Bulk Current Injection in Twisted Wire Pairs With Not Perfectly Balanced Terminations

In this paper, common mode (CM) and differential mode (DM) voltages induced by bulk current injection at the terminations of a differential interconnection are predicted and correlated to the degree of unbalance of the terminal units. This is done by extending a previously derived lumped-parameter representation of the injection probe and by combining modal analysis with a multiconductor transmission line theory. Under nonrestrictive assumptions on termination unbalance, it is shown that CM and DM voltages can be readily predicted by two equivalent circuits. The circuit for CM prediction is independent on termination unbalance and directly excited by the injection probe. The circuit for DM prediction does not involve any of the probe model parameters, and is driven by two voltage sources related to the induced CM voltages through the common-mode rejection ratio of each termination. Model accuracy was proven by measurements carried out on a test bench setup according to the BCI Standards.

[1]  A. Orlandi,et al.  Grounding, unbalancing and length effects on termination voltages of a twinax cable during bulk current injection , 2004, IEEE Transactions on Electromagnetic Compatibility.

[2]  K. Yoshida,et al.  Experimental investigation of noise immunity diagnosis for printed circuit boards by bulk current injection test , 1999, 1999 International Symposium on Electromagnetic Compatibility (IEEE Cat. No.99EX147).

[3]  Flavia Grassi,et al.  Characterization of the bulk current injection calibration-jig for probe-model extraction , 2010, 2010 IEEE International Symposium on Electromagnetic Compatibility.

[4]  David A. Hill Currents induced on multiconductor transmission lines by radiation and injection , 1992 .

[5]  C. R. Paul,et al.  Decoupling the multiconductor transmission line equations , 1996 .

[6]  Stephan Frei,et al.  Modeling of Bulk Current Injection ( BCI ) Setups for Virtual Automotive IC Tests , 2010 .

[7]  Stephan Frei,et al.  Comparability of RF immunity test methods for IC design purposes , 2011, 2011 8th Workshop on Electromagnetic Compatibility of Integrated Circuits.

[8]  J. Cruz,et al.  Comparison measurements of currents induced by radiation and injection , 1992 .

[9]  A. Orlandi,et al.  Equivalent Circuit Model of a Bundle of Cables for Bulk Current Injection (BCI) Test , 2006, IEEE Transactions on Electromagnetic Compatibility.

[10]  G Spadacini,et al.  Plane-Wave Coupling to a Twisted-Wire Pair Above Ground , 2011, IEEE Transactions on Electromagnetic Compatibility.

[11]  Robert Sutton,et al.  The Excitation of Balanced Transmission Line Modes in Bulk Current Injection Measurements , 2009, 2009 20th International Zurich Symposium on Electromagnetic Compatibility.

[12]  F. Grassi,et al.  Use of Double Bulk Current Injection for Susceptibility Testing of Avionics , 2008, IEEE Transactions on Electromagnetic Compatibility.

[13]  F. Grassi,et al.  Immunity to Conducted Noise of Data Transmission Along DC Power Lines Involving Twisted-Wire Pairs Above Ground , 2013, IEEE Transactions on Electromagnetic Compatibility.

[14]  Paolo Stefano Crovetti,et al.  A critical assessment of the closed-loop Bulk Current Injection immunity test performed in compliance with ISO 11452-4 , 2010, 2010 IEEE International Symposium on Electromagnetic Compatibility.

[15]  C.-H. Huang,et al.  Conducted susceptibility diagnosis of vehicle electronic module using correlation between mixed-mode S-parameter measurement and bulk current injection test , 2009, 2009 3rd International Conference on Anti-counterfeiting, Security, and Identification in Communication.

[16]  Christos Christopoulos,et al.  Introduction to Electromagnetic Compatibility , 2007 .

[17]  Lawrence E. Crooks,et al.  Noise reduction techniques in electronic systems (2nd ed.), Henry W. Ott. Wiley‐Interscience, New York. 1988 , 1989 .

[18]  F. Grassi,et al.  Circuit Modeling of Injection Probes for Bulk Current Injection , 2007, IEEE Transactions on Electromagnetic Compatibility.

[19]  Michel F. Sultan Modeling of a Bulk Current Injection Setup for Susceptibility Threshold Measurements , 1986, 1986 IEEE International Symposium on Electromagnetic Compatibility.