Correlation analysis of the puncture-side bone cement/vertebral body volume ratio and bone cement leakage in the paravertebral vein in vertebroplasty
暂无分享,去创建一个
Chao Wu | Tao Li | Dechao Yuan | Haigang Hu | Xuezhi Lin | Jun Zeng | Tao Gao | Zhiwei Chen | Zhi-Yu Chen
[1] Pei-Xun Zhang,et al. Risk factors for cement leakage and nomogram for predicting the intradiscal cement leakage after the vertebra augmented surgery , 2020, BMC Musculoskeletal Disorders.
[2] Zi-Jun Liu,et al. Effect of unilateral pulsed jet lavage prior to vertebroplasty on the intravertebral pressure and cement distribution , 2020, Journal of Orthopaedic Surgery and Research.
[3] A. Arana-Guajardo,et al. Asymptomatic pulmonary embolism secondary to cement leakage after vertebroplasty. , 2020, Reumatologia clinica.
[4] R. Tubbs,et al. Venous Drainage of the Lumbar Vertebral Bodies: An Anatomical Study with Application to Kyphoplasty, Vertebroplasty and Pedicle Screw Complications. , 2020, World neurosurgery.
[5] C. Niu,et al. Risk factors of neurological deficit and pulmonary cement embolism after percutaneous vertebroplasty , 2019, Journal of Orthopaedic Surgery and Research.
[6] M. Kong,et al. Clinical characteristics and management of cardiac and/or pulmonary cement embolus after percutaneous vertebroplasty: a single center experience. , 2019, Annals of translational medicine.
[7] S. D’Errico,et al. Fatal cardiac perforation and pulmonary embolism of leaked cement after percutaneous vertebroplasty. , 2019, Journal of forensic and legal medicine.
[8] Jun Liu,et al. Influence of vertebral bone mineral density on total dispersion volume of bone cement in vertebroplasty , 2019, Medicine.
[9] Lifeng Lao,et al. Bone cement distribution is a potential predictor to the reconstructive effects of unilateral percutaneous kyphoplasty in OVCFs: a retrospective study , 2018, Journal of Orthopaedic Surgery and Research.
[10] M. Qi,et al. The Optimal Volume Fraction in Percutaneous Vertebroplasty Evaluated by Pain Relief, Cement Dispersion, and Cement Leakage: A Prospective Cohort Study of 130 Patients with Painful Osteoporotic Vertebral Compression Fracture in the Thoracolumbar Vertebra. , 2018, World neurosurgery.
[11] Publisher's Note , 2018, Anaesthesia.
[12] Jian-zhong Jiang,et al. Risk Factors for Cement Leakage After Vertebroplasty or Kyphoplasty: A Meta-Analysis of Published Evidence. , 2017, World neurosurgery.
[13] Zihui Zhou,et al. Is There a Dose–Response Relationship of Cement Volume With Cement Leakage and Pain Relief After Vertebroplasty? , 2016, Dose-response : a publication of International Hormesis Society.
[14] Sang Pyung Lee,et al. Appropriate Cement Volume in Vertebroplasty: A Multivariate Analysis with Short-Term Follow-Up , 2016, Korean journal of neurotrauma.
[15] A. Ashour,et al. Vertebral augmentation by kyphoplasty and vertebroplasty: 8 years experience outcomes and complications , 2016, Journal of craniovertebral junction & spine.
[16] Jianting Chen,et al. Risk factors for bone cement leakage in percutaneous vertebroplasty: a retrospective study of four hundred and eighty five patients , 2016, International Orthopaedics.
[17] P. Jarzem,et al. Pulmonary Artery Cement Embolism after a Vertebroplasty , 2015, Case reports in orthopedics.
[18] D. Liang,et al. [Correlation analysis of cement leakage with volume ratio of intravertebral bone cement to vertebral body and vertebral body wall incompetence in percutaneous vertebroplasty for osteoporotic vertebral compression fractures]. , 2014, Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery.
[19] F. Cannizzaro,et al. Asymptomatic Bone Cement Pulmonary Embolism after Vertebroplasty: Case Report and Literature Review , 2013, Case reports in surgery.
[20] Liang Chen,et al. Pulmonary Cement Embolism Associated with Percutaneous Vertebroplasty or Kyphoplasty: A Systematic Review , 2012, Orthopaedic surgery.
[21] M. Reiser,et al. CT fluoroscopy-guided percutaneous vertebroplasty in spinal malignancy: technical results, PMMA leakages, and complications in 202 patients , 2012, Skeletal Radiology.
[22] C. Cox,et al. Investigation of polymethylmethacrylate pulmonary embolus in a patient ten years following vertebroplasty. , 2011, Journal of radiology case reports.
[23] D. Kallmes,et al. Asymptomatic and Unrecognized Cement Pulmonary Embolism Commonly Occurs with Vertebroplasty , 2011, American Journal of Neuroradiology.
[24] M. Raza. Pulmonary Cement Embolism after Percutaneous Vertebroplasty in Osteoporotic Vertebral Compression Fractures: Incidence, Characteristics, and Risk Factors , 2010 .
[25] Heung Sik Kang,et al. Pulmonary cement embolism after percutaneous vertebroplasty in osteoporotic vertebral compression fractures: incidence, characteristics, and risk factors. , 2009, Radiology.
[26] S. Ferguson,et al. Vertebroplasty and Kyphoplasty: A Systematic Review of 69 Clinical Studies , 2006, Spine.
[27] S Sawada,et al. Percutaneous vertebroplasty for compression fracture: analysis of vertebral body volume by CT volumetry , 2005, Acta radiologica.
[28] K. Ahrar,et al. Pulmonary embolism of polymethyl methacrylate during percutaneous vertebroplasty and kyphoplasty. , 2004, AJR. American journal of roentgenology.
[29] J. Theis,et al. Pressurization of Vertebral Bodies During Vertebroplasty Causes Cardiovascular Complications: An Experimental Study in Sheep , 2003, Spine.
[30] Christoph Fankhauser,et al. Augmentation of mechanical properties in osteoporotic vertebral bones – a biomechanical investigation of vertebroplasty efficacy with different bone cements , 2001, European Spine Journal.
[31] M. A. Glasby,et al. AN EXPERIMENTAL STUDY IN SHEEP , 1994 .