Optimization of a thermal slip sensor using FEM and dimensional analysis

During manipulation tasks it is important to maintain a precise and safe control of the grasping force. Slip detection plays a key role to assure an adequate adaptation of the grasping force, without object damaging. Several approaches to slip detection are currently under investigation. In particular, thermal slip sensors use a detection strategy similar to the one employed in hot wire anemometry, using a microfabricated thermal probe for detecting the convective heat flux associated to the movement of the touched object. This paper reports on the model-based optimization of a thermal slip sensor, intended for robotic prosthesis. In particular, an analytical thermal model has been developed, by merging FEM and dimensional analysis. A sensitivity analysis, performed on the parameters appearing in the model, has been performed for optimizing both sensor's geometry and materials in order to increase the heat flux and thereby to obtain a reduction of response times in the identification of slip. Simulations on the proposed design indicate an expected increase of the thermal dissipated power of about 400%.

[1]  Katsuhiko Nakamura,et al.  Instantaneous evaluation of friction based on ARTC tactile sensor , 2000, Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065).

[2]  Takashi Maeno,et al.  Artificial finger skin having ridges and distributed tactile sensors used for grasp force control , 2001, Proceedings 2001 IEEE/RSJ International Conference on Intelligent Robots and Systems. Expanding the Societal Role of Robotics in the the Next Millennium (Cat. No.01CH37180).

[3]  I. Fujimoto,et al.  Development of artificial finger skin to detect incipient slip for realization of static friction sensation , 2003, Proceedings of IEEE International Conference on Multisensor Fusion and Integration for Intelligent Systems, MFI2003..

[4]  Antonio Bicchi,et al.  Hands for dexterous manipulation and robust grasping: a difficult road toward simplicity , 2000, IEEE Trans. Robotics Autom..

[5]  Paolo Dario,et al.  A slip sensor for biorobotic applications using a hot wire anemometry approach , 2012 .

[6]  Roland S. Johansson,et al.  Afferent Signals During Manipulative Tasks in Humans , 1991 .

[7]  Katsuhiko Nakamura,et al.  Tactile Sensing Device Instantaneously Evaluating Friction Coefficients , 2001 .

[8]  Francesco Giovacchini,et al.  Artificial Roughness Encoding with a Bio-inspired MEMS- based Tactile Sensor Array , 2009, Sensors.

[9]  Sungchul Kang,et al.  Development of tactile sensor for detecting contact force and slip , 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[10]  J. Engel,et al.  Polymer micromachined multimodal tactile sensors , 2005 .

[11]  Neil M. White,et al.  Thick-film piezoelectric slip sensors for automatic grip control in prosthetic hands , 2007 .

[12]  M. Cutkosky,et al.  Manipulation Control with Dynamic Tactile Sensing , 1997 .

[13]  Claudio Melchiorri,et al.  Slip detection and control using tactile and force sensors , 2000 .

[14]  Mark R. Cutkosky,et al.  Sensing skin acceleration for slip and texture perception , 1989, Proceedings, 1989 International Conference on Robotics and Automation.

[15]  P. Chappell,et al.  Thick-film force and slip sensors for a prosthetic hand , 2005 .

[16]  John Kenneth Salisbury,et al.  Augmentation of grasp robustness using intrinsic tactile sensing , 1989, Proceedings, 1989 International Conference on Robotics and Automation.

[17]  Tsukasa Ogasawara,et al.  Grip force control for an elastic finger using vision-based incipient slip feedback , 2004, 2004 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (IEEE Cat. No.04CH37566).

[18]  Richard M. Crowder,et al.  A dynamic tactile sensor on photoelastic effect , 2006 .

[19]  G.E. Loeb,et al.  A robust micro-vibration sensor for biomimetic fingertips , 2008, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[20]  Takashi Maeno,et al.  Artificial finger skin having ridges and distributed tactile sensors used for grasp force control , 2002, Proceedings 2001 IEEE/RSJ International Conference on Intelligent Robots and Systems. Expanding the Societal Role of Robotics in the the Next Millennium (Cat. No.01CH37180).

[21]  R. Johansson,et al.  Responses in glabrous skin mechanoreceptors during precision grip in humans , 2004, Experimental Brain Research.

[22]  Tsutomu Hasegawa,et al.  Detection and measurement of fingertip slip in multi-fingered precision manipulation with rolling contact , 2001, Conference Documentation International Conference on Multisensor Fusion and Integration for Intelligent Systems. MFI 2001 (Cat. No.01TH8590).

[23]  Takayuki Koizumi,et al.  Slip detection with distributed-type tactile sensor , 2004, 2004 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (IEEE Cat. No.04CH37566).

[24]  Minoru Asada,et al.  Internal representation of slip for a soft finger with vision and tactile sensors , 2002, IEEE/RSJ International Conference on Intelligent Robots and Systems.