Fluorescence lifetime imaging in scanning microscopes: acquisition speed, photon economy and lifetime resolution

In this paper a detailed discussion is presented of the factors that affect the fluorescence lifetime imaging performance of a scanning microscope equipped with a single photon counting based, two‐ to eight‐channel, time‐gated detection system. In particular we discuss the sensitivity, lifetime resolution, acquisition speed, and the shortest lifetimes that can be measured. Detection systems equipped with four to eight time‐gates are significantly more sensitive than the two time‐gate system. Only minor sensitivity differences were found between systems with four or more time‐gates. Experiments confirm that the lifetime resolution is dominated by photon statistics. The time response of the detector determines the shortest lifetimes that can be resolved; about 25 ps for fast MCP‐PMTs and 300–400 ps for other detectors. The maximum count rate of fast MCP‐PMTs, however, is 10–100 times lower than that of fast PMTs. Therefore, the acquisition speed with MCP‐PMT based systems is limited. With a fast PMT operated close to its maximum count rate we were able to record a fluorescence lifetime image of a beating myocyte in less than one second.

[1]  James N. Demas,et al.  Excited State Lifetime Measurements , 1983 .

[2]  William H. Press,et al.  The Art of Scientific Computing Second Edition , 1998 .

[3]  David M. Coleman,et al.  A Two-Dimensional Fluorescence Lifetime Imaging System Using a Gated Image Intensifier , 1991 .

[4]  Joseph R. Lakowicz,et al.  Fluorescence lifetime-based sensing of pH, Ca2+, K+ and glucose , 1993 .

[5]  Richard N. Day,et al.  Nanosecond fluorescence resonance energy transfer‐fluorescence lifetime imaging microscopy to localize the protein interactions in a single living cell , 2002, Journal of microscopy.

[6]  H. Schneckenburger,et al.  Fluorescence decay kinetics and imaging of NAD(P)H and flavins as metabolic indicators , 1992 .

[7]  Jürgen Wolfrum,et al.  How many photons are necessary for fluorescence-lifetime measurements? , 1992 .

[8]  H. Gerritsen,et al.  Multiple Time-Gate Module for Fluorescence Lifetime Imaging , 2001 .

[9]  Sytsma,et al.  Time‐gated fluorescence lifetime imaging and microvolume spectroscopy using two‐photon excitation , 1998 .

[10]  F. A. Seiler,et al.  Numerical Recipes in C: The Art of Scientific Computing , 1989 .

[11]  Robert M. Clegg,et al.  Fluorescence lifetime imaging microscopy (FLIM): Spatial resolution of microstructures on the nanosecond time scale , 1993 .

[12]  J. Berlin,et al.  Ca2+ transients in cardiac myocytes measured with high and low affinity Ca2+ indicators. , 1993, Biophysical journal.

[13]  David J. S. Birch,et al.  Multiplexed single-photon counting. I. A time-correlated fluorescence lifetime camera , 1996 .

[14]  Hans C. Gerritsen,et al.  Fluorescence lifetime imaging using a confocal laser scanning microscope , 1992 .

[15]  H Szmacinski,et al.  Fluorescence lifetime imaging. , 1992, Analytical biochemistry.

[16]  Anthony W. Parker,et al.  Application of fluorescence lifetime imaging microscopy to the investigation of intracellular PDT mechanisms , 1997 .

[17]  Joseph R. Lakowicz,et al.  Lifetime‐selective fluorescence imaging using an rf phase‐sensitive camera , 1991 .

[18]  Hans C. Gerritsen,et al.  Fluorescence Lifetime Imaging, a New Tool in Confocal Microscopy , 1995 .

[19]  F. Wouters,et al.  Fluorescence lifetime imaging of receptor tyrosine kinase activity in cells , 1999, Current Biology.

[20]  R. Ballew,et al.  An error analysis of the rapid lifetime determination method for the evaluation of single exponential decays , 1989 .