Assessment of registration accuracy during computer-aided oncologic limb-salvage surgery

PurposeComputer-aided surgery is used in musculoskeletal tumor procedures to improve the surgeon’s orientation to local anatomy during tumor resection. For the navigation system to function correctly, preoperative imaging (e.g., CT, MR) must be registered to the patient in the operating room. The goals of this study were (1) to directly quantify registration accuracy in computer-aided tumor surgery and (2) to validate the “system reported error” (SRE) of the navigation system.MethodsRegistration accuracy was evaluated in eight bone sarcoma cases by determining the location of the anatomical paired-points used for registration following surface matching. Coordinates of specific intraoperative post-registration points were compared with the corresponding coordinates in preoperative CT scans to determine the measurement error (ME).ResultsThe mean difference between post-registration points and planned registration points was $$12.21 \pm 6.52\,\hbox {mm}$$12.21±6.52mm, significantly higher than the mean SRE ($$0.68 \pm 0.15\,\hbox {mm}$$0.68±0.15mm; $$p=0.002$$p=0.002; 95 % CI 6.11–16.96 mm). The SRE poorly correlated with the calculated ME ($$R^2=0.040$$R2=0.040). Anatomical paired-point registration with surface matching results in a substantial shift in the post-registration coordinates of the same paired-points used for registration, and this shift is not represented by the SRE.ConclusionThe SRE of a surgical navigation system was poorly correlated with direct measurements obtained in musculoskeletal tumor surgery. Improvement in registration accuracy is needed to better navigate tumor boundaries and ensure clear margins while maximally preserving the unaffected tissues and reducing operative morbidity.

[1]  K. Buehler,et al.  Computer assisted navigation in total knee arthroplasty: comparison with conventional methods. , 2005, The Journal of arthroplasty.

[2]  Han-Soo Kim,et al.  Computer-assisted sacral tumor resection. A case report. , 2008, The Journal of bone and joint surgery. American volume.

[3]  Guoyan Zheng,et al.  i) Registration techniques for computer navigation , 2007 .

[4]  K S Leung,et al.  Precision tumour resection and reconstruction using image-guided computer navigation. , 2007, The Journal of bone and joint surgery. British volume.

[5]  Norbert Suhm,et al.  Computer aided long bone fracture treatment. , 2004, Injury.

[6]  L. Ritacco,et al.  Multiplanar osteotomies guided by navigation in chondrosarcoma of the knee. , 2013, Orthopedics.

[7]  Hiroaki Nakamura,et al.  Navigation-assisted Surgery for Bone and Soft Tissue Tumors With Bony Extension , 2012, Clinical orthopaedics and related research.

[8]  Christian Krettek,et al.  New Indications for Computer-Assisted Surgery: Tumor Resection in the Pelvis , 2004, Clinical orthopaedics and related research.

[9]  Frank Langlotz Potential pitfalls of computer aided orthopedic surgery. , 2004, Injury.

[10]  Yann Nguyen,et al.  Use of anatomic or invasive markers in association with skin surface registration in image-guided surgery of the temporal bone , 2009, Acta oto-laryngologica.

[11]  M. C. M. Wong,et al.  Computer assisted pelvic tumor resection and reconstruction with a custom-made prosthesis using an innovative adaptation and its validation , 2007, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[12]  Han-Soo Kim,et al.  Joint‐preserving limb salvage surgery under navigation guidance , 2009, Journal of surgical oncology.

[13]  David Cheong,et al.  Computer-assisted navigation and musculoskeletal sarcoma surgery. , 2011, Cancer control : journal of the Moffitt Cancer Center.

[14]  L. Ritacco,et al.  Accuracy of 3-D planning and navigation in bone tumor resection. , 2013, Orthopedics.

[15]  João Manuel R S Tavares,et al.  Medical image registration: a review , 2014, Computer methods in biomechanics and biomedical engineering.

[16]  Musa Citak,et al.  Computer aided tumor resection in the pelvis. , 2004, Injury.

[17]  Kwok Chuen Wong,et al.  Computer-assisted Tumor Surgery in Malignant Bone Tumors , 2013, Clinical orthopaedics and related research.

[18]  O Cartiaux,et al.  Registration accuracy in computer-assisted pelvic surgery , 2009, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[19]  H. Staecker,et al.  Making Image Guidance Work: Understanding Control of Accuracy , 2003, The Annals of otology, rhinology, and laryngology.

[20]  B. Klatt,et al.  Computer-Assisted Navigation—Total Knee Arthroplasty , 2012 .

[21]  J. Kretz Cancer Control , 1942, Nature.

[22]  H Labelle,et al.  Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. , 2000, Spine.

[23]  R. Verma,et al.  Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screws , 2010, European Spine Journal.

[24]  N. Schep,et al.  Computer assisted orthopaedic and trauma surgery. State of the art and future perspectives. , 2003, Injury.

[25]  Jing Li,et al.  Irregular osteotomy in limb salvage for juxta‐articular osteosarcoma under computer‐assisted navigation , 2012, Journal of Surgical Oncology.

[26]  Alireza Ahmadian,et al.  A projected landmark method for reduction of registration error in image-guided surgery systems , 2015, International Journal of Computer Assisted Radiology and Surgery.

[27]  R. Marmulla,et al.  Image-to-patient registration techniques in head surgery. , 2006, International journal of oral and maxillofacial surgery.

[28]  D. Springfield Surgery for MSK tumors: 1971–2011 , 2011, Skeletal Radiology.

[29]  Olivier Cartiaux,et al.  Computer-Assisted Resection and Reconstruction of Pelvic Tumor Sarcoma , 2010, Sarcoma.

[30]  N. Sugano Computer-Assisted Orthopaedic Surgery and Robotic Surgery in Total Hip Arthroplasty , 2013, Clinics in orthopedic surgery.

[31]  R. Phillips,et al.  ii) The accuracy of surgical navigation for orthopaedic surgery , 2007 .

[32]  Bruno Dehez,et al.  Surgical inaccuracy of tumor resection and reconstruction within the pelvis: An experimental study , 2008, Acta orthopaedica.

[33]  B. Parashar,et al.  Unresectable Retiform Hemangioendothelioma Treated with External Beam Radiation Therapy and Chemotherapy: A Case Report and Review of the Literature , 2010, Sarcoma.

[34]  P. London Injury , 1969, Definitions.

[35]  T. Laine,et al.  Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients , 2000, European Spine Journal.