Correlation analysis of the puncture-side bone cement/vertebral body volume ratio and bone cement leakage in the paravertebral vein in vertebroplasty

[1]  Pei-Xun Zhang,et al.  Risk factors for cement leakage and nomogram for predicting the intradiscal cement leakage after the vertebra augmented surgery , 2020, BMC Musculoskeletal Disorders.

[2]  Zi-Jun Liu,et al.  Effect of unilateral pulsed jet lavage prior to vertebroplasty on the intravertebral pressure and cement distribution , 2020, Journal of Orthopaedic Surgery and Research.

[3]  A. Arana-Guajardo,et al.  Asymptomatic pulmonary embolism secondary to cement leakage after vertebroplasty. , 2020, Reumatologia clinica.

[4]  R. Tubbs,et al.  Venous Drainage of the Lumbar Vertebral Bodies: An Anatomical Study with Application to Kyphoplasty, Vertebroplasty and Pedicle Screw Complications. , 2020, World neurosurgery.

[5]  C. Niu,et al.  Risk factors of neurological deficit and pulmonary cement embolism after percutaneous vertebroplasty , 2019, Journal of Orthopaedic Surgery and Research.

[6]  M. Kong,et al.  Clinical characteristics and management of cardiac and/or pulmonary cement embolus after percutaneous vertebroplasty: a single center experience. , 2019, Annals of translational medicine.

[7]  S. D’Errico,et al.  Fatal cardiac perforation and pulmonary embolism of leaked cement after percutaneous vertebroplasty. , 2019, Journal of forensic and legal medicine.

[8]  Jun Liu,et al.  Influence of vertebral bone mineral density on total dispersion volume of bone cement in vertebroplasty , 2019, Medicine.

[9]  Lifeng Lao,et al.  Bone cement distribution is a potential predictor to the reconstructive effects of unilateral percutaneous kyphoplasty in OVCFs: a retrospective study , 2018, Journal of Orthopaedic Surgery and Research.

[10]  M. Qi,et al.  The Optimal Volume Fraction in Percutaneous Vertebroplasty Evaluated by Pain Relief, Cement Dispersion, and Cement Leakage: A Prospective Cohort Study of 130 Patients with Painful Osteoporotic Vertebral Compression Fracture in the Thoracolumbar Vertebra. , 2018, World neurosurgery.

[11]  Publisher's Note , 2018, Anaesthesia.

[12]  Jian-zhong Jiang,et al.  Risk Factors for Cement Leakage After Vertebroplasty or Kyphoplasty: A Meta-Analysis of Published Evidence. , 2017, World neurosurgery.

[13]  Zihui Zhou,et al.  Is There a Dose–Response Relationship of Cement Volume With Cement Leakage and Pain Relief After Vertebroplasty? , 2016, Dose-response : a publication of International Hormesis Society.

[14]  Sang Pyung Lee,et al.  Appropriate Cement Volume in Vertebroplasty: A Multivariate Analysis with Short-Term Follow-Up , 2016, Korean journal of neurotrauma.

[15]  A. Ashour,et al.  Vertebral augmentation by kyphoplasty and vertebroplasty: 8 years experience outcomes and complications , 2016, Journal of craniovertebral junction & spine.

[16]  Jianting Chen,et al.  Risk factors for bone cement leakage in percutaneous vertebroplasty: a retrospective study of four hundred and eighty five patients , 2016, International Orthopaedics.

[17]  P. Jarzem,et al.  Pulmonary Artery Cement Embolism after a Vertebroplasty , 2015, Case reports in orthopedics.

[18]  D. Liang,et al.  [Correlation analysis of cement leakage with volume ratio of intravertebral bone cement to vertebral body and vertebral body wall incompetence in percutaneous vertebroplasty for osteoporotic vertebral compression fractures]. , 2014, Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery.

[19]  F. Cannizzaro,et al.  Asymptomatic Bone Cement Pulmonary Embolism after Vertebroplasty: Case Report and Literature Review , 2013, Case reports in surgery.

[20]  Liang Chen,et al.  Pulmonary Cement Embolism Associated with Percutaneous Vertebroplasty or Kyphoplasty: A Systematic Review , 2012, Orthopaedic surgery.

[21]  M. Reiser,et al.  CT fluoroscopy-guided percutaneous vertebroplasty in spinal malignancy: technical results, PMMA leakages, and complications in 202 patients , 2012, Skeletal Radiology.

[22]  C. Cox,et al.  Investigation of polymethylmethacrylate pulmonary embolus in a patient ten years following vertebroplasty. , 2011, Journal of radiology case reports.

[23]  D. Kallmes,et al.  Asymptomatic and Unrecognized Cement Pulmonary Embolism Commonly Occurs with Vertebroplasty , 2011, American Journal of Neuroradiology.

[24]  M. Raza Pulmonary Cement Embolism after Percutaneous Vertebroplasty in Osteoporotic Vertebral Compression Fractures: Incidence, Characteristics, and Risk Factors , 2010 .

[25]  Heung Sik Kang,et al.  Pulmonary cement embolism after percutaneous vertebroplasty in osteoporotic vertebral compression fractures: incidence, characteristics, and risk factors. , 2009, Radiology.

[26]  S. Ferguson,et al.  Vertebroplasty and Kyphoplasty: A Systematic Review of 69 Clinical Studies , 2006, Spine.

[27]  S Sawada,et al.  Percutaneous vertebroplasty for compression fracture: analysis of vertebral body volume by CT volumetry , 2005, Acta radiologica.

[28]  K. Ahrar,et al.  Pulmonary embolism of polymethyl methacrylate during percutaneous vertebroplasty and kyphoplasty. , 2004, AJR. American journal of roentgenology.

[29]  J. Theis,et al.  Pressurization of Vertebral Bodies During Vertebroplasty Causes Cardiovascular Complications: An Experimental Study in Sheep , 2003, Spine.

[30]  Christoph Fankhauser,et al.  Augmentation of mechanical properties in osteoporotic vertebral bones – a biomechanical investigation of vertebroplasty efficacy with different bone cements , 2001, European Spine Journal.

[31]  M. A. Glasby,et al.  AN EXPERIMENTAL STUDY IN SHEEP , 1994 .