organs.

[64]  D Shapiro,et al.  Pulse transit time and blood pressure: an intensive analysis. , 1983, Psychophysiology.

[65]  C. Leier,et al.  Nuggets, pearls, and vignettes of master heart failure clinicians. Part 1--the medical history. , 2001, Congestive heart failure.

[66]  Yuan-Ting Zhang,et al.  A Model-based Study of Relationship between Timing of Second Heart Sound and Systolic Blood Pressure , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[67]  M. Masè,et al.  Feasibility of cuff-free measurement of systolic and diastolic arterial blood pressure. , 2011, Journal of electrocardiology.

[68]  T. Ma,et al.  A Correlation Study on the Variabilities in Pulse Transit Time, Blood Pressure, and Heart Rate Recorded Simultaneously from Healthy Subjects , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[69]  In-Young Kim,et al.  Comparative study on artificial neural network with multiple regressions for continuous estimation of blood pressure , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[70]  Dan Ventura,et al.  Noninvasive diagnosis of pulmonary hypertension using heart sound analysis , 2010, Comput. Biol. Medicine.

[71]  Guy D. Dumont,et al.  Continuous noninvasive blood pressure measurement by pulse transit time , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[72]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[73]  J. Stradling,et al.  Value of beat-to-beat blood pressure changes, detected by pulse transit time, in the management of the obstructive sleep apnoea/hypopnoea syndrome. , 1998, The European respiratory journal.

[74]  K. Park,et al.  Comparable parameter related to arterial stiffness in blood pressure estimation method , 2008, 2008 International Conference on Information Technology and Applications in Biomedicine.

[75]  T. Wibmer,et al.  Pulse transit time and blood pressure during cardiopulmonary exercise tests. , 2011, Physiological research.

[76]  Thomas Lauer,et al.  Predicting Neurally Mediated Syncope Based on Pulse Arrival Time: Algorithm Development and Preliminary Results , 2011, Journal of cardiovascular electrophysiology.

[77]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[78]  Jesús Lázaro,et al.  Deriving respiration from photoplethysmographic pulse width , 2013, Medical & Biological Engineering & Computing.

[79]  N. Lovell,et al.  Estimation of cardiac output and systemic vascular resistance using a multivariate regression model with features selected from the finger photoplethysmogram and routine cardiovascular measurements , 2013, Biomedical engineering online.

[80]  K. Uutela,et al.  Autonomic nervous system state: the effect of general anaesthesia and bilateral tonsillectomy after unilateral infiltration of lidocaine. , 2010, British journal of anaesthesia.

[81]  C. Lim,et al.  Evaluation of blood pressure changes using vascular transit time , 2006, Physiological measurement.

[82]  John Allen Photoplethysmography and its application in clinical physiological measurement , 2007, Physiological measurement.

[83]  Y.T. Zhang,et al.  The Effects of Exercises on the Relationship between Pulse Transit Time and Arterial Blood Pressure , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[84]  Marek Brzezinski,et al.  Radial Artery Cannulation: A Comprehensive Review of Recent Anatomic and Physiologic Investigations , 2009, Anesthesia and analgesia.

[85]  P. Obrist,et al.  Aortic-radial pulse transit time and ECG Q-wave to radial pulse wave interval as indices of beat-by-beat blood pressure change. , 1983, Psychophysiology.

[86]  Yutaka Imai,et al.  European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults , 2010, Blood pressure monitoring.

[87]  Boreom Lee,et al.  Enhancing the estimation of blood pressure using pulse arrival time and two confounding factors , 2010, Physiological measurement.

[88]  M Danielsen,et al.  Modeling ventricular contraction with heart rate changes. , 2003, Journal of theoretical biology.

[89]  Michael Böhm,et al.  Relationship between pulse transit time and blood pressure is impaired in patients with chronic heart failure , 2010, Clinical Research in Cardiology.

[90]  Gilwon Yoon,et al.  Non-constrained Blood Pressure Monitoring Using ECG and PPG for Personal Healthcare , 2009, Journal of Medical Systems.

[91]  Mehmet Rasit Yuce,et al.  A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time , 2015, Physiological measurement.

[92]  M. Tavel,et al.  Spectral analysis of heart sounds: relationships between some physical characteristics and frequency spectra of first and second heart sounds in normals and hypertensives. , 1984, Journal of biomedical engineering.

[93]  James N Kirkpatrick,et al.  Accuracy of noninvasively determined pulmonary artery systolic pressure. , 2010, The American journal of cardiology.

[94]  J. Fahrenberg,et al.  Methodological guidelines for impedance cardiography. , 1990, Psychophysiology.

[95]  L. Geddes,et al.  Measurements of Young's Modulus of Elasticity of the Canine Aorta with Ultrasound , 1979 .

[96]  Guanqun Zhang,et al.  Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure. , 2011, Journal of applied physiology.