Intermodulation-Based Nonlinear Smart Health Sensing of Human Vital Signs and Location

This paper discusses the use of a nonlinear sensing technology based on radio frequency (RF) intermodulation response to track both the vital signs and location of human subjects. Smart health sensing was realized through the use of a wearable nonlinear tag and an intermodulation-based nonlinear sensor operating in both Doppler and frequency shift keying (FSK) modes. The Doppler mode was used to detect the heartbeat and breathing of the target subject while human subject localization was achieved in the FSK mode. One of the key advantages of this nonlinear smart sensor system was clutter rejection. This system identified the signal reflected from the wearable nonlinear tag and suppressed undesired signals and interferences that were reflected from other objects. The wearable tags used for the experiments were passive, hence they did not require any battery or power supply for their operation. Since the respiration signal is typically stronger than the heartbeat signal, the nonlinear detection setup was designed such that the respiratory signal receives less gain to avoid its sidelobes and harmonics from interfering heartbeat signal detection. This enhanced the heartbeat signal quality so that the cardiac activity could be easily tracked. Four types of experiments were performed on multiple subjects to demonstrate the advantages of this intermodulation-based nonlinear smart health sensing system. Previously, 2nd order harmonics were utilized for target localization and vital sign monitoring. However, these 2nd order harmonics suffer from high path loss and licensing issues. In this paper, target localization and smart health sensing were realized using 3rd order intermodulation with less path loss and no licensing issues compared with its harmonic counterparts. The experiment performed in nonlinear FSK mode was able to detect and locate the source of motion with high accuracy. Similarly, vital signs were recorded in the nonlinear Doppler mode. The design effectively made the amplitude of the heartbeat signal component more prominent, so that the sidelobes and harmonics of respiration do not suppress heartbeat signal.

[1]  Mark S Rea,et al.  The NICU Lighted Environment. , 2016, Newborn and infant nursing reviews : NAINR.

[2]  Tomoaki Ohtsuki,et al.  Doppler Sensor-Based Blink Duration Estimation by Analysis of Eyelids Closing and Opening Behavior on Spectrogram , 2019, IEEE Access.

[3]  Khalid A. Qaraqe,et al.  Cognitive impairments in human brain due to wireless signals and systems: An experimental study using EEG signal analysis , 2013, 2013 IEEE 15th International Conference on e-Health Networking, Applications and Services (Healthcom 2013).

[4]  Nai-Chung Kuo,et al.  A High-Range-Accuracy and High-Sensitivity Harmonic Radar Using Pulse Pseudorandom Code for Bee Searching , 2013, IEEE Transactions on Microwave Theory and Techniques.

[5]  Bessam Abdulrazak,et al.  Nonintrusive Vital Signs Monitoring for Sleep Apnea Patients: A Preliminary Study , 2018, IEEE Access.

[6]  Van Nguyen,et al.  Denoised Maximum Likelihood Estimation of Chest Wall Displacement from the IR-UWB Spectrum , 2018, IEEE Access.

[7]  Aly E. Fathy,et al.  Comparison Study of Noncontact Vital Signs Detection Using a Doppler Stepped-Frequency Continuous-Wave Radar and Camera-Based Imaging Photoplethysmography , 2017, IEEE Transactions on Microwave Theory and Techniques.

[8]  Kyle A. Gallagher,et al.  HARMONIC RADAR: THEORY AND APPLICATIONS TONONLINEAR TARGET DETECTION, TRACKING, IMAGINGAND CLASSIFICATION , 2015 .

[9]  Ram M. Narayanan,et al.  Hardware Design of a High Dynamic Range Radio Frequency (RF) Harmonic Measurement System , 2018 .

[10]  Changzhi Li,et al.  A Low Power 5.8-GHz ISM-Band Intermodulation Radar System for Target Motion Discrimination , 2019, IEEE Sensors Journal.

[11]  Kehui Sun,et al.  Human Micro-Doppler Frequency Estimation Approach for Doppler Radar , 2018, IEEE Access.

[12]  Benjamin W. Berg,et al.  Microwave Stethoscope: Development and Benchmarking of a Vital Signs Sensor Using Computer-Controlled Phantoms and Human Studies , 2014, IEEE Transactions on Biomedical Engineering.

[13]  Jing Liang,et al.  Non-Contact Detection of Vital Signs Using a UWB Radar Sensor , 2019, IEEE Access.

[14]  Sung Ho Cho,et al.  Multi-Human Detection Algorithm Based on an Impulse Radio Ultra-Wideband Radar System , 2016, IEEE Access.

[15]  Tzuen-Hsi Huang,et al.  60-GHz Millimeter-Wave Life Detection System (MLDS) for Noncontact Human Vital-Signal Monitoring , 2012, IEEE Sensors Journal.

[16]  Changzhi Li,et al.  5.8-GHz ISM band intermodulation radar for high-sensitivity motion-sensing applications , 2018, 2018 IEEE Radio and Wireless Symposium (RWS).

[17]  Yu Jiang,et al.  Through Wall Human Detection Under Small Samples Based on Deep Learning Algorithm , 2018, IEEE Access.

[18]  Vladimir L. Petrović,et al.  High-Accuracy Real-Time Monitoring of Heart Rate Variability Using 24 GHz Continuous-Wave Doppler Radar , 2019, IEEE Access.

[19]  E. K. Miller,et al.  Time domain modeling of nonlinear loads , 1983 .

[20]  Karumudi Rambabu,et al.  Circularly Polarized Ultra-Wideband Radar System for Vital Signs Monitoring , 2013, IEEE Transactions on Microwave Theory and Techniques.

[21]  Amardeep Singh,et al.  Self-Identification Respiratory Disorder Based on Continuous Wave Radar Sensor System , 2019, IEEE Access.

[22]  F. Ellinger,et al.  Design of a 24 GHz FMCW radar system based on sub‐harmonic generation , 2018, IET Radar, Sonar & Navigation.

[23]  Jenshan Lin,et al.  Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring , 2004, IEEE Transactions on Microwave Theory and Techniques.

[24]  Changzhi Li,et al.  A Spectrum-Efficient FSK Radar Solution for Stationary Human Subject Localization Based on Vital Sign Signals , 2019, 2019 IEEE MTT-S International Microwave Symposium (IMS).

[25]  T. Sarkar,et al.  Scattering analysis of nonlinearly loaded antennas , 1975 .

[26]  Ke Wu,et al.  Noise and Sensitivity of Harmonic Radar Architecture for Remote Sensing and Detection of Vital Signs , 2014, IEEE Transactions on Microwave Theory and Techniques.

[27]  J. Lin,et al.  Experiment and Spectral Analysis of a Low-Power $Ka$-Band Heartbeat Detector Measuring From Four Sides of a Human Body , 2006, IEEE Transactions on Microwave Theory and Techniques.

[28]  George Shaker,et al.  Remote Monitoring of Human Vital Signs Using mm-Wave FMCW Radar , 2019, IEEE Access.

[29]  Andreas G. Andreou,et al.  Bio-Inspired Human Action Recognition With a Micro-Doppler Sonar System , 2018, IEEE Access.

[30]  Changzhi Li,et al.  Accuracy improvement in range measurements of short-range FSK radars , 2018, 2018 IEEE MTT-S International Wireless Symposium (IWS).