Mitigation of saturation in dynamic voltage restorer connection transformers

During the transient period at the start of a voltage sag, a DVR injection transformer can experience a flux-linkage that is up to twice its nominal steady-state value. In order to prevent the transformers from saturating it is normal to choose a rating flux that is double that of the steady-state limit. An alternative method is to limit the flux-linkage during the transient switch-on period, thus preventing saturation. It is shown through both simulation and experimental results that an adaptive form factor can be applied to the DVR injected voltage, which minimizes the disturbance seen by a sensitive load, while at the same time preventing saturation. The proposed method removes the need for rating the series injection transformers for the DVR transient switch-on period, and therefore removes the redundancy normally associated with their steady state operation. In economic terms, this may reduce the total cost of a DVR system, thus making it a more attractive solution for voltage sag mitigation.

[1]  G. D. Marques,et al.  Four-wire current-regulated PWM voltage converter , 1998, IEEE Trans. Ind. Electron..

[2]  Math Bollen,et al.  Understanding Power Quality Problems: Voltage Sags and Interruptions , 1999 .

[3]  Mike Barnes,et al.  Software phase-locked loop applied to dynamic voltage restorer (DVR) , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).

[4]  R. S. Weissbach,et al.  Dynamic voltage compensation on distribution feeders using flywheel energy storage , 1999 .

[5]  G. Joos,et al.  Control algorithms for series static voltage regulators in faulted distribution systems , 1999, 30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321).

[6]  Kamal Al-Haddad,et al.  A review of active filters for power quality improvement , 1999, IEEE Trans. Ind. Electron..

[7]  V. Blasko,et al.  Operation of a phase locked loop system under distorted utility conditions , 1997 .

[8]  Hirofumi Akagi,et al.  The unified power quality conditioner: the integration of series- and shunt-active filters , 1998 .

[9]  C. S. Chang,et al.  Simulation and analysis of series voltage restorers (SVR) for voltage sag relief , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[10]  Nicholas Jenkins,et al.  Dynamic voltage restorer based on voltage-space-vector PWM control , 2001 .

[11]  C. Grigg,et al.  Predicting and preventing problems associated with remote fault clearing voltage dips , 1989, Conference Record. Industrial and Commercial Power Systems Technical Conference.