Use of a sheath flow cuvette for chemiluminescence detection of isoluminol thiocarbamyl‐amino acids separated by capillary electrophoresis

A post-column reactor was designed for chemiluminescence detection in the capillary electrophoresis separation of isoluminol thiocarbamyl derivatives of amino acids. This system was characterized with respect to hydrogen peroxide concentration and flow rate, surfactant concentration, microperoxidase concentration, and mixing distance. A linear calibration curve (R >0.999) was constructed for isoluminol ranging from at least 30 femtomoles to the detection limit of 40 attomoles injected; the dynamic range of the instrument is at least three orders of magnitude. Detection limit for the isoluminol thiocarbamyl derivative of valine was 500 attomoles. The theoretical plate counts for the raw data are typically 1 × 105 for labeled amino acids, and a factor of two better for isoluminol.

[1]  H. Swerdlow,et al.  Low-cost, high-sensitivity laser-induced fluorescence detection for DNA sequencing by capillary gel electrophoresis. , 1991, Journal of chromatography.

[2]  N. Dovichi,et al.  Effect of total percent polyacrylamide in capillary gel electrophoresis for DNA sequencing of short fragments. A phenomenological model. , 1992, Journal of chromatography.

[3]  N. Dovichi,et al.  Separation of DNA sequencing fragments at 53 bases/minute by capillary gel electrophoresis , 1992 .

[4]  N. Dovichi,et al.  Interaction of capillary zone electrophoresis with a sheath flow cuvette detector , 1990 .

[5]  Melanie M. Cooper,et al.  A ChemiluminesClent Precolumn Labelling Reagent for High-Performance Liquid Chromatography of Amino Acids , 1986 .

[6]  H. R. Schroeder,et al.  Flow system for sensitive and reproducible chemiluminescence measurements , 1979 .

[7]  Mary Lynn Grayeski,et al.  Acridinium Chemiluminescence Detection with Capillary Electrophoresis , 1992 .

[8]  N. Dovichi,et al.  Capillary zone electrophoresis separation and laser-induced fluorescence detection of zeptomole quantities of fluorescein thiohydantoin derivatives of amino acids. , 1992, Talanta.

[9]  N. Dovichi,et al.  Low-cost laser-induced fluorescence detector for micellar capillary zone electrophoresis: Detection at the zeptomol level of tetramethylrhodamine thiocarbamyl amino acid derivatives , 1992 .

[10]  Norman J. Dovichi,et al.  Sub-picoliter detection with the sheath flow cuvette , 1985 .

[11]  N. Dovichi,et al.  High-sensitivity fluorescence detector fluorescein isothiocyanate derivatives of amino acids separated by capillary zone electrophoresis. , 1989, Journal of chromatography.

[12]  N. Dovichi,et al.  Formamide modified polyacrylamide gels for DNA sequencing by capillary gel electrophoresis , 1992, Electrophoresis.

[13]  N. Dovichi,et al.  Subattomole amino acid analysis by capillary zone electrophoresis and laser-induced fluorescence. , 1988, Science.

[14]  N. Dovichi,et al.  Sub-femtomole determination of phenylthiohydantoin-amino acids : capillary electrophoresis and thermooptical detection , 1992 .

[15]  T. Tsuda,et al.  Post-column detection for capillary zone electrophoresis , 1988 .

[16]  N. Dovichi,et al.  Attachment of a single fluorescent label to peptides for determination by capillary zone electrophoresis. , 1992, Journal of chromatography.

[17]  Donald J. Rose,et al.  Post-capillary fluorescence detection in capillary zone electrophoresis using o-phthaldialdehyde , 1988 .

[18]  J. Knoll Estimation of the limit of detection in chromatography , 1985 .

[19]  N. Dovichi,et al.  Two-label peak-height encoded DNA sequencing by capillary gel electrophoresis: three examples. , 1992, Nucleic acids research.

[20]  N. Dovichi,et al.  High-sensitivity laser-induced fluorescence detection for capillary electrophoresis. , 1991, Clinical chemistry.

[21]  H. Swerdlow,et al.  Three DNA sequencing methods using capillary gel electrophoresis and laser-induced fluorescence. , 1991, Analytical chemistry.

[22]  Richard N. Zare,et al.  Chemiluminescence detection in capillary electrophoresis , 1992 .