Direct detection of bacterial genomic DNA at sub-femtomolar concentrations using single molecule arrays.

We report a method for the sensitive measurement of genomic DNA based on the direct detection of single molecules of DNA in arrays of femtoliter wells. The method begins by generating short fragments of DNA from large, double-stranded molecules of genomic DNA using either restriction enzymes or sonication. Single-stranded fragments are then generated by melting the duplex, and these fragments are hybridized to complementary biotinylated detection probes and capture probes on paramagnetic beads. The resulting DNA complexes are then labeled with an enzyme (streptavidin-β-galactosidase), and single enzymes associated with these complexes on beads are detected in single molecule arrays (Simoa). DNA concentration is quantified by determining the average number of enzymes per bead via Poisson statistics (digital) or the average bead intensity (analog). The Simoa DNA assay was used to detect genomic DNA purified from S. aureus with an average limit of detection (LOD) of 0.07 fM, or 2100 DNA molecules per 50 μL sample. We used this assay to detect S. aureus spiked into (a) whole blood, with an average LOD of 1100 bacteria per 25 μL sample (0.074 fM), and (b) water from the Charles River, with an LOD of 1300 bacteria per 50 μL sample (0.042 fM). Bacteria were detected in river water without prior purification of DNA. The Simoa DNA assay, which directly detects target DNA molecules without molecular replication, is an attractive alternative to existing sensitive DNA detection technologies that rely on amplification using polymerases, such as the polymerase chain reaction (PCR).

[1]  J. Costerton,et al.  Bacterial doubling time modulates the effects of opsonisation and available iron upon interactions between Staphylococcus aureus and human neutrophils. , 1996, FEMS immunology and medical microbiology.

[2]  Preeti Pancholi,et al.  Molecular methods and platforms for infectious diseases testing a review of FDA-approved and cleared assays. , 2011, The Journal of molecular diagnostics : JMD.

[3]  K. Mullis,et al.  Specific synthesis of DNA in vitro via a polymerase-catalyzed chain reaction. , 1987, Methods in enzymology.

[4]  D. Alland,et al.  Highly Sensitive Detection of Staphylococcus aureus Directly from Patient Blood , 2012, PloS one.

[5]  Reza Alaeddini Forensic implications of PCR inhibition--A review. , 2012, Forensic science international. Genetics.

[6]  David H Wilson,et al.  Simultaneous detection of single molecules and singulated ensembles of molecules enables immunoassays with broad dynamic range. , 2011, Analytical chemistry.

[7]  Viswanadham Garimella,et al.  Homogeneous detection of unamplified genomic DNA sequences based on colorimetric scatter of gold nanoparticle probes , 2004, Nature Biotechnology.

[8]  D. Norwood,et al.  Detection of biological threat agents by real-time PCR: comparison of assay performance on the R.A.P.I.D., the LightCycler, and the Smart Cycler platforms. , 2006, Clinical chemistry.

[9]  Jennifer L. Osborn,et al.  Direct multiplexed measurement of gene expression with color-coded probe pairs , 2008, Nature Biotechnology.

[10]  L. Putignani,et al.  Multiplex PCR Allows Rapid and Accurate Diagnosis of Bloodstream Infections in Newborns and Children with Suspected Sepsis , 2011, Journal of Clinical Microbiology.

[11]  Pierre Servais,et al.  Detection and enumeration of coliforms in drinking water: current methods and emerging approaches. , 2002, Journal of microbiological methods.

[12]  A. Fluit,et al.  False-Positive Results and Contamination in Nucleic Acid Amplification Assays: Suggestions for a Prevent and Destroy Strategy , 2004, European Journal of Clinical Microbiology and Infectious Diseases.

[13]  Gregory J Tsongalis,et al.  Molecular diagnostics: a historical perspective. , 2006, Clinica chimica acta; international journal of clinical chemistry.

[14]  K. Holmstrøm,et al.  Inhibition of PCR by components of food samples, microbial diagnostic assays and DNA-extraction solutions. , 1992, International journal of food microbiology.

[15]  Bryan R Cobb,et al.  Evolution in the sensitivity of quantitative HIV-1 viral load tests. , 2011, Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology.

[16]  Florence Postollec,et al.  Recent advances in quantitative PCR (qPCR) applications in food microbiology. , 2011, Food microbiology.

[17]  Zhaohui Li,et al.  Detection of single-molecule DNA hybridization using enzymatic amplification in an array of femtoliter-sized reaction vessels. , 2008, Journal of the American Chemical Society.

[18]  David H Wilson,et al.  Single molecule enzyme-linked immunosorbent assays: theoretical considerations. , 2012, Journal of immunological methods.

[19]  Richard J. Roberts,et al.  NEBcutter: a program to cleave DNA with restriction enzymes , 2003, Nucleic Acids Res..

[20]  M. Sobsey,et al.  Reducing the effects of environmental inhibition in quantitative real-time PCR detection of adenovirus and norovirus in recreational seawaters. , 2012, Journal of virological methods.

[21]  Chad A Mirkin,et al.  Bio-bar-code-based DNA detection with PCR-like sensitivity. , 2004, Journal of the American Chemical Society.

[22]  Dennis C. Friedrich,et al.  A scalable, fully automated process for construction of sequence-ready human exome targeted capture libraries , 2011, Genome Biology.

[23]  David M. Rissin,et al.  Single-Molecule enzyme-linked immunosorbent assay detects serum proteins at subfemtomolar concentrations , 2010, Nature Biotechnology.

[24]  J. Paul,et al.  Quantification of Human Polyomaviruses JC Virus and BK Virus by TaqMan Quantitative PCR and Comparison to Other Water Quality Indicators in Water and Fecal Samples , 2009, Applied and Environmental Microbiology.

[25]  M. Clementi,et al.  The Era of Molecular and Other Non-Culture-Based Methods in Diagnosis of Sepsis , 2010, Clinical Microbiology Reviews.

[26]  M. Busch,et al.  Nucleic acid amplification technology methods used in blood donor screening , 2002, Transfusion medicine.

[27]  M. Lechevallier,et al.  Bacterial Contamination of Drinking Water Supplies in a Modern Rural Neighborhood , 1980, Applied and environmental microbiology.

[28]  J. Werner,et al.  Copyright � 1995, American Society for Microbiology Inhibition of PCR by Aqueous and Vitreous Fluids , 1994 .

[29]  I G Wilson,et al.  Inhibition and facilitation of nucleic acid amplification , 1997, Applied and environmental microbiology.

[30]  K. Ramotar,et al.  Inhibition of PCR in Genital and Urine Specimens Submitted for Chlamydia trachomatis Testing , 1998, Journal of Clinical Microbiology.

[31]  J. Maurer Rapid detection and limitations of molecular techniques. , 2011, Annual review of food science and technology.

[32]  G. Tsongalis Branched DNA technology in molecular diagnostics. , 2006, American journal of clinical pathology.