Lateral supra-acetabular external fixation for unstable pelvic ring fracture: A biomechanical assessments

Unstable pelvic ring fractures are usually affiliated with high energy impact that inflicted upon the hip such as in vehicle, industrial and extreme sport accidents. These injuries are always associated with high rate of mortality due to excessive bleeding and involvement of surrounding organs. Early stabilization of the pelvic using an external fixation can be used to reduce the pelvic volume and consequently control the hemorrhage. However, not a single currently available external fixations are capable of stabilizing the unstable fracture sufficient enough to allow patient mobilization and early weight bearing. Hence, this study was conducted to introduce a new method of fixation known as lateral supra-acetabular and subsequently compare with anterosuperior and anteroinferior fixation methods. The comparison was made by means of physical experimentation and computer simulation. The physical experiment employed four sawbone models while the simulation was performed using virtual pelvic model reconstructed from an MDCT image with Type C1 fracture. Both experiment and simulation were performed for standing and sitting position to evaluate the strength of fixation before failure of the model occurs. Lateral supra-acetabular fixation method was found to be significantly performed better than anterosuperior and anteroinferior fixation for both physical experiment and computer simulation.

[1]  Michael J Gardner,et al.  Stabilization of unstable pelvic fractures with supraacetabular compression external fixation. , 2007, Journal of orthopaedic trauma.

[2]  D. Wetterkamp,et al.  Clinical and biomechanical aspects of external fixation of the pelvis. , 1996, Clinical biomechanics.

[3]  George J. Haidukewych,et al.  Placement of Half-Pins for Supra-acetabular External Fixation: An Anatomic Study , 2003, Clinical orthopaedics and related research.

[4]  D Havemann,et al.  [Stabilizing the pelvic ring with the external fixator. Biomechanical studies and clinical experiences]. , 1992, Der Orthopade.

[5]  D. Mears,et al.  External fixation of the pelvis. , 1983, Instructional course lectures.

[6]  Christian Krettek,et al.  Supraacetabular External Fixation for Pelvic Ring Fractures , 2006, European Journal of Trauma.

[7]  Michelangelo Scaglione,et al.  External fixation in pelvic fractures , 2010, Musculoskeletal surgery.

[8]  Robert K. Clark Anatomy and Physiology: Understanding the Human Body , 2005 .

[9]  M Tile,et al.  Pelvic ring fractures: should they be fixed? , 1988, The Journal of bone and joint surgery. British volume.

[10]  Lucian B Solomon,et al.  The Subcristal Pelvic External Fixator: Technique, Results, and Rationale , 2009, Journal of orthopaedic trauma.

[11]  Roland Kebel,et al.  Orthogonal Pin Construct Versus Parallel Uniplanar Pin Constructs for Pelvic External Fixation: A Biomechanical Assessment of Stiffness and Strength , 2009, Journal of orthopaedic trauma.

[12]  Xiaoxi Ji,et al.  Supra‐acetabular external fixation for pelvic fractures: A digital anatomical study , 2012, Clinical anatomy.

[13]  D. C. Mears,et al.  Comparative mechanical performances of some new devices for fixation of unstable pelvic ring fractures , 1983, Medical and Biological Engineering and Computing.

[14]  A. Poka,et al.  Indications and techniques for external fixation of the pelvis. , 1996, Clinical orthopaedics and related research.

[15]  Rahul Banerjee,et al.  Indirect reduction of bilateral tilt fractures using a supra-acetabular pelvic external fixator. , 2010, The Journal of trauma.

[16]  T C Hearn,et al.  Effect of pin location on stability of pelvic external fixation. , 1999, Clinical orthopaedics and related research.

[17]  P. Giannoudis,et al.  Biomechanical aspects of pelvic ring reconstruction techniques: Evidence today. , 2010, Injury.

[18]  R. T. Hutchings,et al.  The Human Skeleton , 2009 .