Calibration for realization errors of two-channel HFB ADC base on single analog filter architecture

The single analog filter (SAF) hybrid filter bank (HFB) ADC is presented in this paper. Base on SAF architecture, a calibration model is derived to integrate the analog filter's realization errors and channel mismatches errors. A two-channel SAF HFB ADC with 12-bit resolution and 200MHz sampling rate is implemented. The experimental results show that the average spurious-free dynamic range (SFDR) over the whole frequency spectrum enhanced from 35 dB to 88.3 dB when the proposed calibration method has been used.

[1]  Pierre Duhamel,et al.  Wideband, Bandpass, and Versatile Hybrid Filter Bank A/D Conversion for Software Radio , 2009, IEEE Transactions on Circuits and Systems I: Regular Papers.

[2]  J. Oksman,et al.  Modelling the imperfections of analog circuits using Second-Order Statistics , 2006 .