Model Development and Field Testing of a Heavy-Duty Gas-Turbine Generator

This paper presents a detailed account of model development for a heavy-duty gas-turbine generator, based on field testing. Some salient points are discussed. These include a more elegant way of modeling the ambient temperature and frequency dependence of the turbine power output, the deadband in the governor response and the importance of modeling the excitation system limiters for system studies.

[1]  Ieee Standards Board IEEE recommended practice for excitation system models for power system stability studies , 1992 .

[2]  Dmitry Kosterev,et al.  New thermal governor model selection and validation in the WECC , 2004 .

[3]  P. Pourbeik,et al.  Model validation testing for the purpose of determining generation equipment dynamic performance and torsional mechanical response , 2004, IEEE Power Engineering Society General Meeting, 2004..

[4]  G. R. Berube,et al.  Utility experience with gas turbine testing and modeling , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).

[5]  D. Kosterev,et al.  A new thermal governor modeling approach in the WECC , 2003 .

[6]  R. Berube,et al.  Guidelines for Generator Stability Model Validation Testing , 2007, 2007 IEEE Power Engineering Society General Meeting.

[7]  S. Ihara,et al.  Modeling frequency dependency of gas turbine output , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).

[8]  I. Kamwa,et al.  Experience with standstill frequency response (SSFR) testing and analysis of salient pole synchronous machines , 1999 .