Simultaneous determination of adenine and guanine utilizing PbO2-carbon nanotubes-ionic liquid composite film modified glassy carbon electrode

Abstract A novel and reliable electrochemical sensor based on PbO 2 -carbon nanotubes-room temperature ionic liquid (i.e., 1-butyl-3-methylimidazolium hexafluorophosphate, BMIMPF6) composite film modified glassy carbon electrode (GCE) (PbO 2 –MWNT–RTIL/GCE) was proposed for simultaneous and individual determination of guanine and adenine. The guanine and adenine oxidation responses were monitored by differential pulse voltammetric (DPV) measurement. Compared with the bare electrode, the PbO 2 –MWNT–RTIL/GCE not only significantly enhanced the oxidation peak currents of guanine and adenine, but also lowered their oxidation overpotentials, suggesting that the synergistic effect of PbO 2 , MWNT and RTIL could dramatically improve the determining sensitivity of guanine and adenine. The PbO 2 –MWNT–RTIL/GCE showed good stability, high accumulation efficiency and enhanced electrocatalytic ability for the detection of guanine and adenine. Besides, the modified electrode also exhibited good behaviors in the simultaneous detection of adenine and guanine with the peak separation of 0.29 V in 0.1 M pH 7.0 phosphate buffer solution (PBS). Under the optimal conditions, the detection limit for individual determination of guanine and adenine was 6.0 × 10 −9  M and 3.0 × 10 −8  M ( S / N  = 3), respectively. The proposed method for the measurements of guanine and adenine in herring sperm DNA was successfully applied with satisfactory results.

[1]  Ying Liu,et al.  Electrochemical and bioelectrochemistry properties of room-temperature ionic liquids and carbon composite materials. , 2004, Analytical chemistry.

[2]  S. Ferro,et al.  Electrocatalytic oxidation of p-nitrophenol from aqueous solutions at Pb/PbO2 anodes , 2005 .

[3]  J. Davidson,et al.  Progress in nucleic acid research , 1963 .

[4]  R. Zare,et al.  Selective determination of adenine-containing compounds by capillary electrophoresis with laser-induced fluorescence detection. , 1994, Analytical biochemistry.

[5]  Wei Sun,et al.  Direct electrocatalytic oxidation of adenine and guanine on carbon ionic liquid electrode and the simultaneous determination. , 2008, Biosensors & bioelectronics.

[6]  Huangxian Ju,et al.  Rapid detection of ssDNA and RNA using multi-walled carbon nanotubes modified screen-printed carbon electrode. , 2005, Biosensors & bioelectronics.

[7]  E. Laviron General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems , 1979 .

[8]  Hongyuan Chen,et al.  Determination of purine bases by capillary zone electrophoresis with wall-jet amperometric detection , 1996 .

[9]  Wei Zhang,et al.  An ionic liquid supported CeO2 nanoshuttles-carbon nanotubes composite as a platform for impedance DNA hybridization sensing. , 2009, Biosensors & bioelectronics.

[10]  Hongyuan Chen,et al.  Simultaneous determination of guanine and adenine in DNA using an electrochemically pretreated glassy carbon electrode , 2002 .

[11]  Qing Yang,et al.  Artificial neural network classification based on high-performance liquid chromatography of urinary and serum nucleosides for the clinical diagnosis of cancer. , 2002, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[12]  Guo-Li Shen,et al.  Functionalization of multi-walled carbon nanotubes with poly(amidoamine) dendrimer for mediator-free glucose biosensor , 2007 .

[13]  A. Velichenko,et al.  Electrosynthesis and physicochemical properties of Fe-doped lead dioxide electrocatalysts , 2000 .

[14]  N. Kuroda,et al.  Chemiluminescence method for the determination of adenine after reaction with phenylglyoxal , 1993 .

[15]  A. Abbaspour,et al.  Electrocatalytic oxidation of guanine and ss-DNA at a cobalt (II) phthalocyanine modified carbon paste electrode , 2004 .

[16]  Umasankar Yogeswaran,et al.  Pinecone shape hydroxypropyl -β -cyclodextrin on a film of multi-walled carbon nanotubes coated with gold particles for the simultaneous determination of tyrosine, guanine, adenine and thymine , 2007 .

[17]  A. Gopalan,et al.  Synergistic contributions of multiwall carbon nanotubes and gold nanoparticles in a chitosan–ionic liquid matrix towards improved performance for a glucose sensor , 2009 .

[18]  P. Eklund,et al.  Debundling and dissolution of single-walled carbon nanotubes in amide solvents. , 2004, Journal of the American Chemical Society.

[19]  Shengshui Hu,et al.  Direct electrochemistry of DNA, guanine and adenine at a nanostructured film-modified electrode , 2003, Analytical and bioanalytical chemistry.

[20]  Q. Ma,et al.  Facile preparation of PbO2 electrode for the electrochemical inactivation of microorganisms , 2009 .

[21]  Zonghua Wang,et al.  β-Cyclodextrin incorporated carbon nanotubes-modified electrodes for simultaneous determination of adenine and guanine , 2006 .

[22]  Joseph Wang,et al.  Carbon-nanotube-modified glassy carbon electrodes for amplified label-free electrochemical detection of DNA hybridization. , 2003, The Analyst.

[23]  F. Zhao,et al.  Sensitive voltammetric determination of chloramphenicol by using single-wall carbon nanotube-gold nanoparticle-ionic liquid composite film modified glassy carbon electrodes. , 2007, Analytica chimica acta.

[24]  E. Laviron The use of linear potential sweep voltammetry and of a.c. voltammetry for the study of the surface electrochemical reaction of strongly adsorbed systems and of redox modified electrodes , 1979 .

[25]  Lixian Sun,et al.  Direct electron transfer of cytochrome c and its biosensor based on gold nanoparticles/room temperature ionic liquid/carbon nanotubes composite film , 2008 .

[26]  Umasankar Yogeswaran,et al.  Simultaneous determination of adenine guanine and thymine at multi-walled carbon nanotubes incorporated with poly(new fuchsin) composite film. , 2009, Analytica chimica acta.

[27]  Meng Zhang,et al.  Selected-control synthesis of PbO 2 submicrometer-sized hollow spheres and Pb 3 O 4 microtubes , 2004 .

[28]  W. Jin,et al.  Determination of adenine and guanine by capillary zone electrophoresis with end‐column amperometric detection at a carbon fiber microdisk array electrode , 1997 .