Multiple active–passive tuned mass dampers for structures under the ground acceleration

An Erratum has been published for this article in Earthquake Engineering and Structural Dynamics 2003; 32(15):2451. Multiple active–passive tuned mass dampers (MAPTMD) consisting of many active–passive tuned mass dampers (APTMDs) with a uniform distribution of natural frequencies have been, for the first time here, proposed for attenuating undesirable oscillations of structures under the ground acceleration. The MAPTMD is manufactured by keeping the stiffness and damping coefficient constant and varying the mass. The control forces in the MAPTMD are generated through keeping the identical displacement and velocity feedback gain and varying the acceleration feedback gain. The structure is represented by the mode-generalized system corresponding to the specific vibration mode that needs to be controlled. Through minimization of the minimum values of the maximum dynamic magnification factors (DMF) of the structure with the MAPTMD (i.e. through implementation of Min.Min.Max.DMF), the optimum parameters of the MAPTMD are investigated to delineate the influence of the important parameters such as mass ratio, total number, normalized acceleration feedback gain coefficient and system parameter ratio on the effectiveness (i.e. Min.Min.Max.DMF) and robustness of the MAPTMD. The optimum parameters of the MAPTMD include the optimum frequency spacing, average damping ratio and tuning frequency ratio. Additionally, for the sake of comparison, the results for a single APTMD are also taken into account in the present paper. It is demonstrated that the proposed MAPTMD can be employed to significantly reduce the oscillations of structures under the ground acceleration. Also, it is shown that the MAPTMD can render high robustness and has better effectiveness than a single APTMD. In particularly, if and when requiring a large active control force, MAPTMD is more promising for practical implementations on seismically excited structures with respect to a single APTMD. Copyright © 2003 John Wiley & Sons, Ltd.

[1]  Jann N. Yang,et al.  Reduced-order H∞ and LQR control for wind-excited tall buildings , 1998 .

[2]  T. T. Soong,et al.  STRUCTURAL CONTROL USING ACTIVE TUNED MASS DAMPERS , 1980 .

[3]  Ahsan Kareem,et al.  Performance of Multiple Mass Dampers Under Random Loading , 1995 .

[4]  Chunxiang Li,et al.  Optimum multiple tuned mass dampers for structures under the ground acceleration based on the uniform distribution of system parameters , 2003 .

[5]  R. S. Jangid Optimum Multiple Tuned Mass Dampers for base‐excited undamped system , 1999 .

[6]  Masato Abe,et al.  Tuned mass dampers for structures with closely spaced natural frequencies , 1995 .

[7]  Henry T. Y. Yang,et al.  Simple ATMD Control Methodology for Tall Buildings Subject to Wind Loads , 1996 .

[8]  Mohamed Abdel-Rohman,et al.  Optimal design of active TMD for buildings control , 1984 .

[9]  Thambirajah Balendra,et al.  Control on Dynamic Structural Response Using Active-Passive Composite-Tuned Mass Dampers , 1999 .

[10]  Dorothy Reed,et al.  Analysis of uniformly and linearly distributed mass dampers under harmonic and earthquake excitation , 2001 .

[11]  Thambirajah Balendra,et al.  Optimal Damper Characteristics of ATMD for Buildings under wind Loads , 1999 .

[12]  Henry T.Y. Yang,et al.  CONTROL OF BUILDINGS USING ACTIVE TUNED MASS DAMPERS , 1995 .

[13]  Takuji Kobori,et al.  Acceleration feedback method applied to active-passive composite tuned mass damper , 1994 .

[14]  Chunxiang Li,et al.  Active multiple tuned mass dampers for structures under the ground acceleration , 2002 .

[15]  K. Xu,et al.  Dynamic characteristics of multiple substructures with closely spaced frequencies , 1992 .

[16]  Isao Nishimura,et al.  Active tuned mass damper , 1992 .

[17]  Chunxiang Li Performance of multiple tuned mass dampers for attenuating undesirable oscillations of structures under the ground acceleration , 2000 .

[18]  Y. Fujino,et al.  Dynamic characterization of multiple tuned mass dampers and some design formulas , 1994 .

[19]  Chunxiang Li,et al.  Optimum multiple tuned mass dampers for structures under the ground acceleration based on DDMF and ADMF , 2002 .

[20]  H. Yamaguchi,et al.  Fundamental characteristics of Multiple Tuned Mass Dampers for suppressing harmonically forced oscillations , 1993 .